Industrial Automation
PT 4-L/HESI (5X20) - Fuse modular terminal block


Notes | General: The current is determined by the fuse used, the voltage by the selected LED. If the fuse is faulty, the downstream circuit will not be disconnected. |
Product properties | Product type: Fuse terminal block Number of connections: 4 Number of rows: 3 Potentials: 2 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Electrical properties | Fuse type: Glass / ceramics / ... Rated surge voltage: 6 kV Maximum power dissipation for nominal condition: 1.02 W Fuse: G / 5 x 20 Maximum power dissipation: max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload) max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit) max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) |
Connection data | Number of connections per level: 2 Nominal cross section: 4 mm² Level 1 Stripping length: 10 mm ... 12 mm Internal cylindrical gage: A4 Connection in acc. with standard: IEC 60947-7-3 Conductor cross section rigid: 0.2 mm² ... 6 mm² Cross section AWG: 24 ... 10 (converted acc. to IEC) Conductor cross section flexible: 0.2 mm² ... 6 mm² Conductor cross section, flexible [AWG]: 24 ... 10 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.25 mm² ... 4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.25 mm² ... 4 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 1 mm² Nominal current: 28 A Maximum load current: 32 A (with 6Ãmm² conductor cross section, rigid) Nominal voltage: 500 V Nominal cross section: 4 mm² Level 2 Stripping length: 10 mm ... 12 mm Connection in acc. with standard: IEC 60947-7-3 Conductor cross section rigid: 0.2 mm² ... 6 mm² Cross section AWG: 24 ... 10 (converted acc. to IEC) Conductor cross section flexible: 0.2 mm² ... 6 mm² Conductor cross section, flexible [AWG]: 24 ... 10 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.25 mm² ... 4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.25 mm² ... 4 mm² Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve): 0.5 mm² ... 1 mm² Nominal current: 6.3 A Maximum load current: 6.3 A (the current is determined by the fuse used) Nominal voltage: 500 V (the voltage is determined by the fuse used) Nominal cross section: 4 mm² Level 1 Connection cross sections directly pluggable Conductor cross section rigid: 0.5 mm² ... 6 mm² Conductor cross section, rigid [AWG]: 20 ... 10 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 4 mm² Level 2 Connection cross sections directly pluggable Conductor cross section rigid: 0.5 mm² ... 6 mm² Conductor cross section, rigid [AWG]: 20 ... 10 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.5 mm² ... 4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 4 mm² |
Ex data | Rated data (ATEX/IECEx) Identification: ïà IIÃ3ÃGÃÃEx ec llC Gc Operating temperature range: -60°C ... 130°C Ex-certified accessories: 3002619 D-PT 4-PE/L/HESI 1205066 SZS 1,0X4,0 VDE 3022276 CLIPFIX 35-5 3022218 CLIPFIX 35 List of bridges: Plug-in bridgeÃ/ÃFBS 2-6Ã/Ã3030336 Plug-in bridgeÃ/ÃFBS 3-6Ã/Ã3030242 Plug-in bridgeÃ/ÃFBS 4-6Ã/Ã3030255 Plug-in bridgeÃ/ÃFBS 5-6Ã/Ã3030349 Plug-in bridgeÃ/ÃFBS 10-6Ã/Ã3030271 Plug-in bridgeÃ/ÃFBS 20-6Ã/Ã3030365 Bridge data: 19 AÃ/Ã4 mm² Rated voltage: 275 V for bridging with bridge: 275 V - At bridging between non-adjacent terminal blocks: 275 V - At cut-to-length bridging with cover: 275 V Rated insulation voltage: 250 V output: (Permanent) Ex connection data General Nominal cross section: 4 mm² Rated cross section AWG: 12 Connection capacity rigid: 0.2 mm² ... 6 mm² Connection capacity AWG: 24 ... 10 24 ... 12 Connection capacity flexible: 0.2 mm² ... 4 mm² output: (Permanent) Ex level Level 2 Rated current: 29 A (4Ãmm²) Maximum load current: 32 A (6 mm²) Contact resistance: 0.9 mé Temperature increase: 40 K (29 A / 4 mm²) output: (Permanent) Ex level Level 3 Rated current: 6.3 A (4Ãmm²) Maximum load current: 6.3 A (6 mm²) Contact resistance: 5 mé |
Dimensions | Width: 6.2 mm Height: 118.5 mm Depth: 82.6 mm Depth on NSÃ35/7,5: 83.9 mm Depth on NSÃ35/15: 91.4 mm |
Material specifications | Color: black Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60°C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)): 130°C Relative insulation material temperature index (Elec., UL 746 B): 130°C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Calorimetric heat release NFPA 130 (ASTM E 1354): 28 MJ/kg Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed |
Mechanical properties | Mechanical data Open side panel: Yes |
Environmental and real-life conditions | Oscillation/broadband noise Specification: DINÃENÃ50155 (VDEÃ0115-200):2008-03 Spectrum: Service life test categoryÃ1, classÃB, body mounted Frequency: f1 = 5 Hz to f2 = 150 Hz ASD level: 0.964 (m/s²)²/Hz Acceleration: 0.58g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DINÃENÃ50155 (VDEÃ0115-200):2008-03 Pulse shape: Half-sine Acceleration: 5g Shock duration: 30Ãms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (operation): -60°C ... 105°C (max. short-term operating temperature RTI Elec.) Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24Ãh, -60ðC to +70ðC) Ambient temperature (assembly): -5°C ... 70°C Ambient temperature (actuation): -5°C ... 70°C Permissible humidity (storage/transport): 30 % ... 70 % |
Standards and regulations | Connection in acc. with standard: IEC 60947-7-3 |
Mounting | Mounting type: NS 35/7,5 NSÃ35/15 |