Industrial Automation
FLKM-2KS50/BFI/MKDS/CS - Passive module
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | Product type: Interface module No. of channels: 32 Operating mode: 100% operating factor Insulation characteristics Insulation: Functional insulation Insulation characteristicsâ Insulation: Functional insulation Overvoltage category: II Pollution degree: 2 |
Electrical properties | No. of channels: 32 Nominal voltage UN: 24 VDC 19.2 VDC ... 26.4 VDC Max. current carrying capacity per branch: 100 mA (observe derating) Max. total current of all branches: 4 A (observe derating) Rated insulation voltage: 50 VDC Rated surge voltage: 0.5 kV Supported controller YOKOGAWA CS3000 CentumVP Suitable I/O card: ADV151 ADV161 ADV551 ADV561 Supported controller YOKOGAWA STARDOM Suitable I/O card: NFDV151 NFDV161 NFDV551 NFDV561 |
Output data | Contact switching type: 1 N/O contact Type of switch contact: Double contact Contact material: AgNi, 5 µm hard gold-plated Maximum switching voltage: < 25 VAC 48 VDC Limiting continuous current: 1 A Min. switching current: 1 mA Interrupting rating (ohmic load) max.: 24 W (24VDC) 48 W (48VDC) 25 VA (25VAC) Mechanical service life: approx. 2x 107 cycles |
Connection data | Field level Connection method: Screw connection Conductor cross section rigid: 0.2 m² ... 4 mm² Conductor cross section flexible: 0.2 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 Controller level Connection method: Yokogawa KS-compatible Number of connections: 2 Number of positions: 50 Note: Usable system cables: Phoenix Contact YUC50, Yokogawa AKB331 Tightening torque: 0.5 Nm |
Signaling | Status display: LED red Status display present: Yes, if the fuse fails Operating voltage display: Green LED |
Dimensions | Item dimensions Width: 343.1 mm Height: 111.9 mm Depth: 65.15 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP00 Ambient temperature (operation): -20°C ... 65°C Ambient temperature (storage/transport): -20°C ... 70°C Altitude: ⤠2000 m |
Standards and regulations | Standards/regulations: DINEN50178 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |
Notes | General: Voltage monitoring on the module does not work in combination with upstream HESILED fuse terminal blocks with integrated LED display. Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. No additional touch protection is required when using a SELV/PELV voltage (⤠25VAC or 60VDC). Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e.g. partition plates). For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
ECLASS | ECLASS-11.0: 27141152 ECLASS-12.0: 27141152 ECLASS-13.0: 27141152 |
ETIM | ETIM 8.0: EC002780 |
UNSPSC | UNSPSC 21.0: 39121400 |
Description other products