Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

SICK 1114233
SICKNot available

FTS-H100F04B

Flow sensors: T-Easic FTS
Product Code: 1114233
Partner cod.: 1114233
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Features
Measurement principleCalorimetric measurement process
MediumWater and oil-based liquids
Pipe diameters≥ 25 mm 
Measuring range
3 cm/s ... 300 cm/s, Water
3 cm/s ... 300 cm/s, Oil A / Oil B
3 cm/s ... 600 cm/s, Taught-in media 
Process temperature–40 °C ... +150 °C 
Process pressure–1 bar ... 100 bar, 40 bar (with SICK T-connector DN15, DN25), 25 bar (with SICK T-connector DN40), 20 bar (with SICK T-connector DN50) 
Communication interfaceIO-Link, IO-Link V1.1, COM3 (230.4 kbit/s)
Temperature measurement
Performance
Inlet zone5 x DN
Output zone3 x DN
Measurement accuracy
± 7 % From measured value + 2% of measuring range end value 
Repeatability< 1 cm/s 
Resolution0.01 m/s Speed; 0.1 L/min volume; 0.1% relative (via IO-Link)
Temperature drift< 0.5 cm / (s*K) 
Response time< 2.5 s 
Temperature measurement
Measurement accuracy (temperature)± 1 °C
Resolution (Temperature)< 0.1 °C
Response time (temperature)< 5 s 
Operating modeRelative speed (%), Volume flow and total volume, Relative teach (%)
Electronics
Supply voltage9 V DC ... 30 V DC 
Power consumption

< 2 W at 24 V DC (without load on the outputs)

< 8 W At maximum load

Initialization time

≤ 5 s

≤ 10 s (IO-Link)

Protection classIII
Connection typeM12 round connector x 1, 4-pin
Output signal2 push-pull digital outputs (Q1 configurable for IO-Link; Q2 configurable as analog output (4 … 20 mA) / pulse output / digital input) for flow and temperature
Output current< 100 mA 
Output load4 mA ... 20 mA, max. 350 Ohm, if Uv < 12 V, 500 Ohm if Uv> 12 V
Lower signal level3.5 mA ... 3.8 mA
Upper signal level20.5 mA ... 21.5 mA
InaccuracyQA Pin2: < 0.5% full-range (20 mA)
Inductive load1 H
Capacitive load100 nF (2.5 nF, IO-Link mode)
EMCEN 61326-1, EN 61326-2-3
Digital input limit

HIGH voltage dependent on Uv

LOW voltage < 4.0 V

MTTF> 200 years
Mechanics
Process connectionWithout process connection (adapter needed for installation)
Wetted partsStainless steel 1.4404 (Ra ≤ 0,8 µm)
Housing materialStainless steel 1.4404 / 316L
Enclosure ratingIP67 / IP69 
Probe diameter8 mm
Probe length100 mm
Minimum immersion length12 mm
Distance to pipe wall10 mm
Ambient data
Ambient operating temperature–40 °C ... +70 °C 
Ambient temperature, storage–40 °C ... +80 °C
Classifications
ECLASS 5.027273101
ECLASS 5.1.427273101
ECLASS 6.027273101
ECLASS 6.227273101
ECLASS 7.027273101
ECLASS 8.027273101
ECLASS 8.127273101
ECLASS 9.027273101
ECLASS 10.027273101
ECLASS 11.027273101
ETIM 5.0EC002580
ETIM 6.0EC002580
ETIM 7.0EC002580
ETIM 8.0EC002580
UNSPSC 16.090141112501
Technical Specs
Unit weight0.386 Kilograms
Net unit weight0.386 Kilograms
Unit volume4032 Cubic Centimetres (cm³)
Measurements12.000*8.000*42.000
Country of originGermany
EAN4047084514500