Input data | Nominal input voltage range: 24 VDC Input voltage range: 24 VDC -25%...+40% Wide-range input: no Electric strength, max.: 35 VDC (60 s) Inrush current: typ. 1 A Inrush current integral (I2t): < 0.05 A2s Inrush current limitation: 1 A Mains buffering time: typ. 14 ms (24VDC) Current consumption: 6.9 A (24VDC) Typical response time: 300 ms (from SLEEP MODE) Switch-on time: < 1 s Input fuse: 15 A (slow-blow, internal) Recommended breaker for input protection: 10 A ... 16 A (Characteristic B, C, D, K or comparable) Signal Remote (configurable) Connection labeling: 3.3 + Function: Output power ON/OFF (remote) Default: Output power ON (>40ké/24VDC/open bridge between REM and SGnd) |
Output data | Efficiency: typ. 92.2 % (24VDC) Output characteristic: U/I Advanced Smart HICCUP FUSE MODE Nominal output voltage: 24 VDC Setting range of the output voltage (USet): 24 VDC ... 29.5 VDC (> 24VDC, constant capacity) Nominal output current (IN): 5 A Static Boost (IStat.Boost): 6.25 A Dynamic Boost (IDyn.Boost): 10 A (5 s) Selective Fuse Breaking (ISFB): 30 A (15 ms) Magnetic circuit breaker tripping: A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4 Short-circuit-proof: yes No-load proof: yes Output power (PN): 120 W Output power (PStat. Boost): 150 W Output power (PDyn. Boost): 240 W (5 s) Feedback voltage resistance: ⤠35 VDC Protection against overvoltage at the output (OVP): ⤠32 VDC Residual ripple: < 10 mVPP Control deviation: < 1 % (change in load, static 10 % ... 90 %) Rise time: < 100 ms (UOUT (10 % ... 90 %)) Connection in series: yes Maximum no-load power dissipation: < 2 W Power loss nominal load max.: < 10 W Power dissipation SLEEP MODE: < 1 W Connection in parallel: yes, for redundancy and increased capacity Signal Out 1 (configurable) Connection labeling: 3.5 + Digital: 0 VDC 24 VDC 20 mA Signal option: Output voltage Output current Output power Operating hours Early warning of high temperatures OVP voltage limitation active Default: UIN input voltage OK Signal Out 2 (configurable) Connection labeling: 3.6 + Digital: 0 VDC 24 VDC 20 mA Default: Output power Signal option: Output voltage Output current Operating hours Early warning of high temperatures OVP voltage limitation active Output voltage Output current Output power Analog: 4 mA ... 20 mA ±5% (Load â¤400é) Signal relay 13/14 (configurable) Connection labeling: 3.1, 3.2 Switch contact (floating): floating Maximum contact load: 24 VDC 1 A 30 VAC 0.5 A Default: Output voltage Signal option: Output current Output power Operating hours Early warning of high temperatures OVP voltage limitation active UIN input voltage OK Signal ground SGnd Connection labeling: 3.4 + Function: Signal ground Reference potential: to OUT1, OUT2, REM |
Connection data | Input Position: 1.x Conductor connection Connection method: Screw connection rigid: 0.2 mm² ... 6 mm² flexible: 0.2 mm² ... 6 mm² flexible with ferrule without plastic sleeve: 0.2 mm² ... 4 mm² flexible with ferrule with plastic sleeve: 0.2 mm² ... 4 mm² rigid (AWG): 24 ... 10 Stripping length: 10 mm Drive form screw head: Slotted L Output Position: 2.x Conductor connectionâ Connection method: Screw connection rigid: 0.2 mm² ... 6 mm² flexible: 0.2 mm² ... 6 mm² flexible with ferrule without plastic sleeve: 0.2 mm² ... 4 mm² flexible with ferrule with plastic sleeve: 0.2 mm² ... 4 mm² rigid (AWG): 24 ... 10 Stripping length: 10 mm Drive form screw head: Slotted L Signal Position: 3.x Conductor connectionââ Connection method: Push-in connection rigid: 0.2 mm² ... 1 mm² flexible: 0.2 mm² ... 1.5 mm² flexible with ferrule without plastic sleeve: 0.2 mm² ... 1.5 mm² flexible with ferrule with plastic sleeve: 0.2 mm² ... 0.75 mm² rigid (AWG): 24 ... 16 Stripping length: 8 mm |
