Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2905028
PHOENIX CONTACTNot available

MINI MCR-2-UNI-UI-2UI-PT - Signal duplicator

Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
Product Code: 2905028
Partner cod.: 2905028
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Signal duplicator
Product family: MINI Analog Pro
No. of channels: 2
Type: Signal conditioner
Configuration: DIP switches
Software
App
Insulation characteristics: GBStandard
Overvoltage category: II
Pollution degree: 2
System propertiesFunctionality
Configuration: DIP switches
Software
App
Electrical propertiesNo. of channels: 2
Electrical isolation: 4-way isolation
Step response (0–99%): 140 ms (15 Hz sample rate)
45 ms (60Hz sample rate)
25 ms (240Hz sample rate, can only be set via software)
Maximum temperature coefficient: 0.01 %/K
Maximum transmission error: 0.05 % (of final value)
Electrical isolation Input/output/power supply
Rated insulation voltage: 300 Vrms
Test voltage: 3 kV AC (50Hz, 60s)
Insulation: Reinforced insulation according to IEC/EN61010-1
Supply
Nominal supply voltage: 24 VDC
Supply voltage range: 9.6 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Typical current consumption: 55 mA (24VDC)
110 mA (12VDC)
Power consumption: 1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
Input dataSignal: Voltage/current
Number of inputs: 1
Configurable/programmable: Yes
Voltage input signal: 0 V ... 10 V (via DIP switch)
2 V ... 10 V (via DIP switch)
0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 12 V (can be set via software)
Max. voltage input signal: 12 V
Current input signal: 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
0 mA ... 10 mA (via DIP switch)
20 mA ... 0 mA (via DIP switch)
0 mA ... 24 mA (can be set via software)
Max. current input signal: 24 mA
Input resistance of voltage input: > 120 kΩ
Input resistance current input: ~ 50 Ω (+0.7V for test diode)
Output dataSignal: Voltage/current
Number of outputs: 2
Voltage output signal: 0 V ... 10 V (via DIP switch)
2 V ... 10 V (via DIP switch)
0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10.5 V (can be set via software)
Max. voltage output signal: ~ 12.3 V
Non-load voltage: ≤ 18.5 V
Current output signal: 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
0 mA ... 10 mA (via DIP switch)
20 mA ... 0 mA (via DIP switch)
0 mA ... 21 mA (can be set via software)
Max. current output signal: 24.6 mA
Short-circuit current: ≤ 25 mA
Load/output load voltage output: ≥ 10 kΩ
Load/output load current output: ≤ 600 Ω (per channel)
Ripple: < 20 mVPP (600Ω)
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12 (flexible)
Ex dataEx installation (EPL): Gc
Div.2
InterfacesData: IFS interface
Connection method: Micro USB type B
SignalingStatus display: Green LED (supply voltage)
Error indication: Red LED
DimensionsWidth: 6.2 mm
Height: 109.81 mm
Depth: 119.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (not assessed by UL)
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: BVS 19 ATEX E 083 X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: PxCIF21UKEX2905026X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx BVS 19.0072X
CCC/China-Ex
Identification: Ex nA IIC T4 Gc
Certificate: NEPSIGYJ20.1318X
UL, USA/Canada
Identification: UL508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Shipbuilding approval
Certificate: DNV GL TAA000021E Rev. 1
EACEx
Identification:  2Ex ec IIC T4 Gc
Certificate: BY/112 02.01 TP012 103.01 00081
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Typical deviation from the measuring range final value: 0.2 %
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Typical deviation from the measuring range final value: 0.1 %
Surge current load (surge)
Standards/regulations: EN61000-4-5
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Typical deviation from the measuring range final value: 2.8 %
Standards and regulationsElectrical isolation: 4-way isolation
GBStandard
Standards/regulations: GB3836.1
GB3836.8
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210120
ECLASS-12.0: 27210120
ECLASS-13.0: 27210120
ETIMETIM 9.0: EC002653
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00128.pdf

Approvals_00172.pdf

Approvals_00173.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01461.pdf

Approvals_01467.pdf

Approvals_01944.pdf

Data_sheet_03867.pdf

Manual_00026.pdf

Manufacturer_declaration_00935.pdf

Manufacturer_declaration_01816.pdf

Manufacturer_declaration_15989.pdf

Manufacturer_declaration_17788.pdf

Package_slip_01638.pdf

Product_information_00015.pdf

Product_information_00033.pdf

Product_information_00650.pdf

Technical_drawing_40061.pdf