Industrial Automation
O.R. PMXX-ST® PLUS
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Formation: | (7G2,50)ST |
installation type: | CABLE FOR DYNAMIC INSTALLATION ON DRAG CHAIN |
category: | MULTI CORE |
standard/approval: | CE/UL/CSA |
shielding: | SHIELDED |
group // Power conductors / 7G2,50 | conductor material: Bare copper capillary diameter: - Extra-flexible (DIN VDE 0295, IEC 60228 or CEI 20-29) conductors number: 7 rated section: 2,50 mm² insulation material: Polyolefin colour: Black conductors with numbers from 1 to 6 + Green/Yellow. |
total assembly make-up | intermediate taping on make-up: Around the total assembly. material: Non-woven tape total shield on make-up: On the tape. material: Tinned copper shield shape: Braid shield coverage: >=85 % drain wire: Not available total taping on make-up: On the shield. material: Non-woven tape total sheath material: Polyurethane non-abrasive colour: Gray RAL 7001 diameter (mm): 13.5±0.4 Marking Metric marking: P/N ***** TE.CO. E244280 - Fxx - cRUus - AWM STYLE 21209 90°C 1000V VW-1 - AWM I/II A/B 90°C 1000V FT1 - (nxXAWG) - O.R. PMXX-ST® (nGY)SH - IEC 60332-1-2 - year/week - CE meter indication electrical features working voltage: 1000 V test voltage: 4000 V insulation resistance: >100 Mohm/Km acc. EN 50395 prt.8 (90°C) additional note: BRAIDING RESISTANCE additional note text: 250 Ohm/Km (at 30 MHz) dynamic features minimum bending radius static installation: 4 times ø cable minimum bending radius dynamic installation: 6 times ø cable working temperature static installation: -40°C / +90°C working temperature dynamic installation: -30°C / +90°C travel speed: Up to 300 m/min acceleration/deceleration: Up to 50 m/sec² cable length inside chain: Up to 20 m chain length notes: (horizontal only) guaranteed cycles: Up to 5 Mio torsions: +/- 30°/m notes: The given data are meant to be restricted to the type of reference installation. For fixed installation is meant to be without any mechanica stress. For application in dynamic installation with very low temperatures, contact our technical department. approvals and standards reference standards: 1581, UL 758(UL); C22.2 n° 210(CSA); Referring to DIN VDE 0207,0285,0819 and 0295. ul csa approvals: RU E244280 AWM STYLE 21209 90°C 1000V CSA E244280 AWM I/II A/B 90°C 1000V fire behaviour: VW-1(UL); FT1(CSA); IEC 60332-1-2(EU); DIN VDE 0482-332-1-2; DIN EN 60 332-1-2; UL CABLE FLAME HALOGEN FREE: IEC 60754-1(EU); EN 50267-1(EU) industrial oil resistance: 1581(UL); IEC 60811-404(EU); CEI EN 50363-10-2(EU); VDE 0473-811-404 halogen free: SI UV resistance: ASTM ASTM-D-2565-16; EN 50289-4-17(EU); ISO 4892-2 Customs code Customs-tariff number: 85444999 Made in: IT |
Description other products