Industrial Automation
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/97375d412c926547bb2e1a41b7a47993/-S204x204-FJPG Width: 35 mm Height: 129.9 mm Depth: 54 mm Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715). |
Interfaces | AxiolineFlocal bus Number of interfaces: 2 Connection method: Bus base module Transmission speed: 100 Mbps |
System properties | Module ID code (hex): none Input address area: 1 Byte Output address area: 1 Byte Required parameter data: 3 Byte Required configuration data: 7 Byte |
Input data | Digital Input name: Digital inputs Description of the input: EN 61131-2 types 1 and 3 Number of inputs: 8 Connection method: Push-in connection Connection technology: 3-conductor Input voltage range "0" signal: -3 VDC ... 5 VDC Input voltage range "1" signal: 11 VDC ... 30 VDC Nominal input voltage UIN: 24 VDC Nominal input current at UIN: 2.4 mA Input filter time: 3000 µs (Default) 1000 µs < 100 µs Protective circuit: Polarity reversal protection of the inputs; parallel diode (30V, 5s) |
Output data | Digital Output name: Digital outputs Connection method: Push-in connection Connection technology: 3-conductor Number of outputs: 8 Protective circuit: Short-circuit protection, overload protection of the outputs; electronic Output voltage: 24 VDC Limitation of the voltage induced on circuit interruption: -25.8 V ... -15 V Maximum output current per module: max. 8 A (provide external protection) Nominal output voltage: 24 VDC Load min.: 10 ké Output voltage when switched off: max. 1 V Output current when switched off: max. 300 µA Nominal load, inductive: max. 12 VA (1.2 H, 48 é, with nominal voltage) Nominal load, lamp: max. 12 W (at nominal voltage) Nominal load, ohmic: max. 12 W (48 é, with nominal voltage) Switching frequency: max. 10000 per second (with at least 50mA load current) max. 1 per second (with inductive load) max. 16 per second (with nominal lamp load) Reverse voltage resistance to short pulses: limited protection up to 0.5 A for 1 s Behavior with overload: Shutdown with automatic restart Behavior with inductive overload: Output can be destroyed Signal delay: max. 100 µs (when switched on) max. 100 µs (when switched off, with at least 50 mA load current) Overcurrent shut-down: as of 0.7 A Output current with ground connection interrupt when switched off: < 1 mA |
Product properties | Type: block modular Product type: I/O component Product family: AxiolineF Mounting position: any (no temperature derating) Scope of delivery: including bus base module and AxiolineF connectors Insulation characteristics Overvoltage category: II (IEC 60664-1, EN60664-1) Pollution degree: 2 (IEC 60664-1, EN60664-1) |
Electrical properties | Potentials: AxiolineF local bus supply (U Supply voltage: 5 VDC (via bus base module) Current draw: max. 120 mA (up to HW01) max. 60 mA (from HW02) Power consumption: max. 600 mW (up to HW01) max. 300 mW (from HW02) Potentials: Supply for digital input and output modules (U Supply voltage: 24 VDC Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple) Current draw: max. 6 A (provide external protection) Power consumption: max. 180 W (of which 1.24W internal losses) Protective circuit: Surge protection; electronic (35 V, 0.5 s) Reverse polarity protection; parallel diode; with external 5A fuse (only for commissioning) Supply: Sensor supply (US) Designation: Sensor supply (US) Supply voltage: 24 VDC (from UIO) Electrical isolation/isolation of the voltage ranges Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min. Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min. Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min. |
Connection data | Connection technology Connection name: AxiolineF connector Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineF: system and installationâ user manual. Conductor connection Connection method: Push-in connection Conductor cross section rigid: 0.2 mm² ... 1.5 mm² Conductor cross section flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm AxiolineF connector Connection method: Push-in connection Note on the connection method: Please observe the information provided on conductor cross sections in the âAxiolineF: system and installationâ user manual. Conductor cross section, rigid: 0.2 mm² ... 1.5 mm² Conductor cross section, flexible: 0.2 mm² ... 1.5 mm² Conductor cross section AWG: 24 ... 16 Stripping length: 8 mm |
Environmental and real-life conditions | Ambient conditions Ambient temperature (operation): -25°C ... 60°C Degree of protection: IP20 Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level) Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level) Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing) |
Standards and regulations | Protection class: III (IEC 61140, EN61140, VDE0140-1) |
Mounting | Mounting type: DIN rail mounting Mounting position: any (no temperature derating) |
ECLASS | ECLASS-11.0: 27242604 ECLASS-12.0: 27242604 ECLASS-13.0: 27242604 |
ETIM | ETIM 9.0: EC001599 |
UNSPSC | UNSPSC 21.0: 32151600 |