Industrial Automation
Notes | General Note: The current is determined by the fuse used, the voltage by the fuse or selected light indicator. |
Product properties | Product type: Fuse terminal block Number of connections: 2 Number of rows: 1 Potentials: 1 Insulation characteristics Overvoltage category: III Degree of pollution: 3 |
Electrical properties | Fuse type: Flat Rated surge voltage: 6 kV Maximum power dissipation for nominal condition: 1.02 W Fuse: C Maximum current with single arrangement: 30 A |
Connection data | Number of connections per level: 2 Nominal cross section: 4 mm² 1 level Stripping length: 8 mm ... 10 mm Internal cylindrical gage: A4 Connection in acc. with standard: IEC 60947-7-3 Conductor cross section rigid: 0.08 mm² ... 6 mm² Cross section AWG: 28 ... 10 (converted acc. to IEC) Conductor cross section flexible: 0.08 mm² ... 4 mm² Conductor cross section, flexible [AWG]: 28 ... 12 (converted acc. to IEC) Conductor cross-section flexible (ferrule without plastic sleeve): 0.14 mm² ... 4 mm² Flexible conductor cross section (ferrule with plastic sleeve): 0.14 mm² ... 4 mm² 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve: 0.5 mm² ... 1 mm² Nominal current: 30 A Maximum load current: 30 A Nominal voltage: 400 V Nominal cross section: 4 mm² |
Dimensions | Width: 8.2 mm Height: 86.5 mm Depth on NS35/7,5: 43.5 mm Depth on NS35/15: 51 mm |
Material specifications | Color: black Flammability rating according to UL 94: V0 Insulating material group: I Insulating material: PA Static insulating material application in cold: -60°C Relative insulation material temperature index (Elec., UL 746 B): 130°C Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3 Surface flammability NFPA 130 (ASTM E 162): passed Specific optical density of smoke NFPA 130 (ASTM E 662): passed Smoke gas toxicity NFPA 130 (SMP 800C): passed |
Mechanical properties | Mechanical data Open side panel: No |
Environmental and real-life conditions | Oscillation/broadband noise Specification: DINEN50155 (VDE0115-200):2022-06 Spectrum: Service life test category1, classB, body mounted Frequency: f1 = 5 Hz to f2 = 150 Hz ASD level: 0.964 (m/s²)²/Hz Acceleration: 0.58g Test duration per axis: 5 h Test directions: X-, Y- and Z-axis Result: Test passed Shocks Specification: DINEN50155 (VDE0115-200):2022-06 Pulse shape: Half-sine Acceleration: 5g Shock duration: 30ms Number of shocks per direction: 3 Test directions: X-, Y- and Z-axis (pos. and neg.) Result: Test passed Ambient conditions Ambient temperature (operation): -60°C ... 110°C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C) Ambient temperature (assembly): -5°C ... 70°C Ambient temperature (actuation): -5°C ... 70°C Permissible humidity (operation): 20 % ... 90 % Permissible humidity (storage/transport): 30 % ... 70 % |
Standards and regulations | Connection in acc. with standard: IEC 60947-7-3 |
Mounting | Mounting type: NS 35/7,5 NS35/15 |