Signaling | LED signaling Types of signaling: LED Floating signal contact Active signal output Out1 (digital, configurable) Active signal output Out2 (analog, configurable) Remote contact Signal ground SGnd Signal threshold: > 100% (LED lights up yellow, output power > 120W) > 75% (LED lights up green, output power > 90W) > 50% (LED lights up green, output power > 60W) > 0.9xUSet (LED lights up green) < 0.9xUSet (LED flashes green) > 0.8 x UInNom (LED off) < 0.8 x UInNom (LED lights up yellow) |
Electrical properties | Number of phases: 1.00 Insulation voltage input/output: 4 kV DC (type test) 2 kV DC (routine test) Switching frequency: 190 kHz ... 220 kHz (Auxiliary converter stage) 50 kHz ... 420 kHz (Main converter stage) |
Product properties | Product type: DC/DC converters Product family: QUINT POWER MTBF (IEC 61709, SN 29500): > 1600000 h (25°C) > 930000 h (40°C) > 380000 h (60°C) Insulation characteristics Protection class: Special with SELV input and output Degree of pollution: 2 Life expectancy (electrolytic capacitors) Current: 2.5 A Temperature: 40°C Time: 422000 h Additional text: 24VDC Life expectancy (electrolytic capacitors)â Current: 5 A Temperature: 40°C Time: 260000 h Additional text: 24VDC Life expectancy (electrolytic capacitors)ââ Current: 5 A Temperature: 30°C Time: 520000 h Additional text: 24VDC |
Dimensions | Item dimensions Width: 36 mm Height: 130 mm Depth: 125 mm Item dimensions with alternative mounting Width: 122 mm Height: 130 mm Depth: 39 mm Installation dimensions Installation distance right/left (active): 15 mm / 15 mm (⤠70°C) Installation distance right/left (passive): 0 mm / 0 mm (⤠70°C) Installation distance top/bottom (active): 50 mm / 50 mm (⤠70°C) Installation distance top/bottom (passive): 50 mm / 50 mm (⤠70°C) |
Mounting | Mounting type: DIN rail mounting Assembly instructions: alignable: PN â¥50%, 5mm horizontally, 15mm next to active components, 50mm vertically alignable: PN <50%, 0mm horizontally, 40mm vertically top, 20 mm vertically bottom With protective coating: No |
Material specifications | Flammability rating according to UL94 (housing / terminal blocks): V0 Housing material: Metal Hood version: Stainless steel X6Cr17 Side element version: Aluminum |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K) Ambient temperature (storage/transport): -40°C ... 85°C Ambient temperature (start-up type tested): -40°C Maximum altitude: ⤠5000 m (> 2000 m, observe derating) Climatic class: 3K22 (in accordance with EN60721-3-3) Max. permissible relative humidity (operation): ⤠95 % (at 25°C, non-condensing) Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation): 5Hz ... 100Hz resonance search 2.3g, 90min., resonance frequency 2.3g, 90min. (according to DNV GL Class C) |
Standards and regulations | Overvoltage category EN 61010-1: II(â¤5000m) EN 62477-1: III(â¤5000m) Safety for measurement, control, and laboratory equipment Standard designation: Electrical safety (of control and regulation devices) Standards/specifications: IEC 61010-1 Protective extra-low voltage Standard designation: Protective extra-low voltage Standards/specifications: EN61010-1 (SELV) IEC 61010-2-201 (PELV) Mains voltage dips Standard designation: Mains variation/undervoltage Standards/specifications: EN61000-4-29 Railway applications Standard designation: Railway applications Standards/specifications: EN50121-3-2 IEC 62236-3-2 |
