Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

SICK 1090867
SICKNot available

CFP0200-XPBNNCT

Level sensors: CFP Cubic
Product Code: 1090867
Partner cod.: 1090867
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Features
MediumFluids
MeasurementSwitch, Continuous
Probe length200 mm
Process pressure–0.5 bar ... 3 bar
Process temperature–20 °C ... +80 °C
UL approval
RoHS certificate
IO-Link
Performance
Accuracy of sensor element± 15 mm, with water or oil under reference conditions
Reproducibility< 5 mm
Resolution< 2 mm
Response time< 300 ms
Dielectricity constant≥ 2
ConductivityNo limitation
Deactivated area at end of probe7 mm ... 15 mm, Depending on probe length
MTTF171 years
Display
Temperature measurement
Measuring range (temperature)–20 °C ... +80 °C
Measurement accuracy (temperature)± 2 °C
Resolution (Temperature)≤ 0.1 °C
Response time (temperature)120 s
Electronics
Supply voltage10 V DC ... 30 V DC 
Power consumption≤ 100 mA at 24 V DC without output load
Initialization time≤ 4 s
Protection classIII
Connection typeM12 round connector x 1, 8-pin
Output signal4 x PNP/NPN/push-pull transistor outputs switchable and 2 x analog outputs 4 mA ... 20 mA, 0 V ... 10 V depending on output load or output voltage depending on the load
Output load4 mA ... 20 mA < 500 Ohm at Uv > 15 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 0 V ... 10 V > 750 Ohm at Uv 14 ≥ V
HysteresisMin. 3 mm, min. 2 °C, free adjustable
Output current< 100 mA
Inductive load< 1 H
Capacitive load100 nF
Enclosure ratingIP67
Temperature drift< 0.1 mm/K
Lower signal level3.8 mA ... 4 mA
Upper signal level20 mA ... 20.5 mA
Resolution of analog output12 bit
Mechanics
Wetted parts

Outer tube: polypropylene (PP-H)

G ¾” and ¾” NPT: PPSU

Easy-clamp bracket: PP

Process connection¾" NPT
Housing materialPBT / PC
Max. probe load≤ 4 Nm
Probe diameter16 mm
Ambient data
Ambient operating temperature–20 °C ... +60 °C
Ambient temperature, storage–40 °C ... +80 °C
Classifications
ECLASS 5.027200503
ECLASS 5.1.427200503
ECLASS 6.027200503
ECLASS 6.227200503
ECLASS 7.027200503
ECLASS 8.027200503
ECLASS 8.127200503
ECLASS 9.027200503
ECLASS 10.027200503
ECLASS 11.027200503
ECLASS 12.027200503
ETIM 5.0EC001447
ETIM 6.0EC001447
ETIM 7.0EC001447
ETIM 8.0EC001447
UNSPSC 16.090141113710
Technical Specs
Unit weight0.445 Kilograms
Net unit weight0.445 Kilograms
Unit volume4032 Cubic Centimetres (cm³)
Measurements8.000*12.000*42.000
Country of originGermany
EAN4047084417887