PHOENIX CONTACT 2924304
PHOENIX CONTACTNot available

MACX MCR-SL-2NAM-R-UP-SP - Isolation amplifier

2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
Product Code: 2924304
Partner cod.: 2924304
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Isolating switch transf.
Product family: MACX Analog
No. of channels: 2
Type: Signal conditioners with SIL functional safety
Configuration: DIP switches
System propertiesFunctionality
Configuration: DIP switches
Electrical propertiesNo. of channels: 2
Electrical isolation: 3-way isolation
Electrical isolation between input and output: yes
Maximum power dissipation for nominal condition: ≤ 1.3 W
Step response (10-90%): typ. 6 ms (N/O contact: OFF/ON)
typ. 6 ms (N/O contact: ON/OFF)
typ. 4 ms (N/C contact: ON/OFF)
typ. 10 ms (N/C contact: OFF/ON)
Electrical isolation​
Test voltage: 2.5 kV AC (50Hz, 60s)
Electrical isolation Input/output IEC/EN60079-11
Standards/regulations: IEC/EN60079-11
Rated insulation voltage: 375 VPP
Overvoltage category: III
Pollution degree: 2
Electrical isolation Input/power supply IEC/EN60079-11
Standards/regulations: IEC/EN60079-11
Rated insulation voltage: 375 VPP
Overvoltage category: II
Pollution degree: 2
Electrical isolation Input/power supply IEC/EN61010-1
Standards/regulations: IEC/EN61010-1
Rated insulation voltage: 300 Vrms
Overvoltage category: II
Pollution degree: 2
Insulation: Safe isolation
Electrical isolation Output 1/output 2/input, power supply IEC/EN61010-1
Standards/regulations: IEC/EN61010-1
Rated insulation voltage: 300 Vrms
Overvoltage category: III
Pollution degree: 2
Insulation: Safe isolation
Supply
Nominal supply voltage range: 24 V AC/DC ... 230 V AC/DC -20%...+10% (50/60Hz)
Supply voltage range: 19.2 V AC/DC ... 253 V AC/DC (50/60Hz)
Max. current consumption: < 80 mA
< 42 mA (24VDC)
Power dissipation: < 1.1 W
Power consumption: < 1.1 W
Input dataSignal: NAMUR
Number of inputs: 2
Available input sources: NAMUR proximity sensors (IEC/EN60947-5-6)
Floating switch contacts
Switch contacts with resistance circuit
Switching threshold "0" signal current: < 1.2 mA (blocking)
Switching threshold "1" signal, current: > 2.1 mA (conductive)
Short-circuit current: 8 mA
Switching hysteresis: < 0.2 mA
Line fault detection: < 0.05 mA ... 0.35 mA (Line break)
< 100 Ω ... 360 Ω (Short circuit)
Activated /deactivated via DIP switch
Non-load voltage: 8 VDC
Output dataSwitching: Relay
Contact switching type: 1changeover contact per channel
Contact material: AgSnO2, hard gold-plated
Maximum switching voltage: 250 VAC (2 A, 60 Hz)
120 VDC (0.2A)
30 VDC (2A)
Maximum switching capacity: 500 VA
Recommended minimum load: 5 V / 10 mA
Switching frequency: ≤ 20 Hz (Load-dependent)
Signal
Number of outputs: 2
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible (2 conductors with same cross section): 0.25 mm² ... 0.34 mm² (TWIN ferrule without plastic sleeve)
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG: 24 ... 14
24 ... 22 (TWIN ferrule without plastic sleeve)
20 ... 16 (TWIN ferrule with plastic sleeve)
Ex dataEx installation (EPL): Gc
Div.2
InterfacesData
No. of channels: 0
SignalingStatus display: Green LED (supply voltage)
LED yellow (switching state)
Red LED (line errors)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/1c258931fba07944af0146676a5cf2c7/-S204x204-FJPG
Width: 17.5 mm
Height: 107.9 mm
Depth: 113.7 mm
Depth NS35/7,5: 114.5 mm (Snapped onto DIN rail NS35/7,5 in accordance with EN60715)
