STEP-PS/ 1AC/ 5DC/2 - Power supply unit

Primary-switched STEP POWER power supply for DIN rail and direct mounting, input: 1-phase, output: 5VDC/2A
Cod. Articolo: 2320513
Cod. Fornitore: 2320513
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Input dataAC operation
Nominal input voltage range: 100 VAC ... 240 VAC
Input voltage range: 85 VAC ... 264 VAC
95 VDC ... 250 VDC
Input voltage range AC: 85 VAC ... 264 VAC
Input voltage range DC: 95 VDC ... 250 VDC
Voltage type of supply voltage: AC/DC
Inrush current: < 15 A
Inrush current integral (I2t): < 0.1 A2s
AC frequency range: 45 Hz ... 65 Hz
Frequency range DC: 0 Hz
Mains buffering time: typ. 25 ms (120VAC)
typ. 110 ms (230 V AC)
Current consumption: 0.2 A (120VAC)
0.13 A (230 V AC)
Nominal power consumption: 28.9 VA
Power factor (cos phi): 0.44
Typical response time: < 0.5 s
Input fuse: 1.25 A (slow-blow, internal)
Permissible DC backup fuse: DC: Connect a suitable fuse upstream
Recommended breaker for input protection: 6 A ... 16 A (AC: Characteristics B, C, D, K)
Output dataEfficiency: > 81 % (for 230 V AC and nominal values)
Output characteristic: U/I
Nominal output voltage: 5 VDC ±1%
Output current Imax: 3.7 A
Nominal output current (IN): 2 A (-25°C...40°C permanent)
2.2 A (-25°C...55°C)
Derating: 55°C ... 70°C (2.5%/K)
Protection against overvoltage at the output (OVP): < 10 VDC
Residual ripple: < 50 mVPP
Output power: 10 W
Maximum no-load power dissipation: < 0.4 W
Power loss nominal load max.: < 2.6 W
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 6.5 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 12
Stripping length: 6.5 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Operating voltage display: Green LED
Signal output: LED status indicator
Status display: "DC OK" LED green
Note on status display: UOUT > 4 V: LED is lit
LED on
Color: green
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4 kV AC (type test)
3.75 kV AC (routine test)
3.75 kV AC (routine test)
4 kV AC (type test)
Insulation voltage output / PE: 500 VDC (routine test)
Insulation voltage input / PE: 3.5 kV AC (type test)
2 kV AC (routine test)
Product propertiesProduct type: Power supply
Product family: STEPPOWER
MTBF (IEC 61709, SN 29500): > 1812000 h (40°C)
Insulation characteristics
Protection class: II (in closed control cabinet)
Overvoltage category: III
Degree of pollution: 2
DimensionsWidth: 18 mm
Height: 90 mm
Depth Device depth (DIN rail mounting): 55 mm (Device depth (DIN rail mounting))
Horizontal pitch: 1 Div.
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 30 mm / 30 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: 0mm horizontally, 30mm vertically
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsHousing material: Plastic
Polycarbonate
Foot latch material: POM (Polyoxymethylene)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsRail applications: EN50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV)
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard - Electrical safety: IEC 62368-1(SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment: EN50178
Standard – Safety extra-low voltage: IEC 62368-1 (SELV) und EN60204-1 (PELV)
Standard - Safe isolation: DINVDE0100-410
Standard - Safety of transformers: EN61558-2-16
ApprovalsUL approvals: UL/C-UL listed UL508
UL/C-UL Recognized UL60950-1
NEC Class 2 as per UL 1310
Conformity/Approvals
SIL in accordance with IEC 61508: 0
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 6 kV (Test Level 3)
Discharge in air: 8 kV (Test Level 3)
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 2 GHz
2 GHz ... 3 GHz
Test field strength: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 2 - symmetrical)
0.5 kV (Test Level 1 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 10 kHz ... 15 kHz
Comments: Criterion A
Voltage: 3 V (Test Level 2)
Voltage dips
Standards/regulations: EN61000-4-11
Emitted interference
Standards/regulations: EN61000-6-3
Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) classB used in industry and residential area / EMC1
Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) class B used in industry and residential area / EMC 1
Specifiche
ECLASSECLASS-11.0: 27040701
ECLASS-13.0: 27040701
ECLASS-12.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00048.pdf

Approvals_00049.pdf

Approvals_00054.pdf

Approvals_00055.pdf

Data_sheet_03120.pdf

Manufacturer_declaration_03048.pdf

Manufacturer_declaration_04615.pdf

Manufacturer_declaration_05504.pdf

Manufacturer_declaration_14315.pdf

Package_slip_02333.pdf

Technical_drawing_37408.pdf

Various_00006.pdf