Features | Applications | Evaluation unit | Compatible sensor types | Safety sensors with OSSDs |
|
Safety-related parameters | Safety integrity level | SIL 3 (IEC 61508) | Category | Category 4 (ISO 13849-1) | Performance level | PL e (ISO 13849-1) | PFHD (mean probability of a dangerous failure per hour) | 1.0 x 10-9 | TM (mission time) | 20 years (ISO 13849-1) | Stop category | 0 (IEC 60204-1) |
|
Functions | Sensor monitoring | Sequence monitoring | Restart interlock | ✔ | Reset | Automatic Manual | External device monitoring (EDM) | ✔ |
|
Interfaces | Connection type | Front connector with spring terminals | Inputs | 2 safety inputs 1 input for reset pushbutton or external device monitoring (EDM) | Outputs | 2 enabling current paths (safe) 2 application diagnostic outputs (not safe) 1 test pulse output (not safe) | Display elements | LEDs | Configuration method | Hard wired |
|
Electrical data - Operating data | Voltage supply | PELV or SELV | Supply voltage VS | 24 V DC (16.8 V ... 30 V) | Residual ripple | ≤ 2.4 V | Power consumption | ≤ 2.5 W (DC) |
|
Electrical data - Safety inputs | Number | 2 | Input voltage | | HIGH | 24 V DC (11 V ... 30 V) | LOW | 0 V DC (–3 V ... 5 V) |
| Input current | 4 mA ... 6 mA | Test pulse width | ≤ 1 ms | Test pulse rate | ≤ 10 Hz |
|
Electrical data - Reset pushbutton or external device monitoring (EDM) input | Number | 1 | Input voltage | | HIGH | 24 V DC (11 V ... 30 V) | LOW | 0 V DC (–3 V ... 5 V) |
| Input current | 4 mA ... 6 mA |
|
Electrical data - Enabling current paths | Response time | 10 ms | Number | 2 | Type of output | N/O contacts, positively guided | Contact material | Silver alloy, gold flashed | Switching voltage | 10 V AC ... 230 V AC 10 V DC ... 230 V DC | Switching current | 10 mA ... 6 A | Total current | 12 A | Mechanical life | 1 x 107 switching cycles | Overvoltage category | III (EN 60664-1) | Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
|
Electrical data - Application diagnostic outputs | Number | 2 | Type of output | Push-pull semiconductor output, short-circuit protected | Output voltage | | HIGH | ≥ Vs – 3 V | LOW | ≤ 3 V |
| Input current (NPN) | ≤ 15 mA | Output current (PNP) | ≤ 120 mA |
|
Electrical data - Test pulse outputs | Number | 1 | Type of output | PNP semiconductors, short-circuit protected | Output voltage | ≥ Vs – 3 V | Test pulse width | 2 ms | Test pulse interval | 40 ms |
|
Mechanical data | Dimensions (W x H x D) | 18 mm x 124.6 mm x 85.5 mm | Weight | 130 g |
|
Ambient data | Enclosure rating | IP20 (IEC 60529) | Ambient operating temperature | –25 °C ... +55 °C | Storage temperature | –25 °C ... +70 °C | Air humidity | ≤ 95 %, Non-condensing | Interference emission | According to IEC 61000-6-4 | Interference resistance | According to IEC 61326-3-1 According to IEC 61000-6-2 According to IEC 60947-5-1 |
|
Classifications | eCl@ss 5.0 | 27371990 | eCl@ss 5.1.4 | 27371990 | eCl@ss 6.0 | 27371819 | eCl@ss 6.2 | 27371819 | eCl@ss 7.0 | 27371819 | eCl@ss 8.0 | 27371819 | eCl@ss 8.1 | 27371819 | eCl@ss 9.0 | 27371819 | eCl@ss 10.0 | 27371819 | eCl@ss 11.0 | 27371819 | eCl@ss 12.0 | 27371819 | ETIM 5.0 | EC001449 | ETIM 6.0 | EC001449 | ETIM 7.0 | EC001449 | ETIM 8.0 | EC001449 | UNSPSC 16.0901 | 41113704 |
|