PWT 100-800AC-FM - Lightning/surge arrester type 1/2

Lightning/surge arrester, according to type 1/2 / class I/II, for 3-phase power supply networks with combined PE and N installed in one conductor (L1, L2, L3, PEN).
Product Code: 2800531
Partner cod.: 2800531
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Download
Tecnichal data
NotesGeneral
Note: Assembling: Two 8 mm screws with 8 Nm on an isolated or grounded surface
Long-wave surge current 2 ms in accordance with IEC 60099-4: 250 x 1.0 kA; 500 x 0.5 kA.
Product propertiesIEC test classification: I / II
T1 / T2
EN type: T1 / T2
IEC power supply system: TN-C
IT
Type: Installation module
Product type: Arrester combination
Product family: POWERTRAB
Number of positions: 3
Surge protection fault message: Optical, remote indicator contact
Insulation characteristics
Overvoltage category: 8kV: IV (600V), III (1000V)
Pollution degree: 3
Electrical propertiesNominal frequency fN: 50 Hz (60Hz)
Nominal voltage UN: 690 VAC
Indicator/remote signaling
Connection name: Remote fault indicator contact
Switching function: 2x N/C contacts, 1-pos.
Operating voltage: 30 VAC
30 VDC
Operating current: 1.5 A AC
1.5 ADC
Supply: Status indicator/remote signaling
Operating voltage: 19.2 V AC/DC ... 30 V AC/DC
Operating current: 7 mA AC/DC ... 13 mA AC/DC
Rated current: 10 mA AC/DC
Max. required back-up fuse: 1 A (e.g. T to IEC 127-2/III)
Immunity to interference according to IEC 61000-4-5 (line-line): 1 kV
Immunity to interference according to IEC 61000-4-5 (line-earth): 6 kV
Connection dataDouble terminal point
Connection method: Screw connection
Screw thread: M6
Tightening torque: 8.5 Nm
Stripping length: 24 mm
Conductor cross section flexible: 16 mm² ... 50 mm²
Conductor cross section rigid: 16 mm² ... 50 mm²
Conductor cross section AWG: 6 ... 1/0
PE conductor connection
Connection method: Ring cable lug
Tightening torque: 20 Nm
Conductor cross section flexible: 16 mm² ... 95 mm²
Conductor cross section rigid: 16 mm² ... 95 mm²
Conductor cross section AWG: 6 ... 3/0
Remote fault indicator contact
Screw thread: M3
Tightening torque: 0.55 Nm
Stripping length: 7 mm
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/d478abc62565034d8afb85e93927169f/-S204x204-FJPG
Width: 176 mm
Height: 191 mm
Depth: 280 mm
Horizontal pitch: 10 Div.
Material specificationsColor: Silver
Flammability rating according to UL 94: V-2
CTI value of material: 600
250
Insulating material: PA/PC
Material group: I (PA 6.6/PC)
IIIa (PA 4.6)
Housing surface material: die-cast aluminum
Housing material: Die-cast aluminum, salt water resistant
Mechanical propertiesMechanical data
Open side panel: No
Protective circuitMode of protection: L-PE
Direction of action: 3L-PEN
Nominal voltage UN: 690VAC
554/960VAC (TN-C)
690VAC (IT)
Nominal frequency fN: 50 Hz (60Hz)
Maximum continuous operating voltage UC (L-PE): 800 VAC
Rated load current IL: 150 A (Serial through wiring with 50 mm²)
Residual current IPE: ≤ 20 µA
Standby power consumption PC: ≤ 48 mVA
Nominal discharge current In (8/20) µs (L-PE): 35 kA
Maximum discharge current Imax (8/20) µs (L-PE): 100 kA
Impulse discharge current (10/350) µs (L-PE), charge: 17.5 As
Impulse discharge current (10/350)µs (L-PE), specific energy: 305 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp: 35 kA
Total discharge current Itotal (10/350)µs: 100 kA
Follow current interrupt rating Ifi (L-PE): 50 kA
Short-circuit current rating ISCCR: 50 kA
Voltage protection level Up (L-PE): ≤ 4.5 kV
Residual voltage Ures (L-PE): ≤ 2.7 kV (at In)
≤ 2.5 kV (at 20 kA)
≤ 2.3 kV (at 10 kA)
≤ 2.2 kV (at 5 kA)
≤ 2.1 kV (at 3kA)
TOV behavior at UT (L-PE): 1960 VAC (200ms / withstand mode)
1500 VAC (5s / withstand mode)
Response time tA (L-PE): ≤ 100 ns
Max. backup fuse with V-type through wiring: 125 A (gG at ≥35 mm²)
Max. backup fuse with branch wiring: 400 A (gG at 2x 50 mm²)
800 A (aR (only up to Iimp = 25 kA))
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (only when all terminal points are used)
Ambient temperature (operation): -40°C ... 80°C
-40°C ... 55°C (serial through wiring ≥35mm²)
Ambient temperature (storage/transport): -40°C ... 80°C
Altitude: ≤ 4000 m (amsl)
Permissible humidity (operation): 5 % ... 95 %
Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation): 5g (10 ... 150 Hz / 2.5 h / X, Y, Z)
4g (5 ... 100 Hz / X, Y, Z - according to GL )
ApprovalsUL specifications
Maximum continuous operating voltage MCOV (L-L): 800 VAC
Maximum continuous operating voltage MCOV (L-G): 800 VAC
Nominal discharge current In (L-L): 20 kA
Nominal discharge current In (L-G): 20 kA
Mode of protection: L-L
L-G
Nominal voltage: 690VAC
400VAC
Power distribution system: Wye
Delta
Nominal frequency: 60 Hz
Measured limiting voltage MLV (L-L): 8750 V
Measured limiting voltage MLV (L-G): 4370 V
SPD Type: 4CA
UL indicator/remote signaling
Operating voltage: 30 VAC
DC operating voltage: 30 VDC
AC operating current: 1.5 A AC
DC operating current: 1.5 ADC
UL connection data Double terminal point
Tightening torque: 75 lbf-in.
Conductor cross section AWG: 1/0 ... 6
UL connection data PE conductor connection
Tightening torque: 175 lbf-in.
Conductor cross section AWG: 3/0
Standards and regulationsAir clearances and creepage distances
Standards/regulations: DINEN60664-1 / EN61643-11
Standards/specifications: IEC 61643-11
EN61643-11
Note: 2011
2012
MountingMounting type: Screw mounting
Technical Specs
ECLASSECLASS-11.0: 27130802
ECLASS-13.0: 27171201
ETIMETIM 9.0: EC000381
UNSPSCUNSPSC 21.0: 39121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00200.pdf

Flyer_00002.pdf

Flyer_00001.pdf

Manufacturer_declaration_00608.pdf

Manufacturer_declaration_02055.pdf

Manufacturer_declaration_14959.pdf

Package_slip_00429.pdf