Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1190012
PHOENIX CONTACTDisponibile

AXL SE SSDI8/3 - Safety module

Axioline SmartElements, Digital input module, Functional safety, SafetyBridge technology, Safe digital inputs: 4 (2-channel assignment), 8 (1-channel assignment), 24 VDC, connection technology: 3-conductor, degree of protection: IP20
Cod. Articolo: 1190012
Cod. Fornitore: 1190012
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
InterfacesSmartElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartElement.
System propertiesModule
Input address area: 6 Byte
Output address area: 5 Byte
Input dataDigital
Input name: Safe digital inputs
Description of the input: EN 61131-2, type 3
Number of inputs: 4 (2-channel assignment)
8 (1-channel assignment)
Cable length: max. 200 m (200 m from the clock output to the safe input (total based on forward and return path))
Connection method: Push-in connection
Connection technology: 3-conductor
Input voltage range "0" signal: -3 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: typ. 2.7 mA
Input filter time: 1.5 ms
3 ms (Default)
5 ms
15 ms
Protective circuit: Polarity reversal protection of the inputs; Diode
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartElements
Mounting position: any
Application: Functional safety
SafetyBridge technology
Operating mode: SafetyBridge
Insulation characteristics
Overvoltage category: II (IEC 60664-1)
Pollution degree: 2 (EN60664-1)
Electrical propertiesPotentials
Protection: external fusing via the system in which the SmartElement is used
Protective circuit: Surge protection of the supply voltage; electronic (35 V, 0.5 s)
Polarity reversal protection of the supply voltage; via the system in which the SmartElement is used
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 140 mA (at UBus 5VDC)
typ. 101 mA (at UBus 5VDC)
Potentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VDC (using card edge connectors)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 12 mA (Power supply from Up with 30VDC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
typ. 9 mA (Power supply from Up with 24VDC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
Current consumption: min. 8 mA (Power supply from Up with 19.2VDC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
Power consumption: max. 360 mW
min. 154 mW
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Degree of protection at installation location: min. IP54
Air pressure (operation): 70 kPa ... 108 kPa
Air pressure (storage/transport): 66 kPa ... 108 kPa
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
Air clearances and creepage distances
Air clearances and creepage distances: IEC 60664-1
MountingMounting type: Smart Element slot
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00523.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Certification_00369.pdf

Manual_00045.pdf

Manual_00087.pdf

Manufacturer_declaration_01310.pdf

Manufacturer_declaration_02313.pdf

Manufacturer_declaration_06732.pdf

Package_slip_00780.pdf

Product_information_00033.pdf

Product_information_00999.pdf

Technical_drawing_09956.pdf