PHOENIX CONTACT 2702006
PHOENIX CONTACT 2702006
PHOENIX CONTACTNot available

AXL F RS UNI XC 1H - Communication module

AxiolineF, Communication module, interface RS-232, RS-485, RS-422:1, Extremeconditions version, transmission speed in the local bus:100 Mbps, degree of protection:IP20, including bus base module and AxiolineF connectors
Product Code: 2702006
Partner cod.: 2702006
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/172c7c5767999646b422d3edebda44f8/-S204x204-FJPG
Width: 35 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
RS-232, RS-485, RS-422
Number of interfaces: 1
Connection method: Push-in connection
Transmission speed: 110 bps ... 250 kbps (can be parameterized)
Transmission physics: Copper
Protocols supported: Transparent, end-to-end, XON/XOFF, Modbus/RTU (client support)
Termination resistor: active, integrated
Data bits: 5 ... 8
Stop bits: 1 or 2
Input buffer: 4 kByte
Output buffer: 1 kByte
System propertiesModule
Input address area: 20 Byte
Output address area: 20 Byte
Required parameter data: 14 Byte
Required configuration data: 7 Byte
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (no temperature derating)
Scope of delivery: including bus base module and AxiolineF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesPotentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 240 mA
typ. 200 mA
Power consumption: max. 1.2 W
typ. 1 W
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / 5V supply (I/Os): 1000 VDC, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 1000 VDC, 1 min.
Test voltage: 5V supply (I/O)/functional ground: 1000 VDC, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C (Standard, applications with UL approval, use in zone2 potentially explosive area)
-40°C ... 70°C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
ApprovalsATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: UL 20 ATEX 2441X
UKEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: PxCIMA22UKEX2701949X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECEx ULD 20.0026X
UL, USA/Canada
Identification: cULus
Certificate: E238705
UL Ex, USA / Canada
Identification: Class I, Zone 2, AEx ec IIC T4
ClassI, Division2, Groups A, B, C, D, T4
Ex ec IIC T4 Gc X
Certificate: E366272
CCC/China-Ex
Identification: Ex ec IIC T4 Gc
Certificate: , 2021122309114456
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Technical Specs
ECLASSECLASS-11.0: 27242608
ECLASS-12.0: 27242608
ECLASS-13.0: 27242608
ETIMETIM 9.0: EC001604
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00033.pdf

Approvals_01195.pdf

Approvals_01203.pdf

Approvals_01209.pdf

Approvals_01303.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01469.pdf

Approvals_01470.pdf

Approvals_01680.pdf

Approvals_01759.pdf

Approvals_01777.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Approvals_01893.pdf

Approvals_01955.pdf

Data_sheet_03308.pdf

Manual_00006.pdf

Manual_00007.pdf

Manufacturer_declaration_01314.pdf

Manufacturer_declaration_03280.pdf

Manufacturer_declaration_05479.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_14617.pdf

Package_slip_00758.pdf

Package_slip_00759.pdf

Product_information_00033.pdf

Product_information_00304.pdf

Product_information_00305.pdf

Technical_drawing_37744.pdf

Various_00004.pdf