SICK 1099701
SICKNot available

TTK70S-HXJ0-K02

Linear encoders: TTK70
Product Code: 1099701
Partner cod.: 1099701
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Features
Items suppliedMagnetic tape not included with delivery
Safety-related parameters
Safety integrity levelSIL 2 (IEC 61508), SILCL2 (EN 62061) 
Category3 (EN ISO 13849)
Maximum demand rateContinuous (analog signals)
Performance levelPL d (EN ISO 13849)
PFHD: Probability of dangerous failure per hour2.02 x 10-8 
TM (mission time)20 years (EN ISO 13849)
Safety-related accuracy± 25 mm, = ± 1/4 pin length
Safety-related measuring step0.25 mm
Performance
Measuring step0.244 µm For interpolation of the sine/cosine signals with, e. g., 12 bits
Measuring range0 mm ... 3,920 mm
Resolution1 µm
Length of period1 mm
Traversing speed≤ 10 m/s, 1.3 m/s up to which the absolute position can be reliably produced
Repeatability< 5 µm
System accuracy± 10 µm (+20 °C)
Measured value backlash< 10 µm
Interfaces
Communication interfaceHIPERFACE® 
Code typeBinary
Available memory area1,792 Byte (E2PROM 2048)
Electrical data
Supply voltage7 V DC ... 12 V DC
Recommended supply voltage8 V DC
Operating current≤ 65 mA (without load) 
Connection typeCable, 8-wire (4 x 2 x 0.15 mm²), 0.5 m
Mechanical data
DimensionsSee dimensional drawing
Scope of deliveryMagnetic tape not included with delivery
Weight0.08 kg
Read head materialZinc diecast
Ambient data
EMCAccording to EN 61000-6-2 and EN 61000-6-3 
Enclosure ratingIP67, with mating connector inserted (IEC 60529)
Operating temperature range–30 °C ... +80 °C
Storage temperature range–40 °C ... +85 °C, without package
Permissible relative humidity100 %, condensation permitted
Resistance to shocks30 g, 6 ms (EN 60068-2-27)
Resistance to vibration20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
Maximum permitted ambient field strength< 3 kA/m ... 4 kA/m (3.8 mT ... 5 mT), to guarantee compliance with the quoted accuracy values 
Maximum permitted field strength< 150 kA/m (< 190 mT), to ensure that the magnetic tape is not permanently damaged
Classifications
eCl@ss 5.027270705
eCl@ss 5.1.427270705
eCl@ss 6.027270705
eCl@ss 6.227270705
eCl@ss 7.027270705
eCl@ss 8.027270705
eCl@ss 8.127270705
eCl@ss 9.027270705
eCl@ss 10.027270705
eCl@ss 11.027270705
eCl@ss 12.027274304
ETIM 5.0EC002544
ETIM 6.0EC002544
ETIM 7.0EC002544
ETIM 8.0EC002544
UNSPSC 16.090141111613
Technical Specs
Unit weight0.271 Kilograms
Net unit weight0.271 Kilograms
Unit volume2754 Cubic Centimetres (cm³)
Measurements18.000*8.500*18.000
Country of originGermany