PHOENIX CONTACT 2967617
PHOENIX CONTACTNon disponibile

PLC-RSC- 12DC/21HC - Relay Module

PLC-INTERFACE, consisting of PLC-BSC.../21 HC basic terminal block with screw connection and plug-in miniature relay for high continuous current, for mounting on DIN rail NS 35/7,5, limiting continuous current up to 10 A, 1 changeover contact, input voltage 12 V DC
Cod. Articolo: 2967617
Cod. Fornitore: 2967617
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: High continuous currents
Operating mode: 100% operating factor
Mechanical service life: 3x 107 cycles
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics​
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 3
Electrical propertiesMaximum power dissipation for nominal condition: 0.4 W
Test voltage (Winding/contact): 4 kV AC (50Hz, 1min., winding/contact)
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 12 VDC
Input voltage range: 10.3 VDC ... 16.8 VDC (20°C)
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 33 mA
Typical response time: 8 ms
Typical release time: 10 ms
Protective circuit: Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 1changeover contact
Type of switch contact: Single contact
Contact material: AgNi
Maximum switching voltage: 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage: 12 V (10mA)
Limiting continuous current: 10 A
6 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Maximum inrush current: 30 A (300ms)
Min. switching current: 10 mA (12V)
Interrupting rating (ohmic load) max.: 240 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2500 VA (for 250 V AC)
Interrupting rating (ohmic load) max. bridged: 144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
1500 VA (for 250 V AC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Switching capacity: 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
6 A (at 24 V, AC15)
6 A (at 120 V, AC15)
6 A (at 250 V, AC15)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.6 Nm ... 0.8 Nm
DimensionsWidth: 14 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT II (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Ambient temperature (operation): -40°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Application_note_00002.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_03379.pdf

Manufacturer_declaration_03380.pdf

Manufacturer_declaration_03597.pdf

Manufacturer_declaration_16946.pdf

Package_slip_01742.pdf

Product_information_00033.pdf

Product_information_00520.pdf

Technical_drawing_41556.pdf