Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2688598
PHOENIX CONTACT 2688598
PHOENIX CONTACTNon disponibile

AXL F UTH4 1H - Temperature module

AxiolineF, Temperature recording module, Analog inputs: 4 (4 inputs for thermocouples or linear voltage, plus 1 input -5V to +5V), connection technology: 2-conductor (shielded, twisted pair), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and AxiolineF connectors
Cod. Articolo: 2688598
Cod. Fornitore: 2688598
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/172c7c5767999646b422d3edebda44f8/-S204x204-FJPG
Width: 35 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a THÂ35-7.5 DIN rail is used (in accordance with ENÂ60715).
InterfacesAxiolineÂFÂlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 10 Byte
Output address area: 10 Byte
Required parameter data: 12 Byte
Required configuration data: 7 Byte
Input dataAnalog
Input name: Analog inputs
Description of the input: Inputs for thermocouples or linear voltage
Number of inputs: 4 + 1 (4 inputs for thermocouples or linear voltage, plus 1 input -5ÂV to +5ÂV)
Connection method: Spring-cage connection with direct connector-in method
Connection technology: 2-conductor (shielded, twisted pair)
A/D converter resolution: 24 bit
Sensor types (RTD) that can be used: Pt 100 (2 external cold junctions, can also be used as a sensor input)
Measuring principle: Sigma/Delta process
Measured value representation: 16 bits (15 bits + sign bit)
Input filter time: 40 ms
60 ms
100 ms
120 ms (adjustable)
Protective circuit: Short-circuit protection, overload protection of the inputs
Transient protection of inputs
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineÂF
Mounting position: any (no temperature derating)
Scope of delivery: including bus base module and AxiolineÂF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, ENÂ60664-1)
Pollution degree: 2 (IEC 60664-1, ENÂ60664-1)
Electrical propertiesPotentials
Power consumption: typ. 1.05 W (entire device)
max. 1.76 W (entire device)
Potentials: AxiolineÂF local bus supply (U
Supply voltage: 5 VÂDC (via bus base module)
Current draw: max. 160 mA
typ. 112 mA
Power consumption: max. 0.8 W (logic)
typ. 0.54 W (logic)
Potentials: Supply for analog modules (U
Supply voltage: 24 VÂDC
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 40 mA
typ. 23 mA
Power consumption: max. 0.96 W (Peripherals)
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; Polarity protection diode
Transient protection; Suppressor diode
Electrical isolation/isolation of the voltage ranges
Test voltage: 5ÂV supply of the local bus (UBus) / 24ÂV supply (I/Os): 500 VÂAC, 50 Hz, 1 min.
Test voltage: 5ÂV supply of the local bus (UBus) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24ÂV supply (I/O) / functional ground: 500 VÂAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineÂF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“AxiolineÂF: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineÂF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the âہ“AxiolineÂF: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01195.pdf

Approvals_01199.pdf

Approvals_01203.pdf

Approvals_01209.pdf

Approvals_01303.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01758.pdf

Approvals_01777.pdf

Approvals_01836.pdf

Approvals_01893.pdf

Data_sheet_03170.pdf

Manual_00006.pdf

Manual_00007.pdf

Manufacturer_declaration_00741.pdf

Manufacturer_declaration_02172.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Manufacturer_declaration_14410.pdf

Package_slip_00771.pdf

Product_information_00033.pdf

Product_information_00252.pdf

Technical_drawing_37516.pdf

Various_00004.pdf