Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2701295
PHOENIX CONTACT 2701295
PHOENIX CONTACTNon disponibile

AXC 1050 XC - Controller

Axiocontrol for the direct control of Axioline I/Os. With 2 Ethernet interfaces, extended temperature range, and programming options according to IEC 61131-3. Complete with connector connector and marking field.
Cod. Articolo: 2701295
Cod. Fornitore: 2701295
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesType: modular
Product type: Controller
Product family: Axiocontrol
Insulation characteristics
Protection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
Display
Diagnostics display: No
System propertiesProcessor: Altera Nios II 1x 100 MHz
Retentive data storage: 48 kByte (NVRAM)
IEC 61131 runtime system
Program memory: 2 Mbyte
Data storage system: 2 Mbyte
Number of control tasks: 8
Axioline
Amount of process data: max. 8192 bit (per station)
max. 4096 bit (AxiolineÂF local bus (input))
max. 4096 bit (AxiolineÂF local bus (output))
Number of supported devices: max. 63 (per station)
Number of local bus devices that can be connected: max. 63 (observe current consumption)
PROFINET
Device function: PROFINET controller, PROFINET device
Specification: Version 2.3
Update rate: min. 32 ms (16 devices)
min. 32 ms (8 devices)
min. 16 ms (4 devices)
min. 8 ms (2 devices)
min. 4 ms (1Âdevice)
Conformance Class: A
Number of supported devices: max. 16 (at PROFINET controller)
Supported functions: MRP
Device ID: 0093hex
Vendor ID: 00B0hex
Function
Diagnostics display: No
Controller redundancy: yes
Safety function: No
Functionality
Programming languages supported: Instruction list (IL)
Symbolic flowchart (SFC)
Ladder diagram (LD)
Function block diagram (FBD)
Structured text (ST)
System requirements
Engineering tool: PC Worx
PC Worx Express
Configuration tool: Config+ Version 1.01 or later
Diagnostics tool: DIAG+
Runtime system: eCLR
Application interface: OPC
Electrical propertiesReal-time clock
Realtime clock: Yes
Description realtime clock: 1.73 s/day = 20Âppm at 25°C
Potentials
Protective circuit: Surge protection of the supply voltage; electronic
Polarity reversal protection of the supply voltage; electronic
Potentials: Communications power U
Supply voltage: 24 VÂDC
Supply voltage range: 19.2 VÂDC ... 30 VÂDC (including all tolerances, including ripple)
Current draw: max. 650 mA (with 2ÂA at UBus for the I/Os and UL = 24 V)
typ. 100 mA (without I/Os and UL = 24 V)
Power consumption: max. 13.2 W (2.0ÂA on UBus, ULÂ=Â24ÂV)
Potentials: AxiolineÂF local bus supply (U
Supply voltage: 5 VÂDC (via bus base module)
Power supply unit: 2 A
Connection dataConnection method: Push-in connection
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
InterfacesWeb server: yes
AxiolineÂF local bus
Number of interfaces: 1
Connection method: Bus base module
Transmission speed: 100 Mbps
Ethernet
Bus system: RJ45
Number of interfaces: 2
Connection method: RJ45 jack
Note on the connection method: Auto negotiation and autocrossing
Transmission speed: 10/100 Mbps (half or full duplex (automatic detection))
Transmission physics: Ethernet in RJ45 twisted pair
No. of channels: 2
Service
Bus system: USB
Number of interfaces: 1
Connection method: Micro USB type B
Transmission speed: max. 115.2 kbps
No. of channels: 1
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/aad81a7f06bc4f4aa1cf74b52bb32fb4/-S204x204-FJPG
Width: 45 mm
Height: 126.1 mm
Depth: 74 mm
Note on dimensions: The depth applies when a THÂ35-7.5 DIN rail is used (in accordance with ENÂ60715).
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C up to 2000Âm above mean sea level (observe derating)
-40°C ... 65°C up to 3000Âm above mean sea level (observe derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (according to DINÂENÂ61131-2, non-condensing, no ice formation)
Permissible humidity (storage/transport): 5 % ... 95 % (according to DINÂENÂ61131-2, non-condensing, no ice formation)
Shock (operation): 10g (Bump endurance test according to DIN EN 60068-2-27)
Vibration (operation): 5g
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500Âm above mean sea level)
ApprovalsATEX
Identification: ïÃ‹œ II 3 G Ex ec IIC T4 Gc
Certificate: TÃœVÂ21ÂATEXÂ8677ÂX
UKEX
Identification: ïÃ‹œ II 3 G Ex ec IIC T4 Gc
Certificate: PxCIMA23UKEX2701295X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECExÂTURÂ21.0025X
CCCÂ/ÂChina-Ex
Identification: Ex ec IIC T4 Gc
Certificate: , 2023122304116464
UL, USA/Canada
Identification: cULus
Certificate: E238705
Corrosive gas test
Identification: ISAÂS71.04.2013 G3 Harsh Group A,
DINÂENÂ60068-2-60:2016-06 MethodÂ4
EMC dataConformance with EMC directives: Immunity test in accordance with ENÂ61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)ENÂ61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with ENÂ61000-6-2/IEC 61000-6-2 Electromagnetic fieldsENÂ61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with ENÂ61000-6-2/IEC 61000-6-2 Fast transients (burst)ENÂ61000-4-4/IEC 61000-4-4 Criterion B, 2ÂkV
Immunity test in accordance with ENÂ61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)ENÂ61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity test in accordance with ENÂ61000-6-2/IEC 61000-6-2 Conducted interferenceENÂ61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with ENÂ61000-6-3/IEC 61000-6-3 ClassÂB
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
MountingMounting type: DIN rail mounting
Connection method: Push-in connection
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00031.pdf

Application_note_00033.pdf

Application_note_00051.pdf

Application_note_00082.pdf

Application_note_00108.pdf

Application_note_00132.pdf

Application_note_00189.pdf

Approvals_01195.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01684.pdf

Approvals_01700.pdf

Approvals_01701.pdf

Approvals_01756.pdf

Approvals_01777.pdf

Approvals_01803.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Function_blocks_00002.pdf

Function_blocks_00004.pdf

Function_blocks_00006.pdf

Manual_00006.pdf

Manual_00007.pdf

Manual_00132.pdf

Manual_00163.pdf

Manufacturer_declaration_00770.pdf

Manufacturer_declaration_02147.pdf

Manufacturer_declaration_05553.pdf

Manufacturer_declaration_14558.pdf

Package_slip_00623.pdf

Product_information_00033.pdf

Product_information_00291.pdf

Technical_drawing_37693.pdf