Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Product type: Repeater power supplies Product family: MINI Analog Pro No. of channels: 2 Type: Signal conditioner Configuration: DIP switches Insulation characteristics: GBStandard Overvoltage category: II Pollution degree: 2 |
Electrical properties | No. of channels: 2 Electrical isolation: 4-way isolation Limit frequency (3 dB): > 1 kHz Signal transmission behavior: In=Out Step response (10-90%): < 400 µs Maximum temperature coefficient: 0.0075 %/K Maximum transmission error: 0.05 % (of final value) Electrical isolation Input/output/power supply Rated insulation voltage: 300 Vrms Test voltage: 3 kV AC (50Hz, 60s) Insulation: Reinforced insulation according to IEC/EN61010-1 Supply Nominal supply voltage: 24 VDC Supply voltage range: 9.6 VDC ... 30 VDC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN60715) Typical current consumption: 40 mA (For 24VDC and in signal duplicator mode) 65 mA (For 24 V DC and in power supply duplicator mode) 75 mA (For 12 V DC and in signal duplicator mode) 130 mA (For 12 V DC and in power supply duplicator mode) Power consumption: 1.6 W (at IOUT = 20 mA, 500 é load) |
Input data | Signal: Current Description of the input: Sensor circuit Number of inputs: 1 Current input signal: 0 mA ... 20 mA (Signal duplicator mode) 4 mA ... 20 mA (Power supply and signal duplicator mode) Input resistance current input: 90 é (+1.6V) Transmitter supply voltage: > 19.5 V |
Output data | Signal: Current Number of outputs: 2 Non-load voltage: < 20 V Current output signal: 0 mA ... 20 mA (Signal duplicator mode) 4 mA ... 20 mA (Power supply and signal duplicator mode) Max. current output signal: 25 mA Load/output load current output: ⤠500 é (per channel) Ripple: < 20 mVPP (500 é) |
Connection data | Connection method: Push-in connection Stripping length: 10 mm Conductor cross section rigid: 0.2 mm² ... 2.5 mm² (with ferrule) 0.14 mm² ... 2.5 mm² (without ferrule) Conductor cross section flexible: 0.14 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 (flexible) |
Ex data | Ex installation (EPL): Gc Div.2 |
Interfaces | Data communication (bypass) HART function: Yes Limit frequency (3 dB): ï» 1 kHz |
Signaling | Status display: Green LED (supply voltage) |
Dimensions | Width: 6.2 mm Height: 109.81 mm Depth: 119.2 mm |
Material specifications | Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2 Housing material: PBT |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (not assessed by UL) Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠2000 m Permissible humidity (operation): 5 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant ATEX Identification: ï II 3 G Ex ec ic IIC T4 Gc Certificate: BVS 19 ATEX E 047 X UKCAEx(UKEX) Identification: ï II 3 G Ex ec ic IIC T4 Gc Certificate: PxCIF21UKEX2902000X IECEx Identification: Ex ec ic IIC T4 Gc Certificate: IECEx BVS 19.0041X CCC/China-Ex Identification: Ex nA ic IIC T4 Gc UL, USA/Canada Identification: UL508 Listed Class I, Div. 2, Groups A, B, C, D T5 Class I, Zone 2, Group IIC T5 Shipbuilding approval Certificate: DNV GL TAA000021E Rev. 1 EACEx Identification: ï 2Ex ec ic IIC T4 Gc Certificate: BY/112 02.01 TP012 103.01 00081 DNV GL data Temperature: B Humidity: B Vibration: A EMC: A Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Noise immunity: EN 61000-6-2 Note: When being exposed to interference, there may be minimal deviations. Electromagnetic compatibility: Conformance with EMC directive Noise emission: EN 61000-6-4 Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Comments: Safety measures must be taken to prevent electrostatic discharge. Electromagnetic HF field Designation: Electromagnetic RF field Standards/regulations: EN61000-4-3 Fast transients (burst) Designation: Fast transients (burst) Standards/regulations: EN61000-4-4 Surge current load (surge) Standards/regulations: EN61000-4-5 Conducted interference Designation: Conducted interferences Standards/regulations: EN61000-4-6 |
Standards and regulations | Electrical isolation: 4-way isolation GBStandard Standards/regulations: GB3836.1 GB3836.4 GB3836.8 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35mm EN60715 DIN rail. Mounting position: any |
ECLASS | ECLASS-11.0: 27210120 ECLASS-12.0: 27210120 ECLASS-13.0: 27210120 |
ETIM | ETIM 9.0: EC002653 |
UNSPSC | UNSPSC 21.0: 39121000 |
Description other products