PHOENIX CONTACT 1413297
PHOENIX CONTACTNon disponibile

NBC-P2RM/2,0-1020/P2RM B02 - Network cable

Assembled PROFINET power cable, 24 V, 5 x 2.5 mm2, stranded (50-wire), color: RAL 7001 (silver gray), PPC-MSTB metal to PPC-MSTB metal, length: 2.0 m
Cod. Articolo: 1413297
Cod. Fornitore: 1413297
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Caratteristiche Tecniche
NotesGeneral: This product corresponds to the PROFINET Cabling and Interconnection Technology Guideline for PROFINET regulations, version 2.00, order no: 2.252, Chapter 11 Connectors for 24 Volt Power Supply Cabling and Chapter 13 Application specific Cabling and Interconnection Technology (AIDA)
Product propertiesProduct type: Patch cable
Sensor type: PROFINET/power
Number of positions: 5
Shielded: no
Electrical propertiesNominal voltage UN: 24 V
Material specificationsOuter sheath, material: PVC
Conductor material: Bare Cu litz wires
ConnectorConnection 1
Type: Plug straight MSTB
Degree of protection: IP67
Number of positions: 5
Locking type: Push Pull
Connection 2
Type: Plug straight MSTB
Number of positions: 5
Degree of protection: IP67
Locking type: Push Pull
Cable/lineCable length: 2.00 m
PVC gray[PVC]
Shielded: no
Cable weight: 242 kg/km
Cable type: PVC gray
Cable type (abbreviation): PVC
External cable diameter: 11.8 mm
Outer sheath, material: PVC
External sheath, color: gray RAL 7001
Conductor material: Bare Cu litz wires
Conductor structure, voltage supply: 50x 0.25 mm
Conductor cross section: 5x 2.5 mm²
AWG power supply: 14
Material wire insulation: PVC
Single wire, color: blue, brown, black, gray, green/yellow
Overall twist: 5 cores, twisted
Nominal voltage, cable: 750 V
1000 V (Fixed, protected installation)
Test voltage, cable: 4000 V
Cable insulation resistance: > 0.2 MΩ*km
Minimum bending radius, fixed installation: 4 x D
Minimum bending radius, flexible installation: 15 x D
Flame resistance: according to IEC 60332-1-2
Ambient temperature (operation): -5°C ... 70°C (Cable, flexible installation)
-40°C ... 80°C (cable, fixed installation)
Mechanical propertiesMechanical data
Insertion/withdrawal cycles: ≥ 100
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65/IP67
Ambient temperature (operation): -40°C ... 70°C (cable, fixed installation)
-5°C ... 70°C (Cable, flexible installation)
Specifiche
ECLASSECLASS-11.0: 27060307
ECLASS-12.0: 27060307
ECLASS-13.0: 27060307
ETIMETIM 8.0: EC002599