PHOENIX CONTACT 1423962
PHOENIX CONTACTNot available

HC-M-05L-TPT-F - Contact insert module

Contact insert module, number of positions: 5, power contacts: 5, control contacts: 0, number of connections per position: 2, Socket, Push-in connection, 230 V/400 V, 16 A, 0.25 mm2...1.5 mm2, application: Power
Product Code: 1423962
Partner cod.: 1423962
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral: Use only flexible conductors with ferrule (in conjunction with CRIMPFOX 6 only)
Connectors may be operated only when there is no load/voltage.
For HEAVYCON housing type B6 to B48, HC-M-B...MF-... hinged module carrier frame required.
MountingAssembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required
Connection method: Push-in connection
Product propertiesProduct type: Modular contact insert
Number of positions: 5
Connection profile: 5
Contact numbering: 1 - 5
Application: Power
Number of connections per position: 2
Number of module slots: 1
No. of power contacts: 5
No. of control contacts: 0
Contact material type: rolled
Series: HC-M-05-T
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Connection dataConnection technology
Connection technology: Push-in connection
Number of connections per position: 2
Conductor connection
Conductor cross section: 0.25 mm² ... 1.5 mm²
Connection cross section AWG: 24 ... 16
Stripping length of the individual wire: 8 mm ±1mm
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/73f4096c6b161346934b9ddc110afc88/-S204x204-FJPG
Width: 34 mm
Height: 38 mm
Length: 14.6 mm
Mechanical characteristics
Contact diameter: 2.5 mm
Electrical propertiesRated voltage (III/3): 230 V (Conductor-PE)
400 V (Conductor-Conductor)
Rated voltage for power contacts: 230/400 V
Rated surge voltage: 4 kV
Rated current: 16 A
Mechanical propertiesMechanical data
Insertion/withdrawal cycles: ≥ 500
Material specificationsFlammability rating according to UL 94: V0
Contact material: Copper alloy
Contact surface material: Ag
Contact carrier material: PA
Standards/regulations: PA: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -40°C ... 125°C
Standards and regulationsConstructional and testing regulations: DINEN61984
DINEN60664
Tests: DINEN61984
DINEN60664
Testing
Standards/regulations: PA: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3)
Technical Specs
ECLASSECLASS-11.0: 27440217
ECLASS-12.0: 27440217
ECLASS-13.0: 27440217
ETIMETIM 9.0: EC000438
UNSPSCUNSPSC 21.0: 39121400