Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2866611
PHOENIX CONTACTNot available

TRIO-UPS/1AC/24DC/ 5 - Uninterruptible power supply

Uninterruptible power supply with integrated power supply unit. For lead AGM energy storage of type MINI-BAT/24/DC/1.3 AH, QUINT-BAT/24DC 3.4 AH … 12 AH nominal capacity. Input: 1-phase, output: 24VDC / 5A. Screw connection technology
Product Code: 2866611
Partner cod.: 2866611
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Input dataDC operation
Input voltage: 24 VDC
Nominal input voltage range: 100 VAC ... 240 VAC
Input voltage range: 85 VAC ... 264 VAC (Derating < 90 V AC: 2.5%V)
100 VDC ... 350 VDC (UL508: 100 ... 250 V)
Input voltage range AC: 85 VAC ... 264 VAC (Derating < 90 V AC: 2.5%V)
Input voltage range DC: 100 VDC ... 350 VDC (UL508: 100 ... 250 V)
Voltage type of supply voltage: AC/DC
Inrush current: < 44 A (< 1.3 A2s)
Inrush current integral (I2t): < 1.3 A2s
AC frequency range: 45 Hz ... 65 Hz
Frequency range DC: 0 Hz
Mains buffering time: see diagram
Buffer period: 20 min. (5A)
Rotary selector switch: adjustable: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; PC-Mode
Current consumption: 0.95 A (230 V AC)
1.1 A (230VAC, maximum)
1.7 A (120VAC)
1.8 A (120VAC, maximum)
Protective circuit: Transient surge protection; Varistor
Power factor (cos phi): approx. 0.5
Typical response time: 150 ms (230 V AC)
200 ms (120VAC)
Input fuse: 6.3 A (slow-blow, internal)
Permissible backup fuse: B6 B10 B16
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Output dataEfficiency: > 88 % (230 V AC, network operation)
> 86 % (120VAC, network operation)
> 86 % (Battery operation)
Nominal output voltage: 24 VDC
Setting range of the output voltage (USet): 22.5 VDC ... 29.5 VDC (Network operation; in the buffer mode, dependent on the battery voltage of 27.9 V DC ... 19.2 V DC)
Nominal output current (IN): 5 A (-25°C...55°C)
Output current limit: max. 6 A (Mains operation)
Bridging time: 3600 s
Derating: 55°C ... 70°C (2.5%/K)
Feedback voltage resistance: 35 VDC
Protection against overvoltage at the output (OVP): < 35 VDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
Residual ripple: < 10 mVPP
Output power: 120 W
Nominal power: 120 W
Peak switching voltages nominal load: < 25 mVPP
Power dissipation: 16 W (230 V AC)
20 W (120VAC)
2 W (Maximum, no load)
4 W (Maximum, nominal load)
Rise time: < 100 ms
Connection in parallel: yes, 2
Connection in series: No
Mains operation
Nominal output voltage: 24 VDC
Output voltage range: 22.5 VDC ... 29.5 VDC
Nominal output current (IN): 5 A
Battery operation
Nominal output voltage: 24 VDC
Output voltage range: 19.2 VDC ... 27.6 VDC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN): 5 A
Signal
Output voltage: + 24 V
Signal: Alarm
Output description: Transistor switching output
Maximum switching voltage: ≤ 24 V
Output voltage: 24 V
Continuous load current: ≤ 200 mA
Signal: Battery charge
Output description: Transistor switching output
Maximum switching voltage: ≤ 24 V
Output voltage: 24 V
Continuous load current: ≤ 200 mA
Signal: Battery mode
Output description: Transistor switching output
Maximum switching voltage: ≤ 24 V
Output voltage: 24 V
Continuous load current: ≤ 200 mA
Energy storageEnd-of-charge voltage: 25 VDC ... 30 VDC (Default 27.6 V DC)
Charging current: 1.5 A
Deep discharge protection: 18 VDC ... 21 VDC (Default 19.2 V DC)
Memory medium: external, battery 1.3Ah / 3.4Ah / 7.2Ah / 12Ah
Battery presence check/time interval: 60 s
Quality check of battery: 4 h ... 200 h (Default 12 h)
Charge characteristic curve: I/U characteristic curve
IQ technology: no
Temperature compensation: 0 mV/K ... 200 mV/K (42 mV/K by default)
Alarm signaling threshold: 18 VDC ... 30 VDC (Default 20.4 V DC)
Network management: No
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 8 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Signal
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
InterfacesInterface: IFS (Interface system data port)
SignalingTypes of signaling: LED
Signal output
Status display: Green LED
Note on status display: Mains voltage OK: Green LED, static at
Signal output: Alarm
Status display: Alarm
Note on status display: Red LED, static at
Signal output: Battery charge
Status display: Battery (battery charge) is being charged
Note on status display: Yellow LED, flashing
Signal output: Battery mode
Status display: Battery operation (Battery Mode)
Note on status display: LED yellow, static at
Electrical propertiesInsulation voltage input/output: 4 kV (type test)
2 kV (routine test)
Insulation voltage output / PE: 500 VDC (routine test)
Insulation voltage input / PE: 2 kV AC (type test)
2 kV AC (routine test)
Product propertiesProduct type: DC UPS
IQ technology: no
MTBF (IEC 61709, SN 29500): > 596000 h (40°C)
Insulation characteristics
Protection class: I
Degree of pollution: 2
DimensionsWidth: 60 mm
Height: 130 mm
Depth: 118 mm
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 50 mm / 50 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: horizontally 0mm, vertically 50mm
Mounting position: horizontal DIN rail NS 35, EN 60715
Material specificationsHousing material: Metal
Aluminum (AlMg3) / sheet steel, zinc-plated
Type of housing: Aluminum (AlMg3) + zinc-plated sheet steel, enclosed
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport): -40°C ... 80°C
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: EN50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV)
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard - Electrical safety: EN60950-1/VDE0805 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment: EN50178
Standard – Safety extra-low voltage: EN60950-1 (SELV)
EN60204 (PELV)
Standard - Safe isolation: DINVDE0100-410
ApprovalsShipbuilding approval: DNVGL(EMCB)
UL approvals: UL/C-UL listed UL508
UL/C-UL Recognized UL60950-1
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 55011 (EN 55022)
Electrostatic discharge
Standards/regulations: EN61000-4-2
Housing: Level 3
Electrostatic discharge​
Contact discharge: 6 kV
Discharge in air: 8 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 2 GHz
Test field strength: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (level 4 - asymmetrical: conductor to ground)
Output: 2 kV (level 4 - asymmetrical: conductor to ground)
Signal: 1 kV (level 4 - asymmetrical: conductor to ground)
Comments: Criterion B
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
I/O/S: Level 3
Frequency range: 10 kHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Voltage dips
Standards/regulations: EN61000-4-11
Emitted interference
Standards/regulations: EN61000-6-3
Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassB, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential
Technical Specs
ECLASSECLASS-11.0: 27040705
ECLASS-12.0: 27040705
ECLASS-13.0: 27040705
ETIMETIM 9.0: EC000382
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00040.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_01611.pdf

Data_sheet_03649.pdf

Data_sheet_03112.pdf

Manufacturer_declaration_03022.pdf

Manufacturer_declaration_04715.pdf

Manufacturer_declaration_05509.pdf

Manufacturer_declaration_15327.pdf

Package_slip_02469.pdf

Technical_drawing_39058.pdf

Various_00006.pdf