QUINT-UPS/ 24DC/ 24DC/20 - Uninterruptible power supply

Uninterruptible power supply with IQ technology for DIN rail mounting, input: 24 V DC, output: 24 V DC/20 A, including mounted universal DIN rail adapter UTA 107/30
Product Code: 2320238
Partner cod.: 2320238
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Input dataDC operation
Input voltage: 24 VDC
Nominal input voltage range: 24 VDC
Input voltage range: 18 VDC ... 30 VDC
Input voltage range DC: 18 VDC ... 30 VDC
Voltage type of supply voltage: DC
Buffer period: 1 h (With battery module 38 AH)
Current consumption: 32.9 A (maximum, mains operation)
10.5 mA (No load, mains operation)
6.9 A (Charging, mains operation)
Fixed backup threshold: ≤ 22 VDC
Variable connect threshold: 1 V/0.1 s
Output dataEfficiency: > 98 % (Mains operation, with charged energy storage)
98 % (Battery operation)
Nominal output voltage: 24 VDC
Output voltage range: 18 VDC ... 30 VDC
Nominal output current (IN): 20 A (-25°C...50°C)
Output current limit: In mains mode according to connected upstream current limiting device
> 27 A (Battery operation)
Bridging time: 7200 s
Derating: 60°C ... 70°C (2.5%/K)
Output power: 480 W
Power dissipation: 2.7 W (Mains operation)
7.65 W (Mains operation)
3.19 W (Battery operation)
9.35 W (Battery operation)
Connection in parallel: yes, up to 2 modules with redundancy module
2 (Devices)
Connection in series: No
no
Mains operation
Nominal output voltage: 24 VDC
Output voltage range: 18 VDC ... 30 VDC
Nominal output current (IN): 20 A (-25°C...60°C)
POWER BOOST (IBoost): 26 A (-25°C...40°C)
Selective Fuse Breaking (ISFB): 120 A (-25°C...60°C)
Duration: 12 ms (SFB technology)
Battery operation
Nominal output voltage: 24 VDC
Output voltage range: 19.2 VDC ... 27.6 VDC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN): 20 A (-25°C...60°C)
POWER BOOST (IBoost): 27 A (-25°C...40°C)
Selective Fuse Breaking (ISFB): 120 A (-25°C...60°C)
Duration: 15 ms (SFB technology)
Signal: Alarm
Output description: Relay (floating)
Maximum switching voltage: ≤ 30 V AC/DC
Continuous load current: ≤ 100 mA
Signal: Battery charge
Output description: Relay (floating)
Maximum switching voltage: ≤ 30 V AC/DC
Output voltage: 24 V
Continuous load current: ≤ 100 mA
Signal: Battery mode
Output description: Relay (floating)
Maximum switching voltage: ≤ 30 V AC/DC
Output voltage: 24 V
Continuous load current: ≤ 100 mA
Energy storageNominal voltage UN: 24 VDC
End-of-charge voltage: 24 VDC ... 29 VDC (temperature compensated)
Charging current: 0.2 A ... 5 A
Nominal capacity range: 3 Ah ... 200 Ah
Battery presence check/time interval: 1 min.
Battery presence check (cyclic): 60 s
IQ technology: Yes
Temperature compensation: 42 mV/K (preset)
Temperature compensation (preset): 42 mV/K
Network management: Yes
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 6 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 4 mm²
Conductor cross section AWG min.: 12
Conductor cross section AWG max.: 10
Stripping length: 8 mm
Screw thread: M4
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 6 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 4 mm²
Conductor cross section AWG min.: 12
Conductor cross section AWG max.: 10
Stripping length: 8 mm
Screw thread: M4
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Signal
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Screw thread: M4
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
InterfacesInterface: IFS (Interface system data port)
SignalingTypes of signaling: LED
Relay contact
Interface/software
Signal output
Signalization designation: Power In OK
Status display: LED
Note on status display: Static to
Signal output: Switching output
Signalization designation: Alarm
Status display: LED
Note on status display: Static to
Color: red
Signal output: Switching output​
Signalization designation: Battery charge
Status display: LED bar graph
Note on status display: dynamic
Color: green/red
Signal output: Switching output​​
Signalization designation: Battery mode
Status display: LED
Note on status display: Static to
Color: yellow
Electrical propertiesInsulation voltage input/output: 500 VDC
Insulation voltage input, output / housing: 750 VDC
Product propertiesProduct type: DC UPS
Product family: QUINTUSV
IQ technology: Yes
MTBF (IEC 61709, SN 29500): > 500000 h (40°C)
Insulation characteristics
Protection class: III
Life expectancy (electrolytic capacitors)
Time: 195013 h
DimensionsWidth: 40 mm
Height: 130 mm
Depth: 125 mm
Installation dimensions
Installation distance right/left: 5 mm / 5 mm
Installation distance top/bottom: 50 mm / 50 mm
Alternative assembly
Width: 123 mm
Height: 130 mm
Depth: 43 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: horizontal 5mm, vertical 50mm
Mounting position: horizontal DIN rail NS 35, EN 60715
Material specificationsHousing material: Metal
Steel sheet, zinc-plated
Type of housing: Aluminum (AlMg3)
Hood version: Galvanized sheet steel, free from chrome (VI)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g tv = 90 min.
Standards and regulationsRail applications: EN50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV)
Standard - Electrical safety: EN60950-1/VDE0805 (SELV)
ApprovalsUL approvals: UL Listed UL508
UL/C-UL Recognized UL60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 15 kV (Test Level 4)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 3 GHz
2 GHz ... 3 GHz
Test field strength: 20 V/m
10 V/m
3 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 2 kV (Test Level 3 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Signal: 2 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output: 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Emitted interference
Standards/regulations: EN61000-6-3
Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassB, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Technical Specs
ECLASSECLASS-11.0: 27040705
ECLASS-13.0: 27040705
ECLASS-12.0: 27040705
ETIMETIM 9.0: EC000382
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00040.pdf

Approvals_00041.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01194.pdf

Approvals_01291.pdf

Approvals_01296.pdf

Approvals_01317.pdf

Approvals_01608.pdf

Data_sheet_03112.pdf

Data_sheet_03114.pdf

Manual_00124.pdf

Manufacturer_declaration_03036.pdf

Manufacturer_declaration_04610.pdf

Manufacturer_declaration_05510.pdf

Manufacturer_declaration_14301.pdf

Package_slip_02097.pdf

Package_slip_02377.pdf

Package_slip_02378.pdf

Technical_drawing_37395.pdf

Various_00006.pdf