PHOENIX CONTACT 2313478
PHOENIX CONTACTNot available

FL COMSERVER BASIC 232/422/485 - Interface converters

Second generation FL COMSERVER BASIC..., serial device server for converting a serial RS-232/422/485 interface to Ethernet, only supports TCP and UDP applications, incl. Com Port Redirector software and user documentation (PDF)
Product Code: 2313478
Partner cod.: 2313478
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Description
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Interface converter
Application: TCP, UDP
MTTF: 2001 Years (SN29500 standard, temperature25°C, operating cycle21%)
870 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
355 Years (SN29500 standard, temperature40°C, operating cycle100%)
MTBF: 666 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
179 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
System propertiesSystem requirements
Supported browsers: Netscape Communicator versions 4.5 and up or Internet Explorer versions 5.5 and up
Electrical propertiesElectrical isolation: VCC // Ethernet // Serial
Maximum power dissipation for nominal condition: 2.4 W
Test voltage data interface/data interface: 1.5 kVrms (50Hz, 1min.)
Test voltage data interface/power supply: 1.5 kVrms (50Hz, 1min.)
1.5 kVrms
Supply
Supply voltage range: 19.2 V AC/DC ... 28.8 V AC/DC (via pluggable COMBICON screw terminal block)
22.8 VDC ... 25.2 VDC (as an alternative or redundant, via backplane bus contact and system current supply)
Nominal supply voltage: 24 V AC/DC ±20% (via pluggable COMBICON screw terminal block)
24 VDC ±5% (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption: 100 mA (24VDC)
Function
Management: Web-based management, SNMP, emergency exit with Telnet and serial
Status and diagnostic indicators: LEDs: UL (logic voltage), TD + RD (data activity serial), FD (full duplex), 100 (100 Mbps mode), Link (Ethernet), Activity (Ethernet), ERR (error)
Connection dataSupply
Tightening torque: 0.56 Nm ... 0.79 Nm
InterfacesSignal: Ethernet
Web server: yes
Data: Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
Serial transmission speed: 10/100 Mbps, auto negotiation
Connection method: RJ45 jack, shielded
No. of channels: 1
Transmission length: ≤ 100 m (shielded twisted pair)
Protocols supported: TCP/IP, UDP
Auxiliary protocols: ARP, DHCP, BOOTP, SNMP, RIP, RARP, HTTP, TFTP, ICMP
Data: V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN66259-1
Serial transmission speed: 0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4 kbps
Connection method: D-SUB9 plug
Pin assignment: DTE/DCE switchover via web-based management
Transmission length: 15 m
File format/coding: UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Data flow control/protocols: Software handshake, Xon/Xoff or hardware handshake RTS/CTS
Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Serial transmission speed: 0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500; 1000 kbps
Connection method: Plug-in/screw connection via COMBICON
Transmission length: ≤ 1200 m
Termination resistor: 390 Ω (configurable)
180 Ω
390 Ω
File format/coding: UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Data flow control/protocols: Automatic control
Data: RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
Serial transmission speed: 0.3; 0.6; 1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 38.4; 57.6; 115.2; 187.5; 230.4; 500; 1000 kbps
Connection method: Plug-in/screw connection via COMBICON
Termination resistor: 390 Ω (configurable)
180 Ω
390 Ω
File format/coding: UART/NRZ: 7/8 Bit Data, 1/2 Bit Stopp, None/Even/Odd Parity
Data flow control/protocols: Automatic control
DimensionsWidth: 22.5 mm
Height: 99 mm
Depth: 116 mm
Material specificationsMaterial: PA 6.6-FR
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C
-20°C ... 60°C (in acc. with UL)
Ambient temperature (storage/transport): -25°C ... 70°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
ApprovalsCE
Certificate: CE-compliant
EAC
Identification: EAC
ATEX
Identification:  II 3G Ex nA IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: 508 Listed
Class I, Div. 2, Groups A, B, C, D
UL, USA
Identification: Class I, Zone 2, AEx nA IIC T5
UL, Canada
Identification: Class I, Zone 2, Ex nA IIC T5 Gc X
KC approval for South Korea
Certificate: KCC-REI-PCK-FL2313478
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
EMC dataNoise immunity: EN 61000-6-2:2005
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Noise emission: EN 61000-6-4
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV
Discharge in air: ± 8 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 2 kV (5kHz)
Signal: 1 kV (5kHz)
Comments: Criterion A
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: 2 kV
Signal: 1 kV
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55032
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
Standards/regulations: EN50121-4
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 27242208
ECLASS-12.0: 27242208
ECLASS-13.0: 27242208
ETIMETIM 9.0: EC001423
UNSPSCUNSPSC 21.0: 43222600
Description
Second generation FL COMSERVER BASIC..., serial device server for converting a serial RS-232/422/485 interface to Ethernet, only supports TCP and UDP applications, incl. Com Port Redirector software and user documentation (PDF)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00110.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01261.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Data_sheet_03071.pdf

Manual_00117.pdf

Manufacturer_declaration_00571.pdf

Manufacturer_declaration_05543.pdf

Manufacturer_declaration_14221.pdf

Manufacturer_declaration_17707.pdf

Package_slip_01084.pdf

Technical_drawing_37251.pdf

Various_00062.pdf

Various_00059.pdf

Various_00058.pdf

Various_00063.pdf

Various_00060.pdf

Various_00054.pdf

Various_00057.pdf

Various_00003.pdf

Various_00065.pdf

Various_00055.pdf

Various_00061.pdf

Various_00056.pdf