Industrial Automation
UM-2KS50/32IM/SI/BFI/YCS - Passive module
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | Product type: Interface module Operating mode: 100% operating factor Insulation characteristics Insulation: Functional insulation Insulation characteristicsâ Insulation: Functional insulation Overvoltage category: II Pollution degree: 2 |
Electrical properties | Nominal voltage UN: 24 VDC 19.2 VDC ... 26.4 VDC Max. current carrying capacity per branch: 250 mA (observe derating) Max. total current of all branches: 2 A (observe derating) Rated insulation voltage: 50 VDC Rated surge voltage: 0.5 kV Supported controller YOKOGAWA CENTUM VP Suitable I/O card: ADV151 ADV161 NFDV151 NFDV161 |
Output data | Contact switching type: 1 N/O contact Type of switch contact: Double contact Contact material: AgNi, 5 µm hard gold-plated Maximum switching voltage: < 25 VAC 48 VDC Limiting continuous current: 1 A Min. switching current: 1 mA Interrupting rating (ohmic load) max.: 24 W (24VDC) 48 W (48VDC) 25 VA (25VAC) Mechanical service life: approx. 2x 107 cycles |
Connection data | Field level Connection method: Screw connection Stripping length: 5 mm Screw thread: M2 Number of connections: 32 Number of positions: 2 Conductor cross section rigid: 0.14 mm² ... 1.5 mm² Conductor cross section flexible: 0.14 mm² ... 1 mm² (without ferrule) Conductor cross section AWG: 26 ... 16 Tightening torque: 0.22 Nm ... 0.25 Nm Controller level Connection method: Yokogawa KS-compatible Number of connections: 2 Number of positions: 50 |
Signaling | Status display: LED red Status display present: Yes, if the fuse fails Operating voltage display: Green LED |
Dimensions | Item dimensions Width: 135 mm Height: 127.79 mm Depth: 61.82 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP00 Ambient temperature (operation): -20°C ... 50°C Ambient temperature (storage/transport): -20°C ... 80°C Altitude: ⤠2000 m Permissible humidity (operation): 10 % ... 95 % (non-condensing) |
Standards and regulations | Standards/regulations: DINEN50178 |
Mounting | Mounting type: DIN rail mounting Assembly instructions: in rows with zero spacing Mounting position: any |
Notes | General: Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. No additional touch protection is required when using a SELV/PELV voltage (⤠25VAC or 60VDC). Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e.g. partition plates). For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
ECLASS | ECLASS-11.0: 27141152 ECLASS-13.0: 27141152 ECLASS-12.0: 27141152 |
ETIM | ETIM 9.0: EC002780 |
UNSPSC | UNSPSC 21.0: 39121400 |
Description other products