Product properties | IEC test classification: II T2 EN type: T2 IEC power supply system: TN-S TT Type: DIN rail module, two-section, divisible Product type: Surge arrester Product family: SEC Family Number of positions: 2 Surge protection fault message: Optical, remote indicator contact Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal frequency fN: 50 Hz (60Hz) Indicator/remote signaling Connection name: Remote fault indicator contact Switching function: Changeover contact Operating voltage: 5 VAC ... 250 VAC 125 VDC (200 mA DC) Operating current: 5 mA AC ... 1 A AC 1 ADC (30VDC) |
Connection data | Connection method: Screw connection Fork-type cable lug Screw thread: M5 Tightening torque: 4.5 Nm Stripping length: 16 mm Conductor cross section flexible: 2.5 mm² ... 16 mm² 1.5 mm² ... 6 mm² Conductor cross section rigid: 2.5 mm² ... 25 mm² Conductor cross section AWG: 12 ... 4 Remote fault indicator contact Connection method: Plug-in/screw connection via COMBICON Screw thread: M2 Tightening torque: 0.25 Nm Stripping length: 7 mm Conductor cross section flexible: 0.14 mm² ... 1.5 mm² Conductor cross section rigid: 0.14 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/ca716f833cb13c4a9fc33a7788d5d52c/-S204x204-FJPG Width: 25.4 mm Height: 97.9 mm Depth: 74.5 mm (incl. DIN rail 7.5mm) Horizontal pitch: 1.4 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PA6.6-FR 20% GF PBT-FR Material group: I Housing material: PA 6.6-FR 20% GF PBT-FR |
Protective circuit | Mode of protection: L-N L-PE N-PE Direction of action: 1L-N & N-PE Nominal voltage UN: 240VAC (TN-S) 240VAC (TT) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous operating voltage UC (L-N): 350 VAC Maximum continuous operating voltage UC (L-PE): 350 VAC Maximum continuous operating voltage UC (N-PE): 264 VAC Rated load current IL: 40 A (Biconnect M4 fork-type cable lug 6â mm²) 63 A (TWIN ferrule 2 x 10 mm²) Residual current IPE: ⤠1 µA Nominal discharge current In (8/20) µs (L-N): 10 kA Nominal discharge current In (8/20) µs (L-PE): 10 kA Nominal discharge current In (8/20) µs (N-PE): 20 kA Maximum discharge current Imax (8/20) µs (L-N): 20 kA Maximum discharge current Imax (8/20) µs (L-PE): 20 kA Maximum discharge current Imax (8/20) µs (N-PE): 40 kA Follow current interrupt rating Ifi (N-PE): 100 A (264 V AC) Short-circuit current rating ISCCR: 50 kA Voltage protection level Up (L-N): ⤠1.5 kV Voltage protection level Up (L-PE): ⤠2.3 kV Voltage protection level Up (N-PE): ⤠1.5 kV Residual voltage Ures (L-N): ⤠1.35 kV (at In) ⤠1.1 kV (at 5 kA) ⤠0.95 kV (at 2 kA) ⤠0.9 kV (at 1 kA) Residual voltage Ures (L-PE): ⤠1.75 kV (at In) ⤠1.2 kV (at 5 kA) ⤠1.05 kV (at 2 kA) ⤠0.95 kV (at 1 kA) Residual voltage Ures (N-PE): ⤠0.5 kV (at In) ⤠0.5 kV (at 10 kA) ⤠0.5 kV (at 5 kA) ⤠0.5 kV (at 4 kA) ⤠0.5 kV (at 2 kA) TOV behavior at UT (L-N): 457 VAC (5s / withstand mode) 457 VAC (120min / withstand mode) TOV behavior at UT (N-PE): 1200 VAC (200ms / withstand mode) Response time tA: ⤠100 ns Max. backup fuse with V-type through wiring: 40 A (gG / Biconnect M4 fork-type cable lug, 6â mm²) 63 A (gG / TWIN ferrule 2x 10mm²) Max. backup fuse with branch wiring: 200 A (gG) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 80°C Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % |
Standards and regulations | Standards/specifications: IEC 61643-11 Note: 2011 EN 61643-11 Standards/specifications: EN61643-11 Note: 2012 |
Mounting | Mounting type: DIN rail: 35 mm |
ECLASS | ECLASS-11.0: 27130805 ECLASS-13.0: 27171202 |
ETIM | ETIM 9.0: EC000941 |
UNSPSC | UNSPSC 21.0: 39121600 |