Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

ROCKWELL AUTOMATION 140M-C2N-A25
ROCKWELL AUTOMATION 140M-C2N-A25
ROCKWELL AUTOMATION 140M-C2N-A25
ROCKWELL AUTOMATION 140M-C2N-A25
ROCKWELL AUTOMATIONNot available

Motor Circuit Protector Circuit-Breaker

MCP, Standard Magnetic Trip (Fixed at 13 x le), 0.25 A, Std. Performance, Frame Size C
Product Code: 140M-C2N-A25
Partner cod.: 140M-C2N-A25
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
Number of poles3
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100 kA
Complete device with protection unitYes
Rated permanent current Iu0.25 A
Rated voltage230 V
Type of control elementTurn button
Rated frequency60 Hz
Magnetic release current per IEC3.3 A
Rated operational current (Ie) per IEC0.25 A
Rated supply current (Ie)0.1 A
Ultimate short circuit breaking capacity (Icu) per IEC100 kA @ 690V
Rated service short circuit breaking capacity (Ics) per IEC100 kA @ 690V
Magnetic trip current3.3 A
Rated insulation voltage (Ui)690V per IEC, SEV, VDE0660
KW rating, max0.09 kW @ 690V (AC-3), 3-phase
Switching of standard motors per IEC0.09 kW @ 690V (AC-3), 3-phase
Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IECNo back-up fuse required @ 690V
Short circuit current (Type 2 coordination), max65 kA @ 480V
Short circuit current for group motor installation with 100-C contactor, max65 kA @ 480V, UL 508—manual motor controller
Short circuit current for motor disconnect with 100-C contactor, max65 kA @ 480V, UL 508—manual motor controller
Electrical life cycle100000 operations (Ie maximum)
Rated thermal current (Ith)0.1...32 A @ 60 °C ambient temperature
Fuse or circuit breaker per NEC, max450 A, UL 508—manual motor controller with 100-C contactor
Rated impulse withstand voltage (Uimp)Main circuits/overvoltage category: 6 kV/III
Short circuit current for group motor installation, max65 kA @ 480V, UL 508—manual motor controller
Short circuit current for motor disconnect, max65 kA @ 480V, UL 508—manual motor controller
Short circuit current for self-protected combination motor controller with 100-C contactor, max65 kA @ 480Y/277V, UL-508—Type E self-protected combination motor controller
Magnetic release current (±20 %)Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges
Protection typeFixed magnetic only (13 x In)
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalYes
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Switching frequency, max25 ops/h
Total power loss (Pv) for circuit breaker at rated load operating temperature6 W
Ultimate interrupting current for group motor65 kA @ 480V
Phase loss protectionDifferential release
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP2X
Weight315 lb
Mechanical life operations100000 /h
Breaking capacityStandard breaking capacity
Factory optionNo circuit-breaker auxiliary or trip contacts
Vibration resistanceOperation (60068-2-6): 5 G
Shock resistanceTransport (60068-2-27): 30 G, 11 ms, all axes
Ambient storage temperature-40 °C
Ambient operating temperature-25 °C
Ambient temperature compensation-20 °C
Site altitudeto 2000 m N.N. (6561 ft)
Dependence on temperatureNo reduction @ 60 °C (140 °F)
Pollution degree3
Moisture heat (60068-2-3)40 °C, relative humidity 93 %, 56 days
Dry heat (60086-2-2)100 °C, relative humidity < 50 %, 7 days
Moisture change climate (600068-2-30)23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles
Frame sizeFrame size C, 32 A
Contactor size (Type 2 coordination), min100-C09 @ 600V
Contactor size, min100-C09, UL-508—Type E self-protected combination motor controller
Device constructionBuilt-in device fixed built-in technique
Utilization categoryMotor starter: AC-3 (IEC60947-4-1)