MCR-SL-CUC-200-I - Universal current transducer

Universal current transducer, for measuring AC, DC, and distorted currents, 0 ... 200 A input current, 4 ... 20 mA output
Product Code: 2308030
Partner cod.: 2308030
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
Product propertiesProduct type: Current transducer
Insulation characteristics
Overvoltage category: III
Pollution degree: 2
Electrical propertiesLinearity error: <± 1 % (From the range end value)
Maximum power dissipation for nominal condition: 1 W
Step response (10-90%): 150 ms
Temperature coefficient, typical: 0.02 %/K (0°C...60°C)
0.04 %/K (-40°C...65°C)
Maximum transmission error: <± 1 % (of final value)
Rated insulation voltage: 300 VAC
Electrical isolation Input/output
Test voltage: 3.5 kV AC (50Hz, 60s)
Electrical isolation Input/power supply
Test voltage: 3.5 kV AC (50Hz, 60s)
General
Accuracy class: 1
Supply
Nominal supply voltage: 24 VDC
Supply voltage range: 20 VDC ... 30 VDC
Max. current consumption: (30 + IOUT) mA
Power consumption: 1.65 W
Input dataMeasurement
Number of inputs: 1
Input current range: 0 A AC/DC ... 200 A AC/DC
Overload capacity: 3 x IIN
Frequency measuring range: 20 Hz ... 6000 Hz (0Hz)
Curve type: AC, DC or distorted currents
Current transformers
Rated frequency: Standard converter: 20 Hz ... 6000 Hz
Primary rated current Ipn: 200 A
Accuracy class: 1
Output dataSignal: Current
Current output signal: 4 mA ... 20 mA
Max. current output signal: < 25 mA
Load/output load current output: < 300 Ω
Connection dataConnection method: Push-in connection
Through connection
Stripping length: 10 mm
Conductor cross section rigid: 0.25 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
DimensionsItem dimensions
Width: 90 mm
Height: 33.8 mm
Depth: 85 mm
Circular conductor
Diameter: 32 mm
Material specificationsHousing material: Frianyl B63 V0 GV30
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA/Canada
Identification: UL/C-UL Listed UL 508
EMC dataNoise immunity: EN 61000-6-2
Noise emission: EN 61000-6-4
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27210123
ECLASS-13.0: 27210123
ECLASS-12.0: 27210123
ETIMETIM 9.0: EC002475
UNSPSCUNSPSC 21.0: 39121000
Description
Universal current transducer, for measuring AC, DC, and distorted currents, 0 ... 200 A input current, 4 ... 20 mA output
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00054.pdf

Approvals_00055.pdf

Data_sheet_03063.pdf

Manufacturer_declaration_01830.pdf

Manufacturer_declaration_04582.pdf

Manufacturer_declaration_18072.pdf

Package_slip_01587.pdf

Technical_drawing_37229.pdf