PHOENIX CONTACT 2902647
PHOENIX CONTACTNot available

RIF-T3-24UC - Timer module

Plug-in module for extending a relay module to create a timer relay, 3time functions, 4time ranges, for mounting on RIF-1, RIF-2, RIF-3, and RIF-4, input voltage: 12VDC...24VDC
Product Code: 2902647
Partner cod.: 2902647
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Plug-in module
Product family: RIFLINEcomplete
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics: Air clearances and creepage distances in a circuit
Insulation: Basic insulation
Overvoltage category: I
Pollution degree: 2
Electrical propertiesSetting accuracy: 3 % (of scale end value)
Nominal voltage UN: 24 V AC/DC
Repeat accuracy: 1 %
Air clearances and creepage distances in a circuit
Rated insulation voltage: 50 VDC
Rated surge voltage: 0.4 kV
Input dataNominal input voltage UN: 24 VDC (AC operation only permitted for RIF-1)
Input voltage range in reference to UN: 0.4 ... 1.2
Mains frequency: 50 Hz
60 Hz
Status display: Yellow LED
Protective circuit: Varistor
Surge voltage protection: > 56 V
Output dataLimiting continuous current: ≤ 250 mA (Relay coil current)
Voltage drop at max. limiting continuous current: < 100 mV
DimensionsWidth: 13 mm
Height: 12 mm
Depth: 35 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 50°C (RIF-1, AC coil, 2 changeover contacts at 6 A)
-25°C ... 50°C (RIF-1, DC coil, 2 changeover contacts at 5 A)
-25°C ... 40°C (RIF-2, DC coil, 2 changeover contacts at 8 A)
-25°C ... 40°C (RIF-2, DC coil, 4 changeover contacts at 5 A)
-25°C ... 40°C (RIF-3, DC coil, 3 changeover contacts at 6.75 A)
-25°C ... 40°C (RIF-3, DC coil, 2 changeover contacts at 8 A)
-25°C ... 35°C (RIF-4, DC coil, 3 changeover contacts at 8A)
-25°C ... 25°C (RIF-4, DC coil, 3 N/O contacts at 8 A)
Ambient temperature (storage/transport): -25°C ... 85°C
ApprovalsUKCA
Certificate: UKCA-compliant
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
Standards and regulationsAir clearances and creepage distances in a circuit
Standards/regulations: IEC 60947-5-1
MountingAssembly instructions: Can be inserted into relay base
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27371692
ECLASS-12.0: 27371692
ECLASS-13.0: 27371692
ETIMETIM 9.0: EC002586
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01190.pdf

Approvals_01218.pdf

Data_sheet_03770.pdf

Manufacturer_declaration_03047.pdf

Manufacturer_declaration_04753.pdf

Manufacturer_declaration_15716.pdf

Package_slip_02200.pdf

Product_information_00033.pdf

Product_information_00568.pdf

Technical_drawing_39638.pdf