AXL E PB DI8 DO4 2A M12 6P - Digital module

AxiolineE, Digital I/O device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 8, 24 VDC, connection technology: 4-conductor, Digital outputs:4, 24 VDC, connection technology:3-conductor, Plastic housing, degree of protection: IP65/IP67
Cod. Articolo: 2701502
Cod. Fornitore: 2701502
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/5b337e318ca1ed41a970b074b0b1c553/-S204x204-FJPG
Width: 60 mm
Height: 185 mm
Depth: 30.5 mm
Drill hole spacing: 198.5 mm
Note on dimensions: The height is 212 mm including fixing clips.
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Material specificationsHousing material: Pocan®
Color: anthracite
InterfacesPROFIBUS DP
Number of interfaces: 2
No. of channels: 2
Connection method: M12 fast connection technology
Note on the connection method: B-coded
Number of positions: 5
Transmission speed: 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
Transmission physics: PROFIBUS-DP-compliant copper cable
Address area assignment: 1 ... 126, adjustable
PROFIBUS DP​
Equipment type: PROFIBUS slave
System-specific protocols: PROFIBUS protocols DP V1
System propertiesModule
ID code (hex): 0E5F
Input address area: 8 bit
Output address area: 8 bit
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2 types 1 and 3
Number of inputs: 8
Cable length: max. 30 m (to the sensor)
Connection method: M12 connector, double occupancy
Connection technology: 4-conductor
Input voltage range "0" signal: 0 V ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: typ. 3 mA
Sensor current per channel: typ. 75 mA (from US)
Total sensor current: max. 0.6 A (per device)
Input filter time: < 1000 µs
Protective circuit: Overload protection, short-circuit protection of sensor supply
Output dataDigital
Output name: Digital outputs
Connection method: M12 connector (A-coded)
Connection technology: 3-conductor
Number of outputs: 4
Protective circuit: Overload protection, short-circuit protection of outputs; yes
Output voltage: 24 VDC
Limitation of the voltage induced on circuit interruption: -28 V ... -17 V
Maximum output current per channel: 2 A
Nominal output voltage: 24 VDC (from voltage UA)
Output voltage range: 18 VDC ... 31.2 VDC
Output voltage when switched off: max. 1 V
Output current when switched off: max. 20 µA
Nominal load, inductive: 48 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, ohmic: 48 W (48 Ω, with nominal voltage)
Switching frequency: max. 5500 per second (with at least 50mA load current)
max. 1 per second (with inductive load)
Reverse voltage resistance to short pulses: Reverse voltage proof
Behavior with overload: Auto restart
Signal delay: max. 150 µs (when switched on)
max. 200 µs (when switched off)
Overcurrent shut-down: min. 2.2 A
Product propertiesType: Stand-Alone
Product type: I/O component
Product family: AxiolineE
Electrical propertiesPotentials
Voltage supply US: 24 VDC
Power supply at US: max. 4 A
Current consumption from US: typ. 8 mA
max. 1.2 A
Supply: Module electronics and sensors
Designation: Supply of module electronics and sensors (US)
Connection method: M12 connector (T-coded)
Number of positions: 4
Supply voltage: 24 VDC
Supply voltage range: 18 VDC ... 31.2 VDC (including all tolerances, including ripple)
Current consumption: typ. 110 mA ±15% (at 24 V DC)
max. 12 A
Supply: Actuators
Designation: Supply of actuators (UA)
Connection method: M12 connector (T-coded)
Number of positions: 4
Supply voltage: 24 VDC
Supply voltage range: 18 VDC ... 31.2 VDC (including all tolerances, including ripple)
Current consumption: typ. 30 mA ±15% (at 24 V DC)
max. 12 A
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/bus connection: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power and sensor supply, digital inputs)/FE: 500 VAC, 50 Hz, 1 min.
Test voltage: Bus connection / FE: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply, digital outputs)/24 V supply (communications power and sensor supply, digital inputs): 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply, digital outputs)/bus connection: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply, digital outputs)/FE: 500 VAC, 50 Hz, 1 min.
Connection dataConnection method: M12 connector
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP65/IP67
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 5 % ... 95 %
Permissible humidity (storage/transport): 5 % ... 95 %
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: Wall mounting
Specifiche
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00180.pdf

Application_note_00039.pdf

Application_note_00040.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01241.pdf

Data_sheet_03274.pdf

Manual_00152.pdf

Manufacturer_declaration_00731.pdf

Manufacturer_declaration_02166.pdf

Manufacturer_declaration_05478.pdf

Manufacturer_declaration_14575.pdf

Package_slip_00658.pdf

Package_slip_00670.pdf

Technical_drawing_37707.pdf

Various_00004.pdf