Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2900162
PHOENIX CONTACTNot available

FLKM-2KS50/BFI/MKDS/CS - Passive module

Termination board for Yokogawa ADV151, ADV161, ADV551 and ADV561 I/O modules with a fuse for cable protection (5x20) and fuse failure display (LED) per channel. Redundant system connection.
Product Code: 2900162
Partner cod.: 2900162
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Interface module
No. of channels: 32
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Functional insulation
Insulation characteristics​
Insulation: Functional insulation
Overvoltage category: II
Pollution degree: 2
Electrical propertiesNo. of channels: 32
Nominal voltage UN: 24 VDC
19.2 VDC ... 26.4 VDC
Max. current carrying capacity per branch: 100 mA (observe derating)
Max. total current of all branches: 4 A (observe derating)
Rated insulation voltage: 50 VDC
Rated surge voltage: 0.5 kV
Supported controller YOKOGAWA CS3000 CentumVP
Suitable I/O card: ADV151
ADV161
ADV551
ADV561
Supported controller YOKOGAWA STARDOM
Suitable I/O card: NFDV151
NFDV161
NFDV551
NFDV561
Output dataContact switching type: 1 N/O contact
Type of switch contact: Double contact
Contact material: AgNi, 5 µm hard gold-plated
Maximum switching voltage: < 25 VAC
48 VDC
Limiting continuous current: 1 A
Min. switching current: 1 mA
Interrupting rating (ohmic load) max.: 24 W (24VDC)
48 W (48VDC)
25 VA (25VAC)
Mechanical service life: approx. 2x 107 cycles
Connection dataField level
Connection method: Screw connection
Conductor cross section rigid: 0.2 m² ... 4 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
Controller level
Connection method: Yokogawa KS-compatible
Number of connections: 2
Number of positions: 50
Note: Usable system cables: Phoenix Contact YUC50, Yokogawa AKB331
Tightening torque: 0.5 Nm
SignalingStatus display: LED red
Status display present: Yes, if the fuse fails
Operating voltage display: Green LED
DimensionsItem dimensions
Width: 343.1 mm
Height: 111.9 mm
Depth: 65.15 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP00
Ambient temperature (operation): -20°C ... 65°C
Ambient temperature (storage/transport): -20°C ... 70°C
Altitude: ≤ 2000 m
Standards and regulationsStandards/regulations: DINEN50178
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
NotesGeneral: Voltage monitoring on the module does not work in combination with upstream HESILED fuse terminal blocks with integrated LED display.
Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
No additional touch protection is required when using a SELV/PELV voltage (≤ 25VAC or 60VDC).
Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e.g. partition plates).
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.
Technical Specs
ECLASSECLASS-11.0: 27141152
ECLASS-12.0: 27141152
ECLASS-13.0: 27141152
ETIMETIM 8.0: EC002780
UNSPSCUNSPSC 21.0: 39121400