Industrial Automation
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area Utilization restrictionâ CCCex note: Use in potentially explosive areas is not permitted in China. |
Product properties | IEC test classification: C2 Product type: Patch panel MTTF: 3281 Years (SN29500 standard, temperature25°C, operating cycle21%) 1245 Years (SN29500 standard, temperature40°C, operating cycle34.25%) 472 Years (SN29500 standard, temperature40°C, operating cycle100%) Insulation characteristics Overvoltage category: II Pollution degree: 2 |
Electrical properties | Electrical isolation: FE // Ethernet Maximum power dissipation for nominal condition: 0 W Rated insulation voltage: 85 VDC Supply Supply voltage range: 36 VDC ... 52 VDC ±10% (via PoE) 42 VDC ... 57 VDC (in acc. with UL) Function Designation: Shield current monitoring Switch-on threshold: ⥠30 mA Local diagnostics: Yellow LED Precision: ± 5 % Response time: 3 s Current: ⤠1.5 A Power consumption: 270 mW (Shield current monitoring) Impedance: ⤠1 é Voltage: ⤠10 V |
Interfaces | Data: Ethernet interface, 10/100/1000Base-T(X) in accordance with IEEE802.3 Serial transmission speed: 10/100/1000 Mbps Frequency range: 125 MHz Connection method: IDC connection Pin assignment: 1:1 Transmission length: 100 m (including patch cables) Single conductor/terminal point, rigid: 0.14 mm² ... 0.34 mm² Single-wire/terminal point, flexible: 0.14 mm² ... 0.34 mm² Max. AWG conductor cross section, flexible: 22 Min. AWG conductor cross section, flexible: 26 Single-wire/terminal point, rigid AWG max.: 22 Single-wire/terminal point, rigid AWG min.: 26 Wire diameter incl. insulation: 1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request) Frequency of connections between conductors of the same cross section: 10 Transmission medium: Copper Maximum output power: 60 W Maximum output current: 725 mA (PoE) Current carrying capacity: ⤠1.5 A (⤠60 W (PoE+)) Data: Ethernet interface, 10/100/1000Base-T(X) in accordance with IEEE802.3â Connection method: RJ45 jack |
Signaling | Optical representation: Yellow LED |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/c2c04032133b9b48883596b0703f60a6/-S204x204-FJPG Width: 23.8 mm Height: 101.3 mm Depth: 86 mm |
Material specifications | Material: Plastic Flammability rating according to UL 94: V0 |
Cable/line | External cable diameter (): 5.5 mm ... 6.5 mm |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (Manufacturer's declaration) Ambient temperature (operation): -40°C ... 75°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠5000 m (For restrictions, see the manufacturer's declaration for altitude operation) ⤠2000 m (Restrictions for ATEX applications) Permissible humidity (operation): 10 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant ATEX Identification: ï II 3 G Ex nA nC IIC T4 Gc X Note: Please follow the special installation instructions in the documentation! UL, USA/Canada Identification: Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 Class I, Div. 2, Groups A, B, C, D UL, USA Certificate: UL60079-0 Ed.6 / UL60079-15 Ed.4 UL, Canada Certificate: CSA22.2 No.60079-0 Ed.3 / CSA22.2 No.60079-15:16 Corrosive gas test Identification: ISA-S71.04-1985 G3 Harsh Group A Shipbuilding Identification: DNV GL DNV GL data Temperature: D Humidity: B Vibration: B EMC: B |
EMC data | Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU FCC Part15B ClassA CISPR22 Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: ± 6 kV (Test Level 3) Discharge in air: ± 8 kV (Test Level 3) Indirect discharge: ± 6 kV Comments: Criterion B Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 3 GHz (Test Level 3) Field intensity: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: ± 2.2 kV (1minute) Signal: ± 2.2 kV (1minute) Comments: Criterion B Surge current load (surge) Standards/regulations: EN61000-4-5 Surge current load (surge)â Input: ± 0.5 kV Signal: ± 1 kV (Data line, asymmetrical) Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V Emitted interference Standards/regulations: EN61000-6-4 Comments: Class A, industrial applications Emitted interferenceâ Standards/regulations: EN61000-6-3 Comments: Class B, domain of use: residential and small commercial Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and regulations | Standards/regulations: DINEN61643-21 |
Mounting | Mounting type: DIN rail mounting, stationary |
ECLASS | ECLASS-11.0: 19170112 ECLASS-12.0: 19170112 ECLASS-13.0: 19170112 |
ETIM | ETIM 9.0: EC002697 |
UNSPSC | UNSPSC 21.0: 43223300 |