Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

PHOENIX CONTACT 2963734
PHOENIX CONTACTNot available

PSR-SCP- 24UC/URM4/5X1/2X2 - Extension module

1-channel or 2-channel contact extension, 5N/O contacts, 1N/C contact, 1confirmation current path, together with basic device up to Cat.4 PLe in accordance with ENISO13849 safe isolation, width: 35mm, pluggable screw terminal block
Product Code: 2963734
Partner cod.: 2963734
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Extension module
Mechanical service life: approx. 107 cycles
Relay type: Safety relay for contact extension
Times
Typ. starting time with Us: < 20 ms (at Us / when controlled via A11/A12)
Typical release time: < 20 ms (at Us / when controlled via A11/A12)
Recovery time: < 1 s
Electrical propertiesMaximum power dissipation for nominal condition: 15.8 W (US=26.4V, IL²=72A², PTotalmax=1.4W+14.4W)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 V
Rated surge voltage/insulation: See section “Insulation coordination”
Input dataGeneral
Rated control circuit supply voltage US: 24 V -20%...+10%
Power consumption at US: 1 W (with DC)
1.2 W (with AC)
Rated control supply current IS: typ. 39 mA (per channel, DC)
typ. 50 mA (per channel, AC)
Inrush current: typ. 200 mA (Δt=2ms at Us, per channel)
Protective circuit: Surge protection; Varistor (40V breakdown voltage)
Output dataContact switching type: 5 enabling current paths
1 confirmation current path
1 signaling current path
Contact material: AgSnO2
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 5 V AC/DC
Limiting continuous current: 6 A (N/O contact)
3 A (N/C contact 11/12)
6 A (N/C contact 71/72)
Maximum inrush current: 6 A
Inrush current, minimum: 10 mA
Sq. Total current: 72 A2 (ITH2 = I12 + I22 + ... + I52)
Switching capacity min.: 50 mW
Switching capacity in accordance with IEC 60947-5-1: 3 A (AC15)
5 A (DC13)
Output fuse: 10 A gL/gG (N/O contact)
6 A gL/gG (N/C contact)
Relay
Interrupting rating (ohmic load) max.: see load limit curve
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque: 0.5 Nm ... 0.6 Nm
SignalingOperating voltage display: 2x green LED
DimensionsWidth: 35 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 4 (In conjunction with suitable evaluating device)
Performance level (PL): e (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: EN60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: Observe derating
Mounting position: vertical or horizontal
Connection method: Screw connection
Technical Specs
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Description
Single-channel or two-channel contact extension, 5 N/O contacts, 1 N/C contact, 1 confirmation current path, together with basic device up to Cat. 4 PL e in accordance with EN ISO 13849 safe isolation, width: 35 mm, pluggable screw terminal block
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Data_sheet_03956.pdf

Manufacturer_declaration_00785.pdf

Manufacturer_declaration_02128.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_16837.pdf

Package_slip_01914.pdf

Technical_drawing_41431.pdf