STEP3-PS/1AC/24DC/5/PT - Power supply unit

Primary-switched power supply unit, STEPPOWER, Push-in connection, DIN rail or direct mounting, input:1-phase, output: 24 VDC / 5 A, adjustable from 22 VDC ... 27 VDC
Cod. Articolo: 1088478
Cod. Fornitore: 1088478
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
Input dataAC operation
Supply system configuration: Star network (TN, TT, IT (PE))
Input voltage range: 100 VAC ... 240 VAC -15%...+10%
Derating: < 115 VAC ... 85 VAC (1%/V)
Typical national grid voltage: 120 VAC
230 VAC
Voltage type of supply voltage: AC/DC
Inrush current: typ. 37 A
Inrush current integral (I2t): typ. 0.4 A2s
Frequency range (fN): 50 Hz ... 60 Hz ±10%
Mains buffering time: typ. 20 ms (120VAC)
typ. 20 ms (230VAC)
Current consumption: 1.32 A (100VAC)
0.57 A (240VAC)
Protective circuit: Transient surge protection; Varistor
Switch-on time: typ. 2 s
Device mains fuse: 4 A internal (device protection), slow-blow
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE: < 0.25 mA
DC operation
Input voltage range: 110 VDC ... 250 VDC -10%...+40%
Derating: < 115 VDC ... 99 VDC (1%/V)
Current consumption: 1.29 A (110VDC)
0.51 A (250VDC)
Output dataEfficiency: > 93 % (120VAC)
> 94.5 % (230VAC)
Efficiency Level: VI
Nominal output voltage: 24 VDC
Setting range of the output voltage (USet): 22 VDC ... 27 VDC (> 24 VDC, constant capacity restricted)
Nominal output current (IN): 5 A
Short-circuit-proof: yes
No-load proof: yes
Derating: > 50°C ... 70°C (2%/K)
Crest factor: typ. 1.74 (120VAC)
typ. 2.08 (230 VAC)
Output power (PN): 120 W
Connection in parallel: yes, for increasing power and redundancy with diode
Connection in series: yes, for increased output voltage
Feedback voltage resistance: ≤ 35 VDC
Protection against overvoltage at the output (OVP): < 35 VDC
Residual ripple: typ. 150 mVPP
Control deviation: < 0.5 % (Static load change 10% ... 90%)
< 3 % (Dynamic load change 10% ... 90%, (10 Hz))
< 0.1 % (change in input voltage ±10 %)
Rise time: typ. 100 ms (UOut=10%...90%)
Minimum no-load power dissipation: < 0.21 W (120VAC)
Maximum no-load power dissipation: < 0.21 W (230 V AC)
Minimum nominal load power dissipation: < 8.8 W (120VAC)
Power loss nominal load max.: < 6.8 W (230 V AC)
Connection dataInput
Position: 1.x
Connection technology
Position marking: 1.1, 1.2(L), 1.3, 1.4(N)
Conductor connection
Connection method: Push-in connection
rigid: 0.2 mm² ... 2.5 mm²
1 mm² (recommended)
flexible: 0.2 mm² ... 2.5 mm²
1 mm² (recommended)
flexible with ferrule without plastic sleeve: 0.5 mm² ... 1.5 mm²
1 mm² (recommended)
flexible with ferrule with plastic sleeve: 0.2 mm² ... 1 mm²
1 mm² (recommended)
rigid (AWG): 24 ... 14 (Cu)
17 (recommended)
Stripping length: 10 mm (rigid/flexible)
10 mm (Ferrule)
Output
Position: 2.x
Connection technology​
Position marking: 2.1, 2.2, 2.3, 2.4 (+), 2.5, 2.6, 2.7, 2.8(-)
Conductor connection​
Connection method: Push-in connection
rigid: 0.2 mm² ... 2.5 mm²
1 mm² (recommended)
flexible: 0.2 mm² ... 2.5 mm²
1 mm² (recommended)
flexible with ferrule without plastic sleeve: 0.5 mm² ... 1.5 mm²
1 mm² (recommended)
flexible with ferrule with plastic sleeve: 0.2 mm² ... 1 mm²
1 mm² (recommended)
rigid (AWG): 24 ... 14 (Cu)
17 (recommended)
Stripping length: 10 mm (rigid/flexible)
10 mm (Ferrule)
SignalingLED signaling
Types of signaling: LED
Signal threshold: > 0,9 x UN (UN = 24VDC) (LED lights up green)
< 0,9 x UN (UN = 24VDC) (LED off)
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4 kV AC (type test)
3.75 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: STEPPOWER
MTBF (IEC 61709, SN 29500): > 1350000 h (25°C)
> 750000 h (40°C)
> 488000 h (50°C)
Environmental protection directive: RoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection class: II (in closed control cabinet)
Degree of pollution: 2
DimensionsItem dimensions
Width: 72 mm
Height: 90 mm
Depth: 61 mm
55 mm (Device depth (DIN rail mounting))
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/056cdb8f3bb36f429a719a72153d4ed2/-S204x204-FJPG
Horizontal pitch: 4 Div. (DIN43880)
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 30 mm / 30 mm
MountingMounting type: DIN rail or direct mounting