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Housing material: PA 6.6-FR
CharacteristicsSafety data
Safety Integrity Level (SIL): 2
Safety data​
Safety Integrity Level (SIL): 2
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -40°C ... 60°C (Any mounting position)
-40°C ... 70°C (Derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Altitude range (≤ 2000 m)
Altitude: ≤ 2000 m (The technical data refers to altitudes ≤2000m above mean sea level. For altitudes >2000m above mean sea level, refer to the data sheet.)
Ambient temperature (operation): -40°C ... 60°C
-40°C ... 70°C (Derating)
Rated insulation voltage: 253 VAC (Power supply, input / output)
125 VDC (Power supply, input / output)
Altitude range (≤ 3000 m)
Height range: > 2000 m ... 3000 m
Ambient temperature (operation): -40°C ... 54°C
-40°C ... 63°C (Derating)
Rated insulation voltage: 190 VAC (Power supply, input / output)
110 VDC (Power supply, input / output)
Altitude range (≤ 4000 m)
Height range: > 3000 m ... 4000 m
Ambient temperature (operation): -40°C ... 48°C
-40°C ... 56°C (Derating)
Rated insulation voltage: 60 V AC/DC (Power supply, input / output)
Altitude range (≤ 5000 m)
Height range: > 4000 m ... 5000 m
Ambient temperature (operation): -40°C ... 42°C
-40°C ... 49°C (Derating)
Rated insulation voltage: 60 V AC/DC (Power supply, input / output)
ApprovalsCE
Certificate: CE-compliant
Note: and EN61326-1
ATEX
Identification:  II 3G Ex ec nC IIC T4 Gc
Certificate: IBExU 20 ATEX B011 X
UKCAEx(UKEX)
Identification:  II 3 G Ex nA nC IIC T4 Gc X
Certificate: PxCIF21UKEX2865052X
IECEx
Identification: Ex ec nC IIC T4 Gc
Certificate: IBE 10.0002 X
CCC/China-Ex
Identification: Ex ec nC IIC T4 Gc
Certificate: 2021122304114199
UL, USA/Canada
Identification: UL508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
Certificate: DNV GL TAA000020C
Safety Integrity Level (SIL, IEC 61508)
Identification: 2
INMETRO
Identification: Ex ec nC IIC T4 Gc
Certificate: DNV 18.0116 X
EACEx
Identification:  2Ex ec nC IIC T4 Gc
Certificate: BY/112 02.01 TP012 103.01 00078
DNV GL data
Temperature: B
Humidity: B
Vibration: A
EMC: A
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataNoise immunity: EN 61000-6-2
Electromagnetic compatibility: Conformance with EMC directive
Noise emission: EN 61000-6-4
Electromagnetic HF field
Designation: Electromagnetic RF field
Standards/regulations: EN61000-4-3
Evaluation criterion: A
Fast transients (burst)
Designation: Fast transients (burst)
Standards/regulations: EN61000-4-4
Evaluation criterion: A
Conducted interference
Designation: Conducted interferences
Standards/regulations: EN61000-4-6
Evaluation criterion: A
Standards and regulationsElectrical isolation: 3-way isolation
GBStandard
Standards/regulations: GB/T3836.1
GB/T3836.3
GB/T3836.8
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27210121
ECLASS-12.0: 27210121
ECLASS-13.0: 27210121
ETIMETIM 9.0: EC001485
UNSPSCUNSPSC 21.0: 39121000
Description
2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output, for each channel there is a relay with a changeover contact available. Line fault detection (LFD), 3-way isolation, Push-in connection, SIL 2.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00369.pdf

Approvals_01164.pdf

Approvals_01505.pdf

Approvals_01530.pdf

Data_sheet_03588.pdf

Manual_00026.pdf

Manufacturer_declaration_00630.pdf

Manufacturer_declaration_01996.pdf

Manufacturer_declaration_16589.pdf

Manufacturer_declaration_17787.pdf

Package_slip_01557.pdf

Technical_drawing_41120.pdf