PHOENIX CONTACT 2907877
PHOENIX CONTACTNot available

VAL-SEC-T2-48DC-P - Type 2 surge protection plug

Replacement plug for surge protective devices from the VALVETRAB SEC product range for DC power sources.
Product Code: 2907877
Partner cod.: 2907877
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesIEC test classification: II
T2
EN type: T2
IEC power supply system: DC
Type: Male
Product type: Replacement plug
Product family: SEC Family
Number of positions: 1
Surge protection fault message: optical
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNominal voltage UN: 48 VDC ... 60 VDC
Connection dataConnection method: pluggable
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/e7cb446bdeab77498a0d023a1cee84c2/-S204x204-FJPG
Width: 11.7 mm
Height: 46.4 mm
Depth: 59.4 mm
Horizontal pitch: 0.6 Div.
Material specificationsFlammability rating according to UL 94: V-0
CTI value of material: 600
Insulating material: PA6.6-FR 20% GF
PBT-FR
Material group: I
Housing material: PA 6.6-FR 20% GF
PBT-FR
Protective circuitMode of protection: (DC+) - (DC-)
(DC+) - PE
(DC-) - PE
Direction of action: (DC+/DC-) - PE
Nominal voltage UN: 60VAC (TN)
48 VDC ... 60 VDC
Maximum continuous voltage UC: 75 VDC
75 VAC
Residual current IPE: ≤ 50 µA DC
Nominal discharge current In (8/20) µs: 20 kA
Maximum discharge current Imax (8/20) µs: 40 kA
Impulse discharge current (10/350)µs, charge: 2 As
Impulse discharge current (10/350)µs, specific energy: 4 kJ/Ω
Impulse discharge current (10/350)µs, peak value limp: 4 kA
Short-circuit current rating ISCCR: 0.2 kA DC (without backup fuse)
6 kA DC (for 20 A gG/B backup fuse)
10 kA AC (C63A miniature circuit breaker)
25 kA AC (for a backup fuse of up to 315AgG)
50 kA AC (for a backup fuse of up to 200AgG)
Voltage protection level Up: ≤ 0.5 kV
Residual voltage Ures: ≤ 0.5 kV (at In)
≤ 0.4 kV (at 10 kA)
≤ 0.35 kV (at 5 kA)
≤ 0.3 kV (at 2 kA)
TOV behavior at UT: 87 VDC (5s / withstand mode)
100 VAC (5s / withstand mode)
Response time tA: ≤ 25 ns
Max. backup fuse with V-type through wiring: 20 ADC (gG / B at ISCCR > 200 A)
Max. backup fuse with branch wiring: 20 ADC (gG / B at ISCCR > 200 A)
315 A AC
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 80°C
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 6000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
ApprovalsUL specifications
Maximum continuous operating voltage MCOV: 75 VDC
Short-circuit current rating (SCCR): 50 kA
Voltage protection rating VPR: 400 V
Nominal discharge current In: 20 kA
Mode of protection: (DC+) - G
(DC-) - G
Nominal voltage: 48 VDC
Power distribution system: DC
SPD Type: 1CA
Standards and regulationsStandards/specifications: IEC 61643-11
Note: 2011
EN 61643-11
Standards/specifications: EN61643-11
Note: 2012
MountingMounting type: on base element
Technical Specs
ECLASSECLASS-11.0: 27130890
ECLASS-13.0: 27171292
ETIMETIM 9.0: EC002496
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00200.pdf

Approvals_01875.pdf

Flyer_00001.pdf

Flyer_00002.pdf

Flyer_00003.pdf

Manufacturer_declaration_00922.pdf

Manufacturer_declaration_02053.pdf

Package_slip_00572.pdf

Technical_drawing_40536.pdf