Approvals | UL Identification: ULListedUL61010-1 ULâ Identification: ULListedUL61010-2-201 ULââ Identification: UL121201 & CSAC22.2No.213-17Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) CSA Identification: CAN/CSA-C22.2 No.61010-1-12 CSAâ Identification: CAN/CSAC22.2No.61010-2-201:18 SIQ Identification: Type tested (type approved) SIQâ Identification: CB scheme (IEC 61010-1, IEC 61010-2-201) Shipbuilding Identification: DNV Shipbuildingâ Identification: ABS Shipbuildingââ Identification: BV Shipbuildingâââ Identification: NK Shipbuildingââââ Identification: LR |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC EMC requirements for noise emission: EN61000-6-3 EN61000-6-4 EMC requirements for noise immunity: EN61000-6-1 EN61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU EMC requirements, power plant: IEC 61850-3 EN61000-6-5 Conducted noise emission: EN55016 EN61000-6-3 (Class B) Noise emission: Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) EN55016 EN61000-6-3 (Class B) DNVGL conducted interference: ClassB Additional text: Bridge and deck area DNVGL noise radiation: ClassB Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: 8 kV (Test Level 4) Discharge in air: 15 kV (Test Level 4) Comments: Criterion A Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 6 GHz Test field strength: 20 V/m (Test Level 3) 10 V/m (Test Level 3) Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 2 kV (Test Level 3 - asymmetrical) Output: 2 kV (Test Level 3 - asymmetrical) Signal: 2 kV (Test Level 4 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: EN61000-4-5 Input: 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Output: 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal: 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ I/O/S: asymmetrical Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Power frequency magnetic field Standards/regulations: EN61000-4-8 Frequency: 16.7 Hz 50 Hz 60 Hz 50 Hz 60 Hz 0 Hz Test field strength: 100 A/m 1 kA/m 300 A/m Additional text: 60 s 3 s DC, 60s Comments: Criterion A Frequency range: 50 Hz ... 60 Hz Voltage dips Standards/regulations: EN61000-4-29 Voltage: 24 VDC Voltage dip: 70 % 40 % 0 % Time: 100 ms 50 ms Additional text: Test Level 2 Comments: Criterion A Criterion B Criterion B Pulse-shape magnetic field Standards/regulations: EN61000-4-9 Test field strength: 1000 A/m Comments: Criterion A Asymmetrical conducted disturbance variables Standards/regulations: EN61000-4-16 Test level 1: 15 Hz 150 Hz (Test Level 3) Voltage: 10 V 1 V 1 V 1 V 10 V 10 V 10 V (Permanent) 100 V (1 s) Test level 2: 150 Hz 1.5 kHz (Test Level 3) Test level 3: 1.5 kHz 15 kHz (Test Level 3) Test level 4: 15 kHz 150 kHz (Test Level 3) Test level 5: 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) Test level 6: 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3) Comments: Criterion A Alternating component of direct voltage Standards/regulations: EN61000-4-17 Alternating component: 15 % (UN) 14 % (UN) Frequency: 50 Hz 100 Hz 150 Hz 300 Hz Comments: Criterion A Attenuated oscillating wave Standards/regulations: EN61000-4-18 Input, output (test level1): 100 kHz 1 MHz (Test Level 2 - symmetrical) Voltage: 0.5 kV 1 kV 0.5 kV 0.5 kV 1 kV Input, output (test level2): 100 kHz 1 MHz (Test Level 2 - asymmetrical) Input, output (test level3): 10 MHz (Test Level 2 - asymmetrical) Signals (test level1): 100 kHz 1 MHz (Test Level 2 - symmetrical) Signals (test level2): 100 kHz 1 MHz (Test Level 2 - asymmetrical) Comments: Criterion A Attenuated oscillating magnetic field Standards/regulations: EN61000-4-10 Test field strength: 100 A/m Test level 1: 100 kHz Test level 2: 1 MHz Comments: Criterion A Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
ECLASS | ECLASS-11.0: 27040701 ECLASS-12.0: 27040701 ECLASS-13.0: 27040701 |
ETIM | ETIM 9.0: EC002540 |
UNSPSC | UNSPSC 21.0: 39121000 |