Industrial Automation
Input data | AC operation Nominal input voltage range: 100 VAC ... 240 VAC Input voltage range: 85 VAC ... 264 VAC 95 VDC ... 250 VDC Input voltage range AC: 85 VAC ... 264 VAC Input voltage range DC: 95 VDC ... 250 VDC Voltage type of supply voltage: AC/DC Inrush current: < 15 A (typical) Inrush current integral (I2t): < 0.6 A2s AC frequency range: 45 Hz ... 65 Hz Frequency range DC: 0 Hz Mains buffering time: typ. 25 ms (120VAC) typ. 140 ms (230 V AC) Current consumption: 0.5 A (120VAC) 0.3 A (230 V AC) Nominal power consumption: 72.1 VA Protective circuit: Transient surge protection; Varistor Power factor (cos phi): 0.57 Typical response time: < 0.5 s Input fuse: 3.15 A (slow-blow, internal) Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K) |
Output data | Efficiency: > 80 % (for 230 V AC and nominal values) Output characteristic: U/I Nominal output voltage: 5 VDC ±1% Setting range of the output voltage (USet): 4 VDC ... 6.5 VDC (> 5VDC, constant capacity restricted) Output current Imax: 11.5 A Nominal output current (IN): 6.5 A (-25°C...55°C) 7.1 A (-25°C...40°C permanent) Derating: 55°C ... 70°C (2.5%/K) Feedback voltage resistance: ⤠10 VDC Protection against overvoltage at the output (OVP): < 10 VDC Control deviation: < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple: < 50 mVPP (20MHz) Output power: 32.5 W Peak switching voltages nominal load: < 40 mVPP (20MHz) Maximum no-load power dissipation: < 0.4 W Power loss nominal load max.: 8.1 W Rise time: < 0.5 s (UOUT (10 % ... 90 %)) Connection in parallel: yes, for redundancy and increased capacity Connection in series: yes |
Connection data | Input Connection method: Screw connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 12 Stripping length: 6.5 mm Screw thread: M3 Tightening torque, min: 0.5 Nm Tightening torque max: 0.6 Nm Output Connection method: Screw connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 12 Stripping length: 6.5 mm Screw thread: M3 Tightening torque, min: 0.5 Nm Tightening torque max: 0.6 Nm |
Signaling | Types of signaling: LED Operating voltage display: Green LED Signal output: LED status indicator Signalization designation: DC OK, active Status display: "DC OK" LED green Note on status display: UOUT > 3.7 V: LED on |
Electrical properties | Number of phases: 1.00 Insulation voltage input/output: 4 kV AC (type test) 3.75 kV AC (routine test) 3.75 kV AC (routine test) 4 kV AC (type test) Insulation voltage output / PE: 500 VDC (routine test) Insulation voltage input / PE: 3.5 kV AC (type test) 2 kV AC (routine test) |
Product properties | Product type: Power supply Product family: STEPPOWER MTBF (IEC 61709, SN 29500): > 1111000 h (40°C) Insulation characteristics Protection class: II (in closed control cabinet) Overvoltage category: III Degree of pollution: 2 |
Dimensions | Width: 72 mm Height: 90 mm Depth Device depth (DIN rail mounting): 55 mm (Device depth (DIN rail mounting)) Horizontal pitch: 4 Div. Installation dimensions Installation distance right/left: 0 mm / 0 mm Installation distance top/bottom: 30 mm / 30 mm |
Mounting | Mounting type: DIN rail mounting Assembly instructions: alignable: 0mm horizontally, 30mm vertically Mounting position: horizontal DIN rail NS 35, EN 60715 With protective coating: No |
Material specifications | Housing material: Plastic Polycarbonate Foot latch material: POM (Polyoxymethylene) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K) Ambient temperature (storage/transport): -40°C ... 85°C Climatic class: 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation): ⤠95 % (at 25°C, non-condensing) Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and regulations | Rail applications: EN50121-4 Standard â Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV) Standard â Limitation of mains harmonic currents: EN61000-3-2 Standard - Electrical safety: IEC 62368-1(SELV) Standard â Protection against shock currents, basic requirements for protective separation in electrical equipment: EN50178 Standard â Safety extra-low voltage: IEC 62368-1 (SELV) und EN60204-1 (PELV) Standard - Safe isolation: DINVDE0100-410 Standard - Safety of transformers: EN61558-2-16 |
Approvals | CSA: CSA-C22.2 No.107.1-01 Shipbuilding approval: DNVGL(EMCB)ABS, NK UL approvals: UL/C-UL listed UL508 UL/C-UL Recognized UL60950-1 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A (Hazardous Location) Conformity/Approvals SIL in accordance with IEC 61508: 0 |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC EMC requirements for noise emission: EN61000-6-3 EN61000-6-4 EMC requirements for noise immunity: EN61000-6-1 EN61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: 6 kV (Test Level 3) Discharge in air: 8 kV (Test Level 3) Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 2 GHz 2 GHz ... 3 GHz Test field strength: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 4 kV (Test Level 4 - asymmetrical) Output: 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: EN61000-4-5 Input: 2 kV (Test Level 3 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 2 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 10 kHz ... 15 kHz 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 3 V (Test Level 2) 10 V (Test Level 3) Voltage dips Standards/regulations: EN61000-4-11 Emitted interference Standards/regulations: EN61000-6-3 Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) classB used in industry and residential area / EMC1 Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) class B used in industry and residential area / EMC 1 |
ECLASS | ECLASS-11.0: 27040701 ECLASS-12.0: 27040701 ECLASS-13.0: 27040701 |
ETIM | ETIM 9.0: EC002540 |
UNSPSC | UNSPSC 21.0: 39121000 |