Product properties | Product type: Relay Module Product family: PLC-INTERFACE Installation location: Attached to the vehicle body Application: Railway applications Operating mode: 100% operating factor Mechanical service life: approx. 3x 107 cycles Insulation characteristics Insulation: Basic insulation Insulation characteristicsâ Insulation: Basic insulation Overvoltage category: III Pollution degree: 2 |
Electrical properties | Maximum power dissipation for nominal condition: 0.5 W Test voltage (Winding/contact): 5 kVrms (50Hz, 1min., winding/contact) Test voltage (Changeover contact/changeover contact): 2.5 kVrms (50Hz, 1min., changeover contact/changeover contact) Rated insulation voltage: 250 VAC Rated surge voltage: 6 kV |
Input data | Coil side Nominal input voltage UN: 110 VDC Input voltage range: 77 VDC ... 137.5 VDC Input voltage range in reference to UN: 0.7 ... 1.25 Drive and function: monostable Drive (polarity): polarized Typical input current at UN: 4.5 mA Typical response time: 5 ms Typical release time: 11 ms Coil voltage: 60 VDC Protective circuit: Bridge rectifier Surge protection; Freewheeling diode RCZ filter Wide-range electronics Operating voltage display: Yellow LED |
Output data | Switching Contact switching type: 2 changeover contacts Type of switch contact: Single contact Contact material: AgNi, hard gold-plated Maximum switching voltage: 30 VAC 36 VDC Minimum switching voltage: 100 mV (10mA) Limiting continuous current: 50 mA Maximum inrush current: 50 mA Min. switching current: 1 mA (24V) Interrupting rating (ohmic load) max.: 1.2 W (at 24 V DC) Switching: when the gold layer is destroyed Note: the following values are applicable if a gold layer is destroyed Maximum switching voltage: 250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250V (L1, L2, L3) between identical terminal blocks in adjacent modules.) Minimum switching voltage: 12 V AC/DC Limiting continuous current: 2x 6 A (see derating curve) Maximum inrush current: 15 A (300ms) Min. switching current: 10 mA Interrupting rating (ohmic load) max.: 140 W (at 24 V DC) 100 W (at 48 V DC) 60 W (at 60 V DC) 44 W (at 110 V DC) 60 W (at 220 V DC) 1500 VA (for 250 V AC) Switching capacity: 2 A (at 24 V, DC13) 0.2 A (at 110 V, DC13) 0.2 A (at 250 V, DC13) 2 A (at 24 V, AC15) 2 A (at 120 V, AC15) 2 A (at 250 V, AC15) |
Connection data | Connection method: Push-in connection Stripping length: 10 mm Conductor cross section rigid: 0.14 mm² ... 2.5 mm² Conductor cross section flexible: 0.14 mm² ... 2.5 mm² 0.2 mm² ... 2.5 mm² (Single ferrule) 2x 0.5 mm² ... 1 mm² (TWIN ferrule) Conductor cross section AWG: 26 ... 14 |
Dimensions | Width: 14 mm Height: 80 mm Depth: 94 mm |
Material specifications | Flammability rating according to UL 94: V0 (Housing) |
Environmental and real-life conditions | Ambient conditions Degree of protection (Relay base): IP20 (Relay base) Degree of protection (Relay): RT III (Relay) Ambient temperature (operation): -40°C ... 70°C (Temperature class TX) Ambient temperature (storage/transport): -40°C ... 85°C |
Approvals | CE Certificate: CE-compliant UKCA Certificate: UKCA-compliant Shipbuilding approval Certificate: TAE0000196 Corrosive gas test Identification: ISA-S71.04. G3 Harsh Group EN60068-2-60 DNV GL data Temperature: D Humidity: A Vibration: B/C EMC: B Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive Electromagnetic compatibility: Conformance with EMC directive |
Standards and regulations | Standards/regulations: IEC 60947-5-1 EN50155 (VDE0115 part 200) EN61373 EN50121 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |
ECLASS | ECLASS-11.0: 27371601 ECLASS-12.0: 27371601 ECLASS-13.0: 27371601 |
ETIM | ETIM 9.0: EC001437 |
UNSPSC | UNSPSC 21.0: 39122300 |