Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2905249
PHOENIX CONTACTNot available

MINI MCR-2-TC-UI-PT - Thermocouple measuring transducer

Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, standard configuration
Product Code: 2905249
Partner cod.: 2905249
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Temperature transmitter
Product family: MINI Analog Pro
Type: Signal conditioner
Configuration: DIP switches
Software
App
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
Electrical propertiesElectrical isolation: 3-way isolation
Typical cold point errors: 2 K (2 K + (0,2 K * ΔT))
Protective circuit: Transient protection
Step response (0–99%): 300 ms
570 ms
Maximum temperature coefficient: ≤ 0.01 %/K
Transmission error thermocouples: 0.1%*600K / setmeasuring range; 0.1%>600K(C, E, J, K, N, T, L, U, M Gost, L Gost)
0.2 % * 600 K / set measuring range; 0.2 % > 600 K (B, R, S, A1, A2, A3)
0.2%* 600K / set measuring range; 0.2%> 600K (E, J, K, N, T, L, U, M Gost, L Gost); Highspeed Mode
0.4%* 600K / set measuring range; 0.4%> 600K (B, R, S, A1, A2, A3); Highspeed Mode
Electrical isolation Input/output/power supply
Rated insulation voltage: 300 Vrms
Test voltage: 3 kV AC (50Hz, 60s)
Insulation: Reinforced insulation according to IEC/EN61010-1
Supply
Supply voltage range: 9.6 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715)
Typical current consumption: 32.7 mA (24VDC)
66.8 mA (12VDC)
Power consumption: ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
Input dataSignal
Number of inputs: 1
Measurement
Number of inputs: 1
Configurable/programmable: Yes
Input voltage range: - 500 mV ... 500 mV (can be set via software)
Sensor types that can be used (TC): B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range: -250°C ... 2500°C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
≥ 50 K
Voltage measuring range: 3 mV
Sensor type:: 500°C ... 1820°C
-230°C ... 1000°C
-210°C ... 1200°C
-250°C ... 1372°C
-200°C ... 1300°C
-50°C ... 1768°C
-50°C ... 1768°C
-200°C ... 400°C
-200°C ... 900°C
-200°C ... 600°C
0°C ... 2500°C
0°C ... 1800°C
0°C ... 1800°C
-200°C ... 100°C
-200°C ... 800°C
Output dataSignal: Voltage/current
Number of outputs: 1
Configurable/programmable: Yes
Voltage output signal: 0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10 V (via DIP switch)
10 V ... 0 V (via DIP switch)
0 V ... 10.5 V (can be set via software)
Max. voltage output signal:  12.3 V
Non-load voltage: < 17.5 V
Current output signal: 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
20 mA ... 0 mA (via DIP switch)
20 mA ... 4 mA (via DIP switch)
0 mA ... 21 mA (can be set via software)
Max. current output signal: 24.6 mA
Short-circuit current: < 31.5 mA
Load/output load voltage output: ≥ 10 kΩ
Load/output load current output: ≤ 600 Ω (20mA)
Ripple: < 10 mVrms
< 10 mVrms (600Ω)
Resolution, outputs (voltage): 1 mV
Resolution, outputs (current): 2 µA
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12 (flexible)
Ex dataEx installation (EPL): Gc
Div.2
InterfacesData: IFS interface
Connection method: Micro USB type B
SignalingStatus display: Green LED (supply voltage)
Error indication: Red LED
DimensionsWidth: 6.2 mm
Height: 109.81 mm
Depth: 119.2 mm
Material specificationsFire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2
Housing material: PBT
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (not assessed by UL)
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 2000 m
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: BVS 20 ATEX E 024 X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: PxCIF21UKEX2902049X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx BVS 20.0017X
UL, USA/Canada
Identification: UL508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Shipbuilding approval
Certificate: DNV GL TAA00002UA
EACEx
Identification:  2Ex ec IIC T4 Gc
Certificate: BY/112 02.01 TP012 103.01 00079
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Note: When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Comments: Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Typical deviation from the measuring range final value: 0.06 %
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Typical deviation from the measuring range final value: 0.1 %
Surge current load (surge)
Standards/regulations: EN61000-4-5
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Typical deviation from the measuring range final value: 0.05 %
Standards and regulationsElectrical isolation: 3-way isolation
MountingMounting type: DIN rail mounting
Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail.
Mounting position: any
Technical Specs
ECLASSECLASS-11.0: 27210129
ECLASS-12.0: 27210129
ECLASS-13.0: 27210129
ETIMETIM 9.0: EC002919
UNSPSCUNSPSC 21.0: 41112100
Description
Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, standard configuration
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00128.pdf

Approvals_00172.pdf

Approvals_00173.pdf

Approvals_01457.pdf

Approvals_01460.pdf

Approvals_01500.pdf

Data_sheet_03763.pdf

Manual_00026.pdf

Manufacturer_declaration_00750.pdf

Manufacturer_declaration_01935.pdf

Manufacturer_declaration_16021.pdf

Manufacturer_declaration_17788.pdf

Manufacturer_declaration_17795.pdf

Package_slip_01629.pdf

Product_information_00033.pdf

Product_information_00563.pdf

Technical_drawing_40100.pdf