PHOENIX CONTACT 2976187
PHOENIX CONTACT 2976187
PHOENIX CONTACTNot available

UMK- 8 RELS/KSR-G24/21-21/PLC - Active module

VARIOFACE output module, with plug-in bases for 8 miniature relays, with 2 changeover contacts each (without relays), for 24 V DC
Product Code: 2976187
Partner cod.: 2976187
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
Product propertiesProduct type: Interface module
No. of channels: 8
Operating mode: 100% operating factor
Mechanical service life: 3x 107 cycles
Compatible components: Miniature relay, REL-MR- 24DC/21-21
With components: no
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesNo. of channels: 8
Rated insulation voltage: 300 VAC
Rated surge voltage: 4 kV (Basic insulation between output contact current paths)
6 kV (Safe isolation and reinforced insulation between input circuit and output contact paths)
Supported controller SIEMENS S7-1500
Suitable I/O card: 6ES7522-1BH00-0AB0
6ES7522-1BH01-0AB0
6ES7522-1BL00-0AB0
6ES7522-1BL01-0AB0
Supported controller SIEMENS S7-300 / ET 200 M
Suitable I/O card: CPU 313C-2DP
CPU 314C-2DP
CPU 314C-2PtP
6ES7322-1BH01-0AA0
6ES7322-1BL00-0AA0
6ES7323-1BH01-0AA0
6ES7323-1BL00-0AA0
CPU 313C
CPU 313C-2PtP
Supported controller SIEMENS S7-400
Suitable I/O card: 6ES7422-1BL00-0AA0
6ES7422-7BL00-0AB0
Supported controller ALLEN-BRADLEY PLC 5
Suitable I/O card: 1771 OBN
Supported controller ALLEN-BRADLEY SLC 500
Suitable I/O card: 1746 OB 32
Supported controller ABB S800 I/O
Suitable I/O card: DO810
DO840
Supported controller GE-FANUC RX3i
Suitable I/O card: IC694MDL754
Supported controller HONEYWELL Experion PKS C200
Suitable I/O card: TC-ODD 321
Supported controller MITSUBISHI MELSEC L
Suitable I/O card: LY41PT1P
LY42PT1P
Supported controller MITSUBISHI MELSEC Q
Suitable I/O card: QY81P
QY82P
Input dataNominal input voltage UN: 24 VDC
Protective circuit: Freewheeling diode; Freewheeling diode
Operating voltage display: Green LED
Status display/channel: Yellow LED
Output dataCompatible components: Miniature relay, REL-MR- 24DC/21-21
Switching
Note: The interrupting ratings apply when using the REL-MR- 24DC/21-21 relay (2961192)
Contact switching type: 2 changeover contacts
Maximum switching voltage: 250 V AC/DC
Limiting continuous current: 3 A
Min. switching current: 10 mA
Interrupting rating (ohmic load) max.: 72 W (at 24 V DC)
96 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
57 W (at 220 V DC)
750 VA (for 250 V AC)
Error detection (line break / short-circuit): no
Connection dataController level
Connection method: IDC/FLK pin strip
Number of connections: 1
Number of positions: 14
Pitch: 2.54 mm
Field level
Connection method: Screw connection
Stripping length: 6 mm
Screw thread: M3
Number of connections: 48
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 26 ... 14
Supply
Connection method: Screw connection
Stripping length: 6 mm
Screw thread: M3
Number of connections: 2
Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
Conductor cross section AWG: 26 ... 14
SignalingStatus display present: Yes
DimensionsWidth: 135 mm
Height: 77 mm
Depth: 54 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP00
Ambient temperature (operation): -20°C ... 50°C
Ambient temperature (storage/transport): -20°C ... 70°C
Standards and regulationsStandards/regulations: EN61010-2-201
IEC 60664
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
NotesGeneral: Observe the maximum switching capacity of the relays used
Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
The outputs are not suitable for switching different line conductors. The sum of the switching voltages used for adjacent outputs must not exceed the rated insulation voltage value
The necessary requirements for insulation (basic insulation or reinforced insulation) from adjacent modules (in DIN-rail direction) must be realized by applying suitable measures (e.g., partition plates).
For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.
Utilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Technical Specs
ECLASSECLASS-11.0: 27141152
ECLASS-12.0: 27141152
ECLASS-13.0: 27141152
ETIMETIM 9.0: EC002780
UNSPSCUNSPSC 21.0: 39121400
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00005.pdf

Manufacturer_declaration_00653.pdf

Manufacturer_declaration_01998.pdf

Manufacturer_declaration_16979.pdf

Product_information_00033.pdf

Product_information_00189.pdf

Technical_drawing_41608.pdf