Industrial Automation
Notes | General: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g.by using cable ties. Unused slots are to be sealed off prior to commissioning. Suitable sealing elements are to be found under "Accessories". |
Product properties | Product type: Distributor boxes with M8 to M12 slots Number of positions: 5 Application: Robots and drag chains Number of slots: 8 Coding: A |
Material specifications | Material: Die-cast zinc PBT PUR Flammability rating according to UL 94: V0 Seal material O-ring: NBR Contact material: Cu alloy Contact surface material: gold-plated Contact carrier material: PA |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/6dd99cf629b6f84ab87595bf3e209607/-S204x204-FJPG Width: 58 mm Height: 26 mm Length: 153 mm |
Connection data | Conductor connection Connection method: Fixed connection Tightening torque slot sensor/actuator cable: 0.4 Nm Tightening torque of mounting screw for fixing the housing: 0.5 Nm Pin assignment Slot/position = Wire color or connection: 1 / 4 (A)=WH 1 / 2 (B)=GYPK 2 / 4 (A)=GN 2 / 2 (B)=RDBU 3 / 4 (A)=YE 3 / 2 (B)=WHGN 4 / 4 (A)=GY 4 / 2 (B)=BNGN 5 / 4 (A)=PK 5 / 2 (B)=WHYE 6 / 4 (A)=RD 6 / 2 (B)=YEBN 7 / 4 (A)=BK 7 / 2 (B)=WHGY 8 / 4 (A)=VT 8 / 2 (B)=GYBN 1-8 / 1 (+ 24 V)=BN 1-8 / 3 (0 V)=BU 1-8 / 5 (PE)=GNYE |
Signaling | Status display present: Yes |
Electrical properties | Max. operating voltage Umax: 30 VDC Nominal voltage UN: 24 VDC Rated current, total: 12 A Max. current carrying capacity per path: 2 A Current carrying capacity per slot: 4 A |
Cable/line | Cable length: 5 m PUR halogen-free, highly flexible[80MC] Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/16aff763bc5ac44b9a0b8456a250d542/-S204x204-FJPG Number of positions: 19 Shielded: no Cable type: PUR halogen-free, highly flexible[80MC] Conductor structure signal line: 28x 0.15 mm AWG signal line: 20 Conductor cross section: 16x 0.5 mm² (Signal line) 3x 1 mm² (power line) External cable diameter: 10.75 mm Outer sheath, material: PUR External sheath, color: black RAL9005 Conductor material: Bare Cu litz wires Material wire insulation: PP Single wire, color: brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown, white/gray, gray/brown Overall twist: Wires twisted to an optimum in two layers Max. conductor resistance: 39 é/km (Signal line) 19.5 é/m (power line) Insulation resistance: ⥠10 Mé*km (at 20°C) Nominal voltage, cable: 300 V Test voltage: 2000 V Smallest bending radius, fixed installation: 90 mm Smallest bending radius, movable installation: 120 mm Max. bending cycles: 5000000 Torsion force: ± 120°/m Torsion cycles: ⥠3000000 Halogen-free: The cable is halogen-free Flame resistance: DINEN50265-2-1 Resistance to oil: in accordance with DINEN60811-2-1 Other resistance: somewhat resistant to welding sparks Special properties: Silicone-free Free of substances which would hinder coating with paint or varnish Ambient temperature (operation): -30°C ... 70°C (cable, fixed installation) 5°C ... 70°C (Cable, flexible installation) to 80°C (in acc. with UL) |
Standards and regulations | M12 Standard designation: M12 connector Standards/specifications: IEC 61076-2-101 |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP65 IP67 IP69K Ambient temperature (operation): -30°C ... 90°C |
ECLASS | ECLASS-11.0: 27440108 ECLASS-12.0: 27440108 ECLASS-13.0: 27440108 |
ETIM | ETIM 9.0: EC002585 |
UNSPSC | UNSPSC 21.0: 31251500 |