Industrial Automation
MINI MCR-2-UI-I-OLP - Loop-powered isolators
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
![](https://www.technologybsa.com/wp-content/uploads/2023/08/copia.png)
Notes | Utilization restriction EMC note: EMC: class A product, see manufacturer's declaration in the download area |
Product properties | Product type: Signal conditioner Product family: MINI Analog Pro No. of channels: 1 Type: Signal conditioner Configuration: DIP switches Insulation characteristics: GBStandard Overvoltage category: II Pollution degree: 2 |
Electrical properties | No. of channels: 1 Electrical isolation: 2-way isolation Electrical isolation between input and output: yes Limit frequency (3 dB): approx. 30 Hz Step response (10-90%): 20 ms Maximum temperature coefficient: 0.01 %/K Temperature coefficient, typical: 0.005 %/K Maximum transmission error: ⤠0.1 % (of final value) Electrical isolation Input/output/power supply Rated insulation voltage: 300 Vrms Test voltage: 3 kV AC (50Hz, 60s) Insulation: Reinforced insulation according to IEC/EN61010-1 Supply Supply voltage range: 8 VDC ... 30 VDC (loop-powered, no external supply necessary) Typical current consumption: ⤠20 mA Power consumption: ⤠600 mW |
Input data | Signal: Voltage/current Number of inputs: 1 Configurable/programmable: Yes Voltage input signal: 0 mV ... 1000 mV 0 mV ... 750 mV 0 mV ... 500 mV 0 mV ... 300 mV 0 mV ... 250 mV 0 mV ... 200 mV 0 mV ... 125 mV 0 mV ... 120 mV 0 mV ... 150 mV 0 mV ... 100 mV 0 mV ... 75 mV 0 mV ... 60 mV 0 mV ... 50 mV 0 V ... 10 V 0 V ... 7.5 V 0 V ... 5 V 0 V ... 3 V 0 V ... 2.5 V 0 V ... 2 V 0 V ... 1.5 V 0 V ... 1.25 V 0 V ... 1.2 V 0 V ... 30 V 0 V ... 25 V 0 V ... 20 V 0 V ... 12.5 V 0 V ... 12 V 0 V ... 15 V -1000 mV ... 1000 mV -750 mV ... 750 mV -500 mV ... 500 mV -300 mV ... 300 mV -250 mV ... 250 mV -200 mV ... 200 mV -125 mV ... 125 mV -120 mV ... 120 mV -150 mV ... 150 mV -100 mV ... 100 mV -75 mV ... 75 mV -60 mV ... 60 mV -50 mV ... 50 mV -10 V ... 10 V -7.5 V ... 7.5 V -5 V ... 5 V -3 V ... 3 V -2.5 V ... 2.5 V -2 V ... 2 V -1.25 V ... 1.25 V -1.2 V ... 1.2 V -1.5 V ... 1.5 V -30 V ... 30 V -25 V ... 25 V -20 V ... 20 V -12.5 V ... 12.5 V -12 V ... 12 V -15 V ... 15 V 2 V ... 10 V (additional areas can be configured, see table) 1 V ... 5 V (additional areas can be configured, see table) Max. voltage input signal: < 30 V Current input signal: 0 mA ... 40 mA 0 mA ... 30 mA 0 mA ... 20 mA 0 mA ... 12 mA 0 mA ... 10 mA 0 mA ... 8 mA 0 mA ... 7.5 mA 0 mA ... 6 mA 0 mA ... 5 mA 0 mA ... 4 mA 0 mA ... 3 mA 0 mA ... 2.5 mA 0 mA ... 2 mA 4 mA ... 20 mA 2 mA ... 10 mA 1 mA ... 5 mA Max. current input signal: 50 mA (Dielectric strength up to 30 V) Input resistance of voltage input: ï» 100 ké (â¤1V) ï» 1 Mé (⥠1 V) Input resistance current input: 25 é (+0.7V for test diode) |
Output data | Signal: Current Number of outputs: 1 Current output signal: 4 mA ... 20 mA Max. current output signal: 32 mA Load/output load current output: < 1000 é ((UB - 8V) / 22mA) Ripple: < 10 mVrms (at 600 é) |
Connection data | Connection method: Screw connection Stripping length: 10 mm Screw thread: M3 Conductor cross section rigid: 0.2 mm² ... 1.5 mm² (with ferrule) 0.14 mm² ... 2.5 mm² (without ferrule) Conductor cross section flexible: 0.14 mm² ... 2.5 mm² Conductor cross section AWG: 24 ... 12 (flexible) Tightening torque: 0.5 Nm ... 0.6 Nm |
Ex data | Ex installation (EPL): Gc Div.2 |
Signaling | Status display: Green LED (supply voltage) |
Dimensions | Width: 6.2 mm Height: 109.81 mm Depth: 119.2 mm |
Material specifications | Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 2 Housing material: PBT |
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 (not assessed by UL) Ambient temperature (operation): -40°C ... 70°C Ambient temperature (storage/transport): -40°C ... 85°C Altitude: ⤠2000 m Permissible humidity (operation): 5 % ... 95 % (non-condensing) |
Approvals | CE Certificate: CE-compliant ATEX Identification: ï II 3 G Ex ec IIC T4 Gc Certificate: BVS 19 ATEX E 079 X UKCAEx(UKEX) Identification: ï II 3 G Ex ec IIC T4 Gc Certificate: PxCIF21UKEX2901994X IECEx Identification: Ex ec IIC T4 Gc Certificate: IECEx BVS 19.0068X CCC/China-Ex Identification: Ex nA IIC T4 Gc UL, USA/Canada Identification: UL508 Listed Class I, Div. 2, Groups A, B, C, D T5 Class I, Zone 2, Group IIC T5 Shipbuilding approval Certificate: DNV GL TAA000021E Rev. 1 EACEx Identification: ï 2Ex ec IIC T4 Gc Certificate: BY/112 02.01 TP012 103.01 00081 DNV GL data Temperature: B Humidity: B Vibration: A EMC: A Enclosure: Required protection according to the Rules shall be provided upon installation on board |
EMC data | Noise immunity: EN 61000-6-2 Note: When being exposed to interference, there may be minimal deviations. Electromagnetic compatibility: Conformance with EMC directive Noise emission: EN 61000-6-4 |
Standards and regulations | Electrical isolation: 2-way isolation GBStandard Standards/regulations: GB3836.1 GB3836.8 |
Mounting | Mounting type: DIN rail mounting Mounting position: any |
ECLASS | ECLASS-11.0: 27210120 ECLASS-12.0: 27210120 ECLASS-13.0: 27210120 |
ETIM | ETIM 9.0: EC002653 |
UNSPSC | UNSPSC 21.0: 39121000 |
Description other products