Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1088132
PHOENIX CONTACT 1088132
PHOENIX CONTACTDisponibile

AXL SE IOL4 - Communication module

Axioline SmartElements, IO-Link master, IO-Link ports Class A: 4, connection method: Push-in connection, connection technology: 3-conductor, degree of protection: IP20
Cod. Articolo: 1088132
Cod. Fornitore: 1088132
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
InterfacesSmartElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartElement.
Start time until ready to operate: < 500 ms
System propertiesModule
ID code (hex): none
Process data channel: 512 bit
Input address area: 64 Byte
Output address area: 64 Byte
Input dataDigital
Description of the input: IO-Link ports in digital input (DI) mode
Number of inputs: max. 4 (EN 61131-2 type 1)
Connection method: Push-in connection
Connection technology: 3-conductor
Nominal input voltage UIN: 24 VDC
Input voltage range "0" signal: -0.3 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Nominal input current: typ. 2.5 mA
Sensor current per channel: max. 500 mA (from L+/L-)
Input filter time: 1 µs
IO-Link
Number of ports: 4
Connection method: Push-in connection
Connection technology: 3-conductor
Port type: Class A
Output dataDigital
Output description: IO-Link ports in digital output (DO) mode
Connection method: Push-in connection
Connection technology: 2-, 3-conductor
Number of outputs: max. 4
Nominal output voltage: 24 VDC
Nominal current per channel: 200 mA
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartElements
Mounting position: See the system in which the SmartElement is used.
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesSupply: IO-Link
Nominal voltage for I/O supply: 24 VDC
Supply voltage range: 18 VDC ... 30 VDC (including all tolerances, including ripple)
Nominal current for every IO-Link port: 500 mA (at L+/L-)
200 mA (at C/Q)
Protective circuit: Overload protection for L+; electronically limited to 0.6A
Short-circuit protection for L+; by switching off after 55ms
Potentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VDC (using card edge connectors)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 2030 mA (Internal current consumption + full load of the 4 IO-Link ports (4 x 500mA))
typ. 2020 mA
Current consumption: min. 18 mA (without connected peripherals)
Power consumption: max. 61 W (of which 1.45W internal losses)
min. 432 mW
Protective circuit: Surge protection; See the system in which the SmartElement is used.
Reverse polarity protection; Polarity protection diode
Electrical isolation/isolation of the voltage ranges
Test voltage: Communications supply / 24 V supply (I/O): 500 VAC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: Smart Element slot
Mounting position: See the system in which the SmartElement is used.
Specifiche
ECLASSECLASS-11.0: 27242608
ECLASS-12.0: 27242608
ECLASS-13.0: 27242608
ETIMETIM 9.0: EC001604
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00139.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Data_sheet_00561.pdf

Manual_00006.pdf

Manual_00045.pdf

Manual_00007.pdf

Manufacturer_declaration_01281.pdf

Manufacturer_declaration_02463.pdf

Manufacturer_declaration_04371.pdf

Manufacturer_declaration_06300.pdf

Quick_start_guide_00004.pdf

Technical_drawing_08045.pdf