Industrial Automation
TRIO-PS/1AC/24DC/ 5 - Power supply unit
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Input data | AC operation Nominal input voltage range: 100 VAC ... 240 VAC Input voltage range: 85 VAC ... 264 VAC (Derating < 90 V AC: 2,5 %/V) Derating: < 90 VAC (2.5%/V) Input voltage range AC: 85 VAC ... 264 VAC (Derating < 90 V AC: 2,5 %/V) Electric strength, max.: 300 VAC Voltage type of supply voltage: AC Inrush current: < 15 A Inrush current integral (I2t): 1.1 A2s AC frequency range: 45 Hz ... 65 Hz Mains buffering time: > 20 ms (120VAC) > 110 ms (230 V AC) Current consumption: 1.65 A (120VAC) 0.9 A (230 V AC) Nominal power consumption: 189 VA Protective circuit: Transient surge protection; Varistor Power factor (cos phi): 0.72 Typical response time: < 1 s Input fuse: 3.15 A (slow-blow, internal) Permissible backup fuse: B6 B10 B16 Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K) Discharge current to PE: < 3.5 mA |
Output data | Efficiency: 89 % (for 230 V AC and nominal values) Output characteristic: U/I Nominal output voltage: 24 VDC ±1% Setting range of the output voltage (USet): 22.5 VDC ... 29.5 VDC (> 24 VDC, constant capacity restricted) Nominal output current (IN): 5 A (UOUT = 24 V DC) Derating: 55°C ... 70°C (2.5%/K) Feedback voltage resistance: 35 VDC Protection against overvoltage at the output (OVP): < 35 VDC Max. capacitive load: unlimited Active current limitation: approx. 10A (for short-circuit) Control deviation: < 1 % (change in load, static 10 % ... 90 %) < 2 % (change in load, dynamic 10 % ... 90 %) < 0.1 % (change in input voltage ±10 %) Residual ripple: < 20 mVPP Output power: 120 W Peak switching voltages nominal load: < 30 mVPP Maximum no-load power dissipation: 1.1 W Power loss nominal load max.: 18 W Rise time: < 2 ms (UOUT (10 % ... 90 %)) Connection in parallel: yes, for redundancy and increased capacity Connection in series: yes |
Connection data | Input Connection method: Screw connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 14 Stripping length: 9 mm Screw thread: M2,5 Tightening torque, min: 0.4 Nm Tightening torque max: 0.5 Nm Output Connection method: Screw connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 14 Stripping length: 9 mm Screw thread: M2,5 Tightening torque, min: 0.4 Nm Tightening torque max: 0.5 Nm |
Signaling | Types of signaling: LED Operating voltage display: Green LED Signal output Status display: "DC OK" LED green Note on status display: UOUT > 21.5 V: LED lights up |
Electrical properties | Insulation voltage input/output: 4 kV AC (type test) 2 kV AC (routine test) Insulation voltage output / PE: 500 VDC (type test) Insulation voltage input / PE: 2 kV AC (type test) 2 kV AC (routine test) |
Product properties | Product type: Power supply Product family: TRIO POWER MTBF (IEC 61709, SN 29500): > 2031000 h Insulation characteristics Protection class: I (with PE connection) Overvoltage category: III Degree of pollution: 2 |
Dimensions | Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/fecc2450a16fa84a8e25d1ee1b8e7ae1/-S204x204-FJPG Width: 40 mm Height: 130 mm Depth: 115 mm Installation dimensions Installation distance right/left: 0 mm / 0 mm Installation distance top/bottom: 50 mm / 50 mm |
Mounting | Mounting type: DIN rail mounting Assembly instructions: alignable: horizontally 0mm, vertically 50mm Mounting position: horizontal DIN rail NS 35, EN 60715 With protective coating: No |
Material specifications | Housing material: Metal Type of housing: Steel sheet, zinc-plated Side element version: Aluminum |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (> 55° C derating : 2.5%/K) Ambient temperature (storage/transport): -40°C ... 85°C Climatic class: 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation): ⤠95 % (at 25°C, non-condensing) Shock: 15g in all directions in acc. with IEC 60068-2-27 Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and regulations | Standard â Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV) Standard â Limitation of mains harmonic currents: EN61000-3-2 Standard - Electrical safety: EN60950-1/VDE0805 (SELV) Standard â Protection against shock currents, basic requirements for protective separation in electrical equipment: EN50178 Standard â Safety extra-low voltage: EN60950-1 (SELV) EN60204 (PELV) Standard - Safe isolation: DINVDE0100-410 |
Approvals | Shipbuilding approval: DNVGL(EMCA) UL approvals: UL/C-UL listed UL508 UL/C-UL Recognized UL60950-1 Conformity/Approvals SIL in accordance with IEC 61508: 0 |
EMC data | Low Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC EMC requirements for noise emission: EN61000-6-3 EN61000-6-4 EMC requirements for noise immunity: EN61000-6-1 EN61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: 8 kV (Test Level 4) Discharge in air: 8 kV (Test Level 3) Comments: Criterion A Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 2 GHz 2 GHz ... 3 GHz Test field strength: 10 V/m Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 4 kV (Test Level 4 - asymmetrical) Output: 4 kV (Test Level 4 - asymmetrical) Signal: 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: EN61000-4-5 Input: 2 kV (Test Level 3 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ Frequency range: 10 kHz ... 15 kHz Comments: Criterion A Voltage: 3 V (Test Level 2) Conducted interferenceââ Frequency range: 10 kHz ... 15 kHz Comments: Criterion A Voltage: 3 V (Test Level 2) Voltage dips Standards/regulations: EN61000-4-11 Emitted interference Standards/regulations: EN61000-6-3 Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassB, area of application: Industry and residential Emitted radio interference in acc. with EN 55011: EN 55011 (EN 55022) Class B, area of application: Industry and residential |
ECLASS | ECLASS-11.0: 27040701 ECLASS-12.0: 27040701 ECLASS-13.0: 27040701 |
ETIM | ETIM 8.0: EC002540 |
UNSPSC | UNSPSC 21.0: 39121000 |
Description other products