PHOENIX CONTACT 1213483
PHOENIX CONTACTNon disponibile

AXL P DI16/2 1F - Digital module

Axioline P, Digital input module, Digital inputs: 16, 24 VDC, connection technology: 2-conductor, degree of protection: IP20
Cod. Articolo: 1213483
Cod. Fornitore: 1213483
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/d73c151698d3034692d5b4e99ba38648/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 77.14 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Material specificationsColor: traffic grey A RAL 7042
InterfacesAxioline P local bus
Connection method: Connection for bus base module
Transmission speed: 100 Mbps
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2 types 1 and 3
Number of inputs: 16
Connection method: Push-in connection
Connection technology: 2-conductor
Input voltage range "0" signal: -3 VDC ... 5 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: 2.4 mA
Protective circuit: Polarity reversal protection of the inputs
Product propertiesType: block modular
Product type: I/O component
Product family: Axioline P
Mounting position: any (no temperature derating)
Insulation characteristics
Overvoltage category: II
Pollution degree: 2
Electrical propertiesPotentials: Supply of the logic voltage U
Supply voltage range: 19.2 VDC ... 30 VDC (via bus base module (UL) at AXLPBK...)
Potentials: Supply of the AxiolineP local bus U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 135 mA
Potentials: Axioline P extension module supply voltage
Supply voltage: UL (via bus base module)
Current draw: max. 59 mA (via bus base module)
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 62 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 62 Hz, 1 min.
Test voltage: Field to functional earth: 500 VAC, 62 Hz, 1 min.
Test voltage: Field to 5V and 24V supplies: 1500 VAC, 62 Hz, 1 min.
Connection dataConnection technology
Connection name: Axioline P connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineP: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Axioline P connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineP: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C (Standard)
Air pressure (operation): 70 kPa ... 106 kPa (up to 2000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 2000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
ApprovalsATEX
Identification: II 3G Ex ec IIC T4 Gc
Certificate: DEMKO 20 ATEX 2334X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx UL 20.0002X
UKCAEx(UKEX)
Identification: II 3G Ex ec IIC T4 Gc
Certificate: PxCAI22UKEx1052416X
Ex data
UL, USA / Canada: Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, IIC T4
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Specifiche
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00042.pdf

Approvals_00043.pdf

Approvals_00172.pdf

Approvals_00173.pdf

Approvals_01692.pdf

Approvals_01693.pdf

Certification_00136.pdf

Certification_00137.pdf

Manufacturer_declaration_00326.pdf

Manufacturer_declaration_06818.pdf

Package_slip_00171.pdf

Product_information_00033.pdf

Product_information_01003.pdf

Technical_drawing_10380.pdf