PHOENIX CONTACT 2702636
PHOENIX CONTACTNot available

PSI-TERMINATOR-PB-TBUS - Termination resistor

Active termination resistor for PROFIBUS and RS-485 bus systems, redundant power supply, routing of the supply voltage via DIN rail connector, electrical isolation, switchable termination, integrated programming interface
Product Code: 2702636
Partner cod.: 2702636
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction​
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Terminal resistor
MTTF: 3305 Years (SN29500 standard, temperature25°C, operating cycle21%)
1923 Years (SN29500 standard, temperature40°C, operating cycle34.25%)
911 Years (SN29500 standard, temperature40°C, operating cycle100%)
Insulation characteristics
Overvoltage category: II
Insulation characteristics​
Pollution degree: 2
Electrical propertiesElectrical isolation: RS-485 // VCC
Maximum power dissipation for nominal condition: 0.24 W
Test voltage data interface/power supply: 1.5 kV AC (50Hz, 1min.)
Supply
Supply voltage range: 18 VDC ... 30 VDC (via pluggable COMBICON screw terminal block)
Nominal supply voltage: 24 VDC (via pluggable COMBICON screw terminal block)
Typical current consumption: 10 mA (24 V DC, no load on D-SUB)
60 mA (24 V DC, current drain at D-SUB of 150 mA)
Max. current consumption: 12 mA (18 V DC, no load on D-SUB)
77 mA (18 V DC, current drain at D-SUB of 150 mA)
Function
Status and diagnostic indicators: LEDs: US (power supply), ACT (data activity)
Connection dataSupply
Single conductor/terminal point, rigid: 0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]: 24 ... 12
Tightening torque: 0.6 Nm ... 0.8 Nm
InterfacesSignal: Modbus
PROFIBUS
Data: PROFIBUS acc. to IEC 61158, RS-485 2-conductor
Serial transmission speed: ≤ 12 Mbps
Connection method: D-SUB-9, COMBICON
Transmission length: ≤ 1200 m (Depends on transmission speed and cable type)
Termination resistor: 390 Ω
220 Ω
390 Ω (Can be connected)
Single conductor/terminal point, rigid: 0.2 mm² ... 1.5 mm²
Single-wire/terminal point, flexible: 0.2 mm² ... 1.5 mm²
Max. AWG conductor cross section, flexible: 16
Min. AWG conductor cross section, flexible: 24
Single-wire/terminal point, rigid AWG max.: 16
Single-wire/terminal point, rigid AWG min.: 24
Output nominal voltage: 5 VDC
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/f787fba948051a41ada3f71b5659f395/-S204x204-FJPG
Width: 22.5 mm
Height: 92 mm
Depth: 73 mm
Material specificationsMaterial: PA 6.6-FR
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -40°C ... 70°C
Ambient temperature (storage/transport): -40°C ... 85°C
Altitude: ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
≤ 2000 m (Restrictions for ATEX applications)
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Air pressure (operation): ≤ 80 kPa (When used in EX zone2)
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3 G Ex nA IIC T4 Gc X
Note: Please follow the special installation instructions in the documentation!
UL, USA/Canada
Identification: 508 Listed
Corrosive gas test
Identification: ISA-S71.04-1985 G3 Harsh Group A
EMC dataElectromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: ± 6 kV (Test Level 3)
Discharge in air: ± 8 kV (Test Level 3)
Indirect discharge: ± 6 kV
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 3 GHz (Test Level 3)
Field intensity: 10 V/m
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: ± 2.2 kV (Test Level 3)
Signal: ± 2.2 kV (Test Level 3)
Comments: Criterion B
Surge current load (surge)
Standards/regulations: EN61000-4-5
Surge current load (surge)​
Input: ± 0.5 kV (sym./asym.)
Signal: ± 1 kV (Data line, asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V
Emitted interference
Standards/regulations: EN55011
Comments: Class A, industrial applications
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Standards and regulationsFree from substances that could impair the application of coating: in accordance with VW-AUDI-Seat central standard P-VW 3.10.7 57 65 0
MountingMounting type: DIN rail mounting
Technical Specs
ECLASSECLASS-11.0: 19070403
ECLASS-12.0: 19070403
ECLASS-13.0: 19070403
ETIMETIM 9.0: EC000448
UNSPSCUNSPSC 21.0: 32121600