SICK 5308066
SICKNot available

LL3-TY01 LIGHT GUIDE

Fiber-optic sensors and fibers: LL3
Product Code: 5308066
Partner cod.: 5308066
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Features
Device typeFibers
Functional principleThrough-beam system
Functional principle detailConsisting of a sender and a receiver
For fiber-optic sensorGLL170(T), WLL180, WLL24 Ex, WLL80
Fiber length2,000 mm
Fiber materialPolymethylmethacrylat (PMMA)
Jacket materialPolytetrafluorethylen (PTFE)
Fiber head materialPolytetrafluorethylen (PTFE)
Outer diameter, fiber-optic cable connection2.2 mm
Fiber-optic cable cuttable
Smooth sleeve diameter (greatest diameter)6 mm
Fiber-optic head designSmooth sleeve
Fiber arrangementMonofiber
Core structureØ 1,0 mm Monofiber
Angle of dispersion < 60°Yes
Compatibility with infrared light (1,450 nm)No
ApplicationResistant to oil/chemicals
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion34.45°
Integrated lensYes
Minimal object diameter0.3 mm 
Included with deliveryFC fiber cutter (5304141)
Compatibility tip adaptersNo
Special featuresTeflon sheathing: chemically resistant
Mechanics/electronics
Bend radius, fibre-optic cable60 mm
Ambient operating temperature–40 °C ... +70 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs620 mm
Operating mode 70 µs1,760 mm
Operating mode 250 µs2,905 mm
Operating mode 500 µs3,500 mm
Operating mode 1 ms3,600 mm
Operating mode 2 ms3,600 mm
Operating mode 8 ms3,600 mm
Sensing ranges with WLL180T
Operating mode 16 µs400 mm
Operating mode 70 µs1,200 mm
Operating mode 250 µs2,100 mm
Operating mode 2 ms4,000 mm
Operating mode 8 ms4,000 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs870 mm
Sensing ranges with GLL170T
Operating mode 50 µs800 mm
Operating mode 250 µs1,370 mm
Technical Specs
Unit weight0.105 Kilograms
Net unit weight0.105 Kilograms
Unit volume1000 Cubic Centimetres (cm³)
Measurements20.000*2.500*20.000
Country of originJapan
EAN4047084152191