Industrial Automation
VAL-CP-350-ST - Type 2 surge protection plug
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Product properties | IEC test classification: II T2 EN type: T2 IEC power supply system: TN TT Type: DIN rail module, two-section, divisible Product type: Replacement plug Number of positions: 1 Surge protection fault message: optical Insulation characteristics Overvoltage category: III Pollution degree: 2 |
Electrical properties | Nominal frequency fN: 50 Hz (60Hz) |
Connection data | Connection method: pluggable |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/7223de15cef3d94b83d8e68013f32ea5/-S204x204-FJPG Width: 11.7 mm Height: 46.4 mm Depth: 56.4 mm Horizontal pitch: 0.6 Div. |
Material specifications | Flammability rating according to UL 94: V-0 CTI value of material: 600 Insulating material: PBT-FR Material group: I Housing material: PBT-FR |
Protective circuit | Mode of protection: L-N L-PEN Direction of action: L-N / L-PEN Nominal voltage UN: 240VAC (TN) 240VAC (TT) Nominal frequency fN: 50 Hz (60Hz) Maximum continuous voltage UC: 350 VAC Nominal discharge current In (8/20) µs: 20 kA Maximum discharge current Imax (8/20) µs: 40 kA Short-circuit current rating ISCCR: 25 kA Voltage protection level Up: ⤠1.5 kV Residual voltage Ures: ⤠1.5 kV (at In) ⤠1.3 kV (at 10 kA) ⤠1.2 kV (at 5 kA) ⤠1.1 kV (at 4 kA) ⤠1 kV (at 2 kA) TOV behavior at UT: 415 VAC (5s / withstand mode) 440 VAC (120min / safe failure mode) Response time tA: ⤠25 ns Max. backup fuse with branch wiring: 315 A (gG) |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -40°C ... 80°C Ambient temperature (storage/transport): -40°C ... 80°C Altitude: ⤠2000 m (amsl) Permissible humidity (operation): 5 % ... 95 % Shock (operation): 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
Approvals | UL specifications Maximum continuous operating voltage MCOV (L-N): 350 VAC Nominal discharge current In (L-N): 20 kA Mode of protection: L-N Nominal voltage: 277VAC Power distribution system: Single phase Nominal frequency: 50/60 Hz Measured limiting voltage MLV (L-N): 2000 V SPD Type: 4CA |
Standards and regulations | Standards/specifications: IEC 61643-11 EN61643-11 Note: 2011 2012 |
Mounting | Mounting type: on base element |
ECLASS | ECLASS-11.0: 27130890 ECLASS-13.0: 27171292 |
ETIM | ETIM 9.0: EC002496 |
UNSPSC | UNSPSC 21.0: 39121600 |
Description other products