Assembly instructions: alignable: 0mm horizontally, 30mm vertically
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsFlammability rating according to UL 94: V0 (Housing, terminal blocks, base latches)
Housing material: Plastic
Polycarbonate
Foot latch material: Polyamid
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -10°C ... 70°C (Derating: >50°C; 2%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Ambient temperature (start-up type tested): -25°C
Maximum altitude: ≤ 4000 m (> 2000m, Derating: 10%/1000m)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock (operation): 18ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsOvervoltage category
EN 61010-1: II(≤4000m)
Overvoltage category​
EN 62477-1: III(≤2000m)
Electrical safety
Standard designation: Electrical safety
Standards/specifications: IEC 61010-1 (SELV)
Protective extra-low voltage
Standard designation: Protective extra-low voltage
Standards/specifications: IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Safe isolation
Standard designation: Safe isolation
Standards/specifications: IEC 61558-2-16
Low-voltage power supplies, DC output
Standard designation: Low-voltage power supplies, DC output
Standards/specifications: EN61204-3
Safety requirements for electrical equipment for measurement, control, and laboratory use
Standard designation: Safety requirements for electrical equipment for measurement, control, and laboratory use
Standards/specifications: IEC 61010-1
Household and similar electrical appliances - Safety
Standard designation: Safety of electrical devices for household use and similar purposes
Standards/specifications: DINEN60335-1
Electric vehicle conductive charging system - Part21-2: EMC requirements for off board electric vehicle charging systems
Standard designation: Electric vehicle conductive charging system - Part21-2: EMC requirements for off board electric vehicle charging systems
Standards/specifications: IEC 61851-21-2
Note: ClassB
ApprovalsUL
Identification: UL/C-UL Listed UL61010-1
UL​
Identification: UL/C-UL Listed UL61010-2-201
UL​​
Identification: UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
Interference emission: Interference emission in accordance with EN61000-6-3 (residential and commercial) and EN61000-6-4 (industrial)
Noise immunity: EN 61000-6-2:2005
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Conducted noise emission: EN55016
EN61000-6-3 (Class B)
Noise emission: EN55016
EN61000-6-3 (Class B)
Harmonic currents
Standards/regulations: EN61000-3-2
EN61000-3-2 (Class A)
Flicker
Standards/regulations: EN61000-3-3
Frequency range: 0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 6 kV (Test Level 3)
Discharge in air: 8 kV (Test Level 3)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 6 GHz
Test field strength: 10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: asymmetrical 4 kV (Test Level 4)
Output: asymmetrical 2 kV (Test Level 3)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: symmetrical 2 kV (Test Level 4)
asymmetrical 4 kV (Test Level 4)
Output: symmetrical 1 kV (Test Level 3)
asymmetrical 2 kV (Test Level 3)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Input/Output: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Voltage dips
Standards/regulations: EN61000-4-11
Voltage: 230 VAC
Frequency: 50 Hz
Voltage dip: 70 %
40 %
0 %
Number of periods: 25 periods
10 periods
1 period
Additional text: Class3
Comments: Criterion A
Criterion B
Criterion A
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Specifiche
ECLASSECLASS-11.0: 27040701
ECLASS-12.0: 27040701
ECLASS-13.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000
Descrizione
Primary-switched power supply unit, STEP POWER, Push-in technology, DIN rail mounting, input: 1-phase, output: 24 V DC / 5 A
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00712.pdf

Approvals_00713.pdf

Data_sheet_00566.pdf

Manufacturer_declaration_03173.pdf

Manufacturer_declaration_04473.pdf

Manufacturer_declaration_05503.pdf

Manufacturer_declaration_05505.pdf

Manufacturer_declaration_06304.pdf

Package_slip_02349.pdf

Technical_drawing_08053.pdf

Various_00006.pdf