ROCKWELL AUTOMATION 20DD8P0A0EYYAEANE
ROCKWELL AUTOMATION 20DD8P0A0EYYAEANE
ROCKWELL AUTOMATION 20DD8P0A0EYYAEANE
ROCKWELL AUTOMATIONNot available

PowerFlex 700S AC Drive 8 A 5 Hp 20D

PowerFlex700S AC Drive, 480 VAC, 3 PH, 8 Amps, 5HP Normal Duty, 3HP Heavy Duty, IP20 / Type 1, with conformal coating, No HIM (Blank Plate), Brake IGBT Installed, Drive Mounted Brake Resistor Installed, Second Environment Filter per CE EMC directive (89/336/EEC), Ethernet/IP - DPI Module, Phase II control, Expanded cassette, Standard (Incremental Encoder), Phase II, No DriveLogix, no embedded comm
Product Code: 20DD8P0A0EYYAEANE
Partner cod.: 20DD8P0A0EYYAEANE
ROCKWELL AUTOMATION


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Degree of protection (IP)IP20
Shock10 G peak for 11 ms duration (±1.0 ms)
PWM frequency4 kHz @ 650V DC
Vibration0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz
Number of analogue outputs2
Mains voltage480 V
Integrated breaking resistanceYes
Max. output voltage932 V
Internal dynamic brake resistors115 Ohm
DC bus overvoltage trip810V DC @ 480V
DC nominal bus voltage648V DC @ 480V
Brake IGBTBrake IGBT installed
Internal communication moduleEtherNet/IP
Fuse current rating15 A @ 650V DC
Input voltage rating480V AC, 3-phase, 60 Hz
Displacement power factor0.98 across speed range
Output current, continuous8.0 A @ 650V DC
Output current, 1 min8.8 A @ 650V DC
Output current, 3 sec12 A @ 650V DC
Circuit breaker current rating, max30 A @ 480V AC, 3-phase
Motor circuit protector current rating, max15 A @ 480V AC, 3-phase
Logic control ride-thru0.25 seconds, drive not running
Brake resistorWith internal brake resistor
Input current rating8.1 A @ 650V DC
Rated power rating5 Hp @ 650V DC, normal duty
DocumentationEnglish documentation
Carrier frequencyDrive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz operation only)
AC input overvoltage trip600V AC @ 480V (six pulse, 3-phase)
Input power rating5.7 kVA @ 480V AC, 3-phase
Electronic motor overload protectionClass 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Dual element time delay fuse current rating10...15 A @ 480V AC, 3-phase
Non-time delay fuse current rating10...30 A @ 480V AC, 3-phase
Heat sink thermistorMonitored by microprocessor overtemperature trip
Drive to motor power ratio, maxThe drive to motor rating cannot exceed a 2:1 ratio
Stop modesMultiple programmable stop modes including – Ramp, Coast, and Current Limit
Acceleration/decelerationIndependently programmable accel and decel times adjustable from 0 to 6553.5 in 0.1 second increments
Number of digital inputs6
Number of digital outputs2
Number of analogue inputs3
Motor voltage, nom460V @ 380...400V drive rating, 480V nominal line voltage
Human interface modelNo HIM (no blank plastic inserted)
Additional configurationPhase II control
Max. output frequency400 Hz
Line voltage, nom480V @ 380...400V drive rating, 460V nominal motor voltage
Mains frequency60 Hz
Internal EMC filteringWith EMC filter & common mode choke
Watt loss210 W @ 480V AC, 5 Hp normal duty, 3 Hp heavy duty
Feedback optionFuture use
Drive full power range460...528V @ 380...400V drive rating, 460V nominal motor voltage
Drive operating range325...528V @ 380...400V drive rating, 460V nominal motor voltage
Torque regulationTorque regulation - without feedback: ±5%, 600 rad/sec bandwidth
Enclosure typeIP20/NEMA/UL Type 1
Output current rating8 amps, 5 Hp normal duty, 3 Hp heavy duty, frame 1
Control optionsPhase II control, expanded cassette
Drive overcurrent tripSoftware current limit: 105% of motor rated to 200% of drive rated current
Efficiency97.5% at rated amps, nominal line volts
Speed controlSpeed regulation - without feedback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Current limit capabilityIndependent motoring and regenerative power limits programmable to 800% of rated output current
Selectable motor controlField oriented control with and without a feedback device and permanent magnet motor control
Input phasesSix-pulse, 3-phase input provides full rating for all drives, single-phase operation provides 50% of rated current
Control methodInduction motor and brushless motor: sine coded PWM with programmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
Number of phases output3
Number of phases input3
Relative symmetric net voltage tolerance10 %
Input frequency, max400 Hz
Output frequency range0 Hz
DC bus undervoltage tripAdjustable
Output voltage range0 to rated motor voltage
Power ride-thru15 milliseconds at full load
S-curve timeAdjustable 0.5...4.0 seconds
Short circuit tripPhase-to-phase on drive output
Ground fault tripPhase-to-ground on drive output
Control logic noise immunityShowering arc transients upto 1500V peak
Line transientsUp to 6000 volts peak per IEEE C62.41-1991
Intermittent overload110% overload capability for up to 1 minute, 150% overload capability for up to 3 seconds
Short circuit current, maxUsing recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ≤200000 Amps
Encoder voltage supply5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC, 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC
Height, approx336 mm
Depth, approx200 mm
Width, approx166.9 mm
Weight, approxDrive: 7.03 kg
Sound levelFrame 1: 59 dB @ 30 CFM fan speed
Altitude1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)1
AtmosphereDrive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors, or dust, If the drive is not going to be installed for a period of time, it must be stored in an area where it will not be exposed to a corrosi
Operating temperature50 °C @ 650V DC
Storage temperature-40 °C
Relative humidity5...95% noncondensing
Surrounding air temperature without deratingNEMA/UL Type 1: 0° to 40° C (32° to 104° F)
Technical Specs
Base Drive Information
Input Voltage:480 VAC, 3 PH
Output Current:8 Amps
Enclosure:IP20 / Type 1, with conformal coating
Frame Size:Frame Size 1
Brake IGBT:Brake IGBT Installed
Brake Resistor:Drive Mounted Brake Resistor Installed
EMC Filtering Options:Second Environment Filter per CE EMC directive (89/336/EEC)
Phase II, Control Options:Phase II control, Expanded cassette
Feedback Option:Standard (Incremental Encoder)
Additional Configurations:Phase II, No DriveLogix, no embedded comm
Firmware:Standard
Options
Base Plus Options:Factory Assembled
Human Interface Module:No HIM (Blank Plate)
Internal Communication Module:Ethernet/IP - DPI Module