PHOENIX CONTACT 2901428
PHOENIX CONTACTNot available

PSR-SCP-230UC/ESAM4/3X1/1X2/B - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL3 or Cat.4, PLe in accordance with ENISO13849, 1- or 2-channel operation, 3enabling current paths, nominal input voltage: 230VAC/DC, plug-in screw terminal blocks
Product Code: 2901428
Partner cod.: 2901428
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Emergency stop
Safety door
Mechanical service life: approx. 107 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Electrical propertiesMaximum power dissipation for nominal condition: 2.88 W
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VAC
Rated surge voltage/insulation: 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)
Input dataGeneral
Rated control circuit supply voltage US: 230 V AC/DC -15% / +10%
Power consumption at US: 2 W
Rated control supply current IS: 22 mA
Voltage at input/start and feedback circuit: ~ 24 VDC
Typical response time: 40 ms (man. start)
Typ. starting time with Us: 330 ms (when controlled via A1)
Typical release time: 150 ms (when controlled via A1)
20 ms (when controlled via S11/S12 and S21/S22)
Concurrence: ∞
Recovery time: 1 s
Maximum switching frequency: 0.5 Hz
Protective circuit: Surge protection; Varistor 275 VRMS (A1-A2)
Surge protection; Varistor
Max. permissible overall conductor resistance: 50 Ω
Output dataContact switching type: 3 enabling current paths
1 signaling current path
Contact material: AgSnO2, + 0.2 µm Au
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 10 V AC/DC
Limiting continuous current: 6 A (Enabling current paths)
5 A (Signaling current path)
Maximum inrush current: 6 A
Inrush current, minimum: 10 mA
Sq. Total current: 72 A2 (ITH2 = I12 + I22 + I32)
Interrupting rating (ohmic load) max.: 144 W (24 V DC, τ = 0 ms)
230 W (48 V DC, τ = 0 ms)
68 W (110 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
2000 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load): 48 W (24VDC, τ=40ms)
40 W (48 V DC, τ = 40 ms)
35 W (110 V DC, τ = 40 ms)
33 W (220 V DC, τ = 40 ms)
Switching capacity min.: 100 mW
Switching capacity (360/h cycles): 6 A (24VDC)
5 A (230 V AC)
Switching capacity (3600/h cycles): 3 A (24V (DC13))
3 A (230 V (AC 15))
Output fuse: 10 A gL/gG NEOZED (Enabling current paths)
6 A gL/gG NEOZED (Signaling current path)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
SignalingStatus display: 3 x green LED
Operating voltage display: 1 x green LED
DimensionsWidth: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 4
Performance level (PL): e
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -25°C ... 55°C
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsConformity/Approvals
Conformance: CE-compliant
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60664-1
MountingMounting type: DIN rail mounting
Mounting position: any
Connection method: Screw connection
Technical Specs
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Description
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 230 V AC/DC, plug-in screw terminal blocks
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00247.pdf

Approvals_00807.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Certification_00214.pdf

Certification_00335.pdf

Data_sheet_03737.pdf

Manufacturer_declaration_00632.pdf

Manufacturer_declaration_02111.pdf

Manufacturer_declaration_15631.pdf

Package_slip_01868.pdf

Technical_drawing_39520.